<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0001-6365</journal-id>
<journal-title><![CDATA[Acta Odontológica Venezolana]]></journal-title>
<abbrev-journal-title><![CDATA[Acta odontol.venez]]></abbrev-journal-title>
<issn>0001-6365</issn>
<publisher>
<publisher-name><![CDATA[Facultad de Odontología -UCV]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0001-63652007000100005</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Análisis de la eficacia de agentes químicos de desinfección en materiales elastoméricos]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ribeiro da Cunha Peixoto]]></surname>
<given-names><![CDATA[Rogéli Tibúrcio]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Haueisen Sander]]></surname>
<given-names><![CDATA[Herbert]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Amêndola Couto]]></surname>
<given-names><![CDATA[Paulo Henrique]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Martins Diniz]]></surname>
<given-names><![CDATA[Leandro]]></given-names>
</name>
<xref ref-type="aff" rid="A04"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Valente Araújo]]></surname>
<given-names><![CDATA[Patrícia]]></given-names>
</name>
<xref ref-type="aff" rid="A05"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodrigues Santos]]></surname>
<given-names><![CDATA[Vagner]]></given-names>
</name>
<xref ref-type="aff" rid="A06"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Thadeu de Abreu Poletto]]></surname>
<given-names><![CDATA[Luiz]]></given-names>
</name>
<xref ref-type="aff" rid="A07"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Facultad de Odontología de UFMG  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Facultad de Odontología de UFMG  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A03">
<institution><![CDATA[,Facultad de Odontología de UFMG  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A04">
<institution><![CDATA[,Facultad de Odontología de UFMG  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A05">
<institution><![CDATA[,Facultad de Odontología de UFMG  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A06">
<institution><![CDATA[,Facultad de Odontología de UFMG  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A07">
<institution><![CDATA[,Facultad de Odontología de UFMG  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>01</month>
<year>2007</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>01</month>
<year>2007</year>
</pub-date>
<volume>45</volume>
<numero>1</numero>
<fpage>29</fpage>
<lpage>32</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_arttext&amp;pid=S0001-63652007000100005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_abstract&amp;pid=S0001-63652007000100005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_pdf&amp;pid=S0001-63652007000100005&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[El objetivo de este estudio fue evaluar la eficacia de agentes de desinfección indicados para polisulfuros (mercaptanos), poliéteres y siliconas por condensación y por adición. Fueron confeccionadas noventa muestras de cada material, siendo treinta de ellas contaminadas con Streptococcus mutans o Staphylococcus aureus o Candida albicans. De cada solución microbiana fueron retiradas diez muestras del polisulfeto y de ambas las siliconas, que fueron inmersas por diez minutos en glutaraldehído al 2% y otras diez inmersas en agua destilada estéril (controle negativo). Después de un nuevo lavado en agua destilada, las muestras fueron transferidas a medios de cultivo estériles. Las diez muestras restantes no fueron sometidas al agente de desinfección y fueron transferidas a medios asociados a agentes antimicrobianos específicos (control positivo). La turbidez de los medios de cultivo fue evaluada como indicativo del crecimiento microbiano siguiéndose a la incubación por 24 h a 37O C y se realizó la dilución y sembrado en placas de Petri para contar las colonias. Para el poliéter fue ejecutado el mismo procedimiento, pero el agente de desinfección usado fue el hipoclorito de sodio a 1%. No hubo turbidez comprobatoria del crecimiento microbiano en ninguno de los medios de cultivo que contenían los especimenes sometidos a los agentes de desinfección. Se concluyó que el glutaraldehído al 2% es un agente de desinfección eficaz para el polisulfuro y para las siliconas por adición y por condensación, así como el hipoclorito a 1% es eficaz para el poliéter, para los microorganismos evaluados.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The aim of this in vitro study was to evaluate the disinfection efficacy of elastomeric impression materials such as polysulfides, polyethers, condensation and addition silicones. Ninety samples of each material were made and every thirty samples contaminated with Streptococcus mutans or Staphylococcus aureus or Candida albicans. From each microbial solution there were taken ten samples of polysulfide and of both silicones which were immersed for ten minutes in a 2% glutaraldehyde solution and other ten immersed in sterile distilled water (negative control). After being washed again in distilled water, the samples were transferred to sterile culture medium. The last ten samples were not submitted to any disinfection agent and were transferred to mediums associated with specific anti-microbial agents (positive control). The turbidity of the culture mediums was evaluated as an indication of the microbial growth after a period of 24-hour incubation at 37oC and the dilution and seeding in Petri dishes were done to count the colonies. The same procedure was done for the polyether, but the disinfection agent used was 1% sodium hypoclorite. There was no proved turbidity of the microbial growth in any of the culture mediums which had samples submitted to the disinfection agents tested. It was concluded that the 2% glutaraldehyde is an effective disinfection agent to polysulfides and to both condensation and addition silicones, as well as 1% sodium hypoclorite is effective to polyether, for the tested microorganisms.]]></p></abstract>
<abstract abstract-type="short" xml:lang="pt"><p><![CDATA[O objetivo deste estudo in vitro foi avaliar a eficácia de agentes de desinfecção indicados para polissulfetos, poliéteres e siliconas de condensação e adição. Foram confeccionadas noventa amostras de cada material, sendo cada trinta contaminadas com Streptococcus mutans, Staphylococcus aureus ou Candida albicans. De cada solução microbiana foram retiradas dez amostras do polissulfeto e de ambas as siliconas, que foram imersas por dez minutos no glutaraldeído a 2% e outras dez imersas em água destilada estéril (controle negativo). Após nova lavagem em água destilada, as amostras foram transferidas para meios de cultura estéreis. As dez amostras restantes não foram submetidas ao agente de desinfecção e foram transferidas para meios associados a agentes antimicrobianos específicos (controle positivo). A turbidez dos meios de cultura foi avaliada como indicativo de crescimento microbiano após incubação por 24 h a 37O C e realizou-se a diluição e semeadura nas placas de Petri para contagem de colônias. Para o poliéter foi executado o mesmo procedimento, porém o agente de desinfecção empregado foi o hipoclorito de sódio a 1%. Não houve turvação comprobatória de crescimento bacteriano em nenhum dos meios da cultura que continham corpos de prova submetidos aos agentes de desinfecção. Concluiu-se que o glutaraldeído a 2% é um agente de desinfecção eficaz para o polissulfeto e para as siliconas por adição e por condensação, assim como o hipoclorito a 1% é eficaz para o poliéter, para os microorganismos testados.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[infección cruzada]]></kwd>
<kwd lng="es"><![CDATA[materiales de impresión]]></kwd>
<kwd lng="es"><![CDATA[agentes de desinfección]]></kwd>
<kwd lng="en"><![CDATA[cross-infection]]></kwd>
<kwd lng="en"><![CDATA[elastomeric impression materials]]></kwd>
<kwd lng="en"><![CDATA[disinfection agents]]></kwd>
<kwd lng="pt"><![CDATA[infecção cruzada]]></kwd>
<kwd lng="pt"><![CDATA[materiais de moldagem elastoméricos]]></kwd>
<kwd lng="pt"><![CDATA[agentes de desinfecção]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p style="line-height: 100%; word-spacing: 0" align="center"><b><span style="font-family: Verdana; mso-fareast-font-family: Times New Roman; mso-bidi-font-family: Times New Roman; mso-ansi-language: ES-VE; mso-fareast-language: PT-BR; mso-bidi-language: AR-SA" lang="ES-VE"><font size="3">Análisis de la eficacia de agentes químicos de desinfección en materiales elastoméricos</font></span></b></p>     <p style="line-height: 100%; word-spacing: 0" align="center">&nbsp;</p>     <p style="line-height: 100%; word-spacing: 0" align="center"><b><font face="Verdana" size="2">Rogéli Tibúrcio Ribeiro da Cunha Peixoto<sup>1, </sup></font><font face="Verdana" size="2">Herbert Haueisen Sander<sup>2</sup>,Paulo Henrique Amêndola Couto<sup>3</sup></font><font face="Verdana" size="2">,<sup> </sup>Leandro Martins Diniz<sup>4</sup>,Patrícia Valente Araújo<sup>5</sup>, </font><font face="Verdana" size="2">Vagner Rodrigues Santos<sup>6</sup> ,<sup> </sup>Luiz Thadeu de Abreu Poletto<sup>7</sup></font></b></p>     <p style="line-height: 100%; word-spacing: 0" align="center">&nbsp;</p>     <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2"><sup>1</sup> Profesora Asistente de la Facultad de Odontología de UFMG</font> <font face="Verdana" size="2">Alumna de Doctorado en Operatoria Dental por la Facultad de Odontología de UFMG&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </font></p>     <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2"><sup>2 </sup>Profesor Asistente de la Facultad de Odontología de UFMG</font> <font face="Verdana" size="2">Alumno de Doctorado en Operatoria Dental por la Facultad de Odontología de UFMG</font></p>     <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2"><sup>3</sup> Alumno de graduación del curso de Odontología de la Facultad de Odontología de UFMG</font></p>     <p style="line-height: 100%; word-spacing: 0" align="justify"><sup>4</sup><font face="Verdana" size="2"> Alumno de graduación del curso de Odontología de la Facultad de Odontología de UFMG</font></p>     <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2"><sup>5</sup> Magíster en Operatoria Dental por la Facultad de Odontología de UFMG</font></p>     <p style="line-height: 100%; word-spacing: 0; margin-right: 0cm" align="justify"><font face="Verdana" size="2"><sup>6</sup> Profesor Adjunto de la Facultad de Odontología de UFMG</font> <font face="Verdana" size="2">Doctor en Patología por la Facultad de Medicina de UFMG</font></p>     ]]></body>
<body><![CDATA[<p style="line-height: 100%; word-spacing: 0; margin-right: 0cm" align="justify"><font face="Verdana" size="2"><sup>7 </sup>Profesor Adjunto de la Facultad de Odontología de UFMG</font> <font face="Verdana" size="2">Doctor en Operatoria Dental por la Facultad de Odontología de Bauru – USP.</font></p>     <p style="line-height: 100%; word-spacing: 0; margin-right: 0cm" align="justify"><font face="Verdana" size="2">Universidad Federal de Minas Gerais, Facultad de Odontología, Departamento de Odontología Restauradora y Departamento de Clínica, Patología y Cirugía Odontológica.</font></p>     <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>RESUMEN</b></font></p>     <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">El objetivo de este estudio fue evaluar la eficacia de agentes de desinfección indicados para polisulfuros (mercaptanos), poliéteres y siliconas por condensación y por adición. Fueron confeccionadas noventa muestras de cada material, siendo treinta de ellas contaminadas con Streptococcus mutans o Staphylococcus aureus o Candida albicans. De cada solución microbiana fueron retiradas diez muestras del polisulfeto y de ambas las siliconas, que fueron inmersas por diez minutos en glutaraldehído al 2% y otras diez inmersas en agua destilada estéril (controle negativo). Después de un nuevo lavado en agua destilada, las muestras fueron transferidas a&nbsp; medios de cultivo estériles. Las diez muestras restantes no fueron sometidas al agente de desinfección y fueron transferidas a medios asociados a agentes antimicrobianos específicos (control positivo). La turbidez de los medios de cultivo fue evaluada como indicativo del crecimiento microbiano siguiéndose a la incubación por 24 h a 37O C y se realizó la dilución y sembrado en placas de Petri para contar las colonias. Para el poliéter fue ejecutado el mismo procedimiento, pero el agente de desinfección usado fue el hipoclorito de sodio a 1%. No hubo turbidez comprobatoria del crecimiento microbiano en ninguno de los medios de cultivo que contenían los especimenes sometidos a los agentes de desinfección. Se concluyó que el glutaraldehído al 2% es un agente de desinfección eficaz para el polisulfuro y para las siliconas por adición y por condensación, así como el hipoclorito a 1% es eficaz para el poliéter, para los microorganismos evaluados.</font></p>     <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>Palabras Claves:</b> infección cruzada, materiales de impresión, agentes de desinfección.</font></p>     <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>SUMMARY</b></font></p>     <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">The aim of this in vitro study was to evaluate the disinfection efficacy of elastomeric impression materials such as polysulfides, polyethers, condensation and addition silicones. Ninety samples of each material were made and every thirty samples contaminated with Streptococcus mutans or Staphylococcus aureus or Candida albicans. From each microbial solution there were taken ten samples of polysulfide and of both silicones which were immersed for ten minutes in a 2% glutaraldehyde solution and other ten immersed in sterile distilled water (negative control). After being washed again in distilled water, the samples were transferred to sterile culture medium. The last ten samples were not submitted to any disinfection agent and were transferred to mediums associated with specific anti-microbial agents (positive control). The turbidity of the culture mediums was evaluated as an indication of the microbial growth after a period of 24-hour incubation at 37oC and the dilution and seeding in Petri dishes were done to count the colonies. The same procedure was done for the polyether, but the disinfection agent used was 1% sodium hypoclorite. There was no proved turbidity of the microbial growth in any of the culture mediums which had samples submitted to the disinfection agents tested. It was concluded that the 2% glutaraldehyde is an effective disinfection agent to polysulfides and to both condensation and addition silicones, as well as 1% sodium hypoclorite is effective to polyether, for the tested microorganisms.</font></p>     <p style="line-height: 100%; tab-stops: 36.0pt 210.0pt; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>Key-words:</b> cross-infection; elastomeric impression materials; disinfection agents</font></p>     <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>RESUMO</b></font></p>     <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">O objetivo deste estudo in vitro foi avaliar a eficácia de agentes de desinfecção indicados para polissulfetos, poliéteres e siliconas de condensação e adição. Foram confeccionadas noventa amostras de cada material, sendo cada trinta contaminadas com Streptococcus mutans, Staphylococcus aureus ou Candida albicans. De cada solução microbiana foram retiradas dez amostras do polissulfeto e de ambas as siliconas, que foram imersas por dez minutos no glutaraldeído a 2% e outras dez imersas em água destilada estéril (controle negativo). Após nova lavagem em água destilada, as amostras foram transferidas para meios de cultura estéreis. As dez amostras restantes não foram submetidas ao agente de desinfecção e foram transferidas para meios associados a agentes antimicrobianos específicos (controle positivo). A turbidez dos meios de cultura foi avaliada como indicativo de crescimento microbiano após incubação por 24 h a 37O C e realizou-se a diluição e semeadura nas placas de Petri para contagem de colônias. Para o poliéter foi executado o mesmo procedimento, porém o agente de desinfecção empregado foi o hipoclorito de sódio a 1%. Não houve turvação comprobatória de crescimento bacteriano em nenhum dos meios da cultura que continham corpos de prova submetidos aos agentes de desinfecção. Concluiu-se que o glutaraldeído a 2% é um agente de desinfecção eficaz para o polissulfeto e para as siliconas por adição e por condensação, assim como o hipoclorito a 1% é eficaz para o poliéter, para os microorganismos testados.</font></p>     ]]></body>
<body><![CDATA[<p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>Palavras-Chave:</b> infecção cruzada, materiais de moldagem elastoméricos, agentes de desinfecção.</font></p>     <p align="justify" style="line-height: 100%; word-spacing: 0"><font face="Verdana" size="2"><b>Recibido para arbitraje:</b> 08/08/2005&nbsp; <b>Aceptado para publicación:</b> 13/10/2005</font></p>     <p style="line-height: 100%; tab-stops: 36.0pt 210.0pt; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>INTRODUCCIÓN</b></font></p>     <p style="line-height: 100%; tab-stops: 36.0pt 210.0pt; word-spacing: 0" align="justify"><font face="Verdana" size="2">El contacto con materiales de impresión contaminados es una posible vía de infección cruzada en Odontología (1). Una vez que la esterilización de materiales de impresión es un procedimiento que consume mucho tiempo y puede ser prejudicial al material, que necesita mantener su estabilidad dimensional, la desinfección de la superficie de las impresiones obtenidas con estos materiales a través de productos químicos específicos parece ser la más adecuada en la rutina clínica.</font></p>     <p style="line-height: 100%; tab-stops: 36.0pt 210.0pt; word-spacing: 0" align="justify"><font face="Verdana" size="2">Sabiendo que la superficie y el interior de los moldes pueden contener microorganismos que sobreviven por largos períodos de tiempo lejos de sus hábitat naturales (2), órganos internacionales como la Asociación Dental Americana (ADA), Federación Dentaria Internacional (FDI) y Asociación Dental Británica (BDA) recomiendan que materiales de impresión deban ser sometidos a desinfección antes que hayan sido enviados al laboratorio (3). El lavado con agua tiene la función de remover la materia orgánica y disminuir el número de microorganismos presentes en el material de impresión. Sin embargo, este procedimiento no dispensa la desinfección de los moldes, por ser ineficaz para la eliminación completa de todos los microorganismos (4). Diferentes agentes químicos han sido indicados para desinfección de materiales elastoméricos, tales como clorhexidina (5), hipoclorito de sodio (6,7), glutaraldehído (6,8,9) e yodoformos (6,9).</font></p>     <p style="line-height: 100%; tab-stops: 36.0pt 210.0pt; word-spacing: 0" align="justify"><font face="Verdana" size="2">Así como el Ministerio de la Salud de Brasil, la Comisión Permanente de Bio-seguridad de la Facultad de Odontología de UFMG (10) preconiza que la desinfección de materiales de impresión como los polisulfuros y siliconas, sean ellos por adición o por condensación, deba ser realizada pela inmersión del molde por 10 min en glutaraldehído al 2%. Para los poliéteres, el protocolo de desinfección consiste en la inmersión del molde en hipoclorito de sodio a 1%, también por 10 min. Así, el objetivo de ese estudio fue evaluar la eficacia del glutaraldehído al 2% en la desinfección de un polisulfuro, de una silicona por adición y de una silicona por condensación, además del hipoclorito de sodio a 1% en la desinfección de un poliéter, contaminados con Staphylococcus aureus, Streptococcus mutans o Candida albicans.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>MATERIAL Y MÉTODOS</b></font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>1. Muestras microbiológicas</b></font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">Se utilizaron muestras de cultivos puros de Streptococcus mutans (ATCC 70069), Staphylococcus aureus (ATCC 12692) y Candida albicans (ATCC 18804), mantenidas en caldo de Tripticase-soya a 35o C/37o C, durante 24 h.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>2. Materiales de impresión</b></font></p>     ]]></body>
<body><![CDATA[<p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">Los materiales de impresión utilizados están listados en el <a href="#cuad1">CUADRO 1</a>.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><a name="cuad1"></a></p>     <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2"><b>CUADRO 1</b></font></p>     <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2"><b>Materiales de impresión elastoméricos utilizados</b></font></p>     <div align="center">       <center>   <table border="1" cellspacing="1" style="border-collapse: collapse; mso-table-layout-alt: fixed; mso-border-top-alt: solid windowtext 1.5pt; mso-border-bottom-alt: solid windowtext 1.5pt; mso-padding-alt: 0cm 3.5pt 0cm 3.5pt; border-style: none; border-width: medium; margin-left: 3.5pt" width="550" height="122">     <tr>       <td width="192" valign="top" style="width: 143.85pt; border-left-style: none; border-left-width: medium; border-right: .25pt solid windowtext; border-top: 1.5pt solid windowtext; border-bottom: .25pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" align="center" height="16">             <p style="line-height: 100%; word-spacing: 0" align="left"><font face="Verdana" size="2"><b>Tipo</b></font></td>       <td width="304" valign="top" style="width: 228.15pt; mso-border-left-alt: solid windowtext .25pt; border-left-style: none; border-left-width: medium; border-right: .25pt solid windowtext; border-top: 1.5pt solid windowtext; border-bottom: .25pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" align="center" height="16">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2"><b>Marca         comercial</b></font></p>       </td>       <td width="200" valign="top" style="width: 150.0pt; mso-border-left-alt: solid windowtext .25pt; border-left-style: none; border-left-width: medium; border-right-style: none; border-right-width: medium; border-top: 1.5pt solid windowtext; border-bottom: .25pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" align="center" height="16">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2"><b>Fabricante</b></font></p>       </td>     </tr>     <tr>       <td width="192" valign="top" style="width: 143.85pt; mso-border-top-alt: solid windowtext .25pt; border-left-style: none; border-left-width: medium; border-right: .25pt solid windowtext; border-top-style: none; border-top-width: medium; border-bottom: .25pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" height="12">             <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">Poliéter</font></p>       </td>       <td width="304" valign="top" style="width: 228.15pt; mso-border-top-alt: solid windowtext .25pt; mso-border-left-alt: solid windowtext .25pt; border-left-style: none; border-left-width: medium; border-right: .25pt solid windowtext; border-top-style: none; border-top-width: medium; border-bottom: .25pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" height="12">             ]]></body>
<body><![CDATA[<p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Impregum         Soft<sup>®</sup></font></p>       </td>       <td width="200" valign="top" style="width: 150.0pt; mso-border-top-alt: solid windowtext .25pt; mso-border-left-alt: solid windowtext .25pt; border-left-style: none; border-left-width: medium; border-right-style: none; border-right-width: medium; border-top-style: none; border-top-width: medium; border-bottom: .25pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" height="12">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">3MEspe</font></p>       </td>     </tr>     <tr>       <td width="192" valign="top" style="width: 143.85pt; mso-border-top-alt: solid windowtext .25pt; border-left-style: none; border-left-width: medium; border-right: .25pt solid windowtext; border-top-style: none; border-top-width: medium; border-bottom: .25pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" height="15">             <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">Polisulfuro</font></p>       </td>       <td width="304" valign="top" style="width: 228.15pt; mso-border-top-alt: solid windowtext .25pt; mso-border-left-alt: solid windowtext .25pt; border-left-style: none; border-left-width: medium; border-right: .25pt solid windowtext; border-top-style: none; border-top-width: medium; border-bottom: .25pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" height="15">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Permlastic<sup>®</sup></font></p>       </td>       <td width="200" valign="top" style="width: 150.0pt; mso-border-top-alt: solid windowtext .25pt; mso-border-left-alt: solid windowtext .25pt; border-left-style: none; border-left-width: medium; border-right-style: none; border-right-width: medium; border-top-style: none; border-top-width: medium; border-bottom: .25pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" height="15">             <p style="tab-stops: 0cm center 50.5pt; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Kerr</font></p>       </td>     </tr>     <tr>       <td width="192" valign="top" style="width: 143.85pt; mso-border-top-alt: solid windowtext .25pt; border-left-style: none; border-left-width: medium; border-right: .25pt solid windowtext; border-top-style: none; border-top-width: medium; border-bottom: .25pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" height="15">             <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">Silicona         por adición</font></p>       </td>       <td width="304" valign="top" style="width: 228.15pt; mso-border-top-alt: solid windowtext .25pt; mso-border-left-alt: solid windowtext .25pt; border-left-style: none; border-left-width: medium; border-right: .25pt solid windowtext; border-top-style: none; border-top-width: medium; border-bottom: .25pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" height="15">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Addflow<sup>®</sup></font></p>       </td>       <td width="200" valign="top" style="width: 150.0pt; mso-border-top-alt: solid windowtext .25pt; mso-border-left-alt: solid windowtext .25pt; border-left-style: none; border-left-width: medium; border-right-style: none; border-right-width: medium; border-top-style: none; border-top-width: medium; border-bottom: .25pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" height="15">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">SS         White</font></p>       </td>     </tr>     <tr>       <td width="192" valign="top" style="width: 143.85pt; mso-border-top-alt: solid windowtext .25pt; border-left-style: none; border-left-width: medium; border-right: .25pt solid windowtext; border-top-style: none; border-top-width: medium; border-bottom: 1.5pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" height="34">             <p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">Silicona         por condensación</font></p>       </td>       <td width="304" valign="top" style="width: 228.15pt; mso-border-top-alt: solid windowtext .25pt; mso-border-left-alt: solid windowtext .25pt; border-left-style: none; border-left-width: medium; border-right: .25pt solid windowtext; border-top-style: none; border-top-width: medium; border-bottom: 1.5pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" height="34">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Oranwash<sup>®</sup></font></p>       </td>       <td width="200" valign="top" style="width: 150.0pt; mso-border-top-alt: solid windowtext .25pt; mso-border-left-alt: solid windowtext .25pt; border-left-style: none; border-left-width: medium; border-right-style: none; border-right-width: medium; border-top-style: none; border-top-width: medium; border-bottom: 1.5pt solid windowtext; padding-left: 3.5pt; padding-right: 3.5pt; padding-top: 0cm; padding-bottom: 0cm" height="34">             ]]></body>
<body><![CDATA[<p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Zhermack</font></p>       </td>     </tr>   </table>   </center> </div>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>3. Confección de las muestras</b></font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">Para la obtención de los especimenes de los materiales estudiados, han sido utilizadas cuatro matrices de plástico conteniendo diez depresiones prefabricadas, cada cual con 11 mm de diámetro y 6 mm de profundidad.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">Los cuatro materiales elastoméricos fueron proporcionados y manipulados de acuerdo con las instrucciones de sus respectivos fabricantes e inseridos en las matrices a través de jeringas. En total, fueron confeccionados noventa especímenes &nbsp;de cada material.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>4. Procedimientos microbiológicos</b></font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">Para cada material, las muestras fueron divididas en tres grupos, cada uno conteniendo treinta especímenes En ambiente aséptico (cámara de flujo laminar), estos fueran inmersos durante 60s en suspensiones microbianas de Streptococcus mutans, Staphylococcus aureus y Candida albicans, respectivamente. Diez especímenes de cada uno de los materiales fueron sometidos a uno de los siguientes procedimientos de desinfección listados en el <a href="#cuad2">CUADRO 2</a>. Otros diez especimenes de cada elastómero también fueron contaminados en uno de los tres cultivos, pero fueron inmersos en un Becker conteniendo agua destilada estéril, durante 10 min, los cuales sirvieron como controles negativos del experimento.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><a name="cuad2"></a></p>     <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2"><b>CUADRO 2</b></font></p>     <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2"><b>Procedimientos de desinfección de los materiales de impresión</b></font></p>     <div align="center">       ]]></body>
<body><![CDATA[<center>   <table border="1" cellspacing="1" style="margin-left:3.5pt;  border-collapse:collapse;mso-table-layout-alt:fixed;border:none;mso-border-top-alt:  solid windowtext 1.5pt;mso-border-bottom-alt:solid windowtext 1.5pt;  mso-padding-alt:0cm 3.5pt 0cm 3.5pt" width="550">     <tr>       <td width="112" valign="top" style="width:84.0pt;border-top:solid windowtext 1.5pt;   border-left:none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="line-height: 100%; tab-stops: 78.0pt; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>Material</b></font></td>       <td width="27" valign="top" style="width:20.45pt;border-top:solid windowtext 1.5pt;   border-left:none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-left-alt:solid windowtext .25pt;padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2"><b>n</b></font></p>       </td>       <td width="157" valign="top" style="width:117.55pt;border-top:solid windowtext 1.5pt;   border-left:none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-left-alt:solid windowtext .25pt;padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2"><b>Desinfectante</b></font></p>       </td>       <td width="160" valign="top" style="width:120.0pt;border-top:solid windowtext 1.5pt;   border-left:none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-left-alt:solid windowtext .25pt;padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2"><b>Método</b></font></p>       </td>       <td width="216" valign="top" style="width:162.0pt;border-top:solid windowtext 1.5pt;   border-left:none;border-bottom:solid windowtext .25pt;border-right:none;   mso-border-left-alt:solid windowtext .25pt;padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2"><b>Lavado</b></font></p>       </td>     </tr>     <tr>       <td width="112" valign="top" style="width:84.0pt;border-top:none;border-left:   none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">Polisulfuro</font></p>       </td>       <td width="27" valign="top" style="width:20.45pt;border-top:none;border-left:   none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">10</font></p>       </td>       <td width="157" valign="top" style="width:117.55pt;border-top:none;border-left:   none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Glutaraldehído         a 2%</font></p>       </td>       <td width="160" valign="top" style="width:120.0pt;border-top:none;border-left:   none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Inmersión         por 10 min</font></p>       </td>       <td width="216" valign="top" style="width:162.0pt;border:none;border-bottom:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             ]]></body>
<body><![CDATA[<p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Agua         destilada por 10 s</font></p>       </td>     </tr>     <tr>       <td width="112" valign="top" style="width:84.0pt;border-top:none;border-left:   none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">Poliéter</font></p>       </td>       <td width="27" valign="top" style="width:20.45pt;border-top:none;border-left:   none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">10</font></p>       </td>       <td width="157" valign="top" style="width:117.55pt;border-top:none;border-left:   none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Hipoclorito         de sodio a 1%</font></p>       </td>       <td width="160" valign="top" style="width:120.0pt;border-top:none;border-left:   none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Inmersión         por 10 min</font></p>       </td>       <td width="216" valign="top" style="width:162.0pt;border:none;border-bottom:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Agua         destilada por 10 s</font></p>       </td>     </tr>     <tr>       <td width="112" valign="top" style="width:84.0pt;border-top:none;border-left:   none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">Silicona</font>         <font face="Verdana" size="2">por adición</font></td>       <td width="27" valign="top" style="width:20.45pt;border-top:none;border-left:   none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">10</font></p>       </td>       <td width="157" valign="top" style="width:117.55pt;border-top:none;border-left:   none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Glutaraldehído         a 2%</font></p>       </td>       <td width="160" valign="top" style="width:120.0pt;border-top:none;border-left:   none;border-bottom:solid windowtext .25pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Inmersión         por 10 min</font></p>       </td>       <td width="216" valign="top" style="width:162.0pt;border:none;border-bottom:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             ]]></body>
<body><![CDATA[<p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Agua         destilada por 10 s</font></p>       </td>     </tr>     <tr>       <td width="112" valign="top" style="width:84.0pt;border-top:none;border-left:   none;border-bottom:solid windowtext 1.5pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">Silicona</font>         <font face="Verdana" size="2">por condensación</font></td>       <td width="27" valign="top" style="width:20.45pt;border-top:none;border-left:   none;border-bottom:solid windowtext 1.5pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">10</font></p>       </td>       <td width="157" valign="top" style="width:117.55pt;border-top:none;border-left:   none;border-bottom:solid windowtext 1.5pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Glutaraldehído         a 2%</font></p>       </td>       <td width="160" valign="top" style="width:120.0pt;border-top:none;border-left:   none;border-bottom:solid windowtext 1.5pt;border-right:solid windowtext .25pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Inmersión         por 10 min</font></p>       </td>       <td width="216" valign="top" style="width:162.0pt;border:none;border-bottom:solid windowtext 1.5pt;   mso-border-top-alt:solid windowtext .25pt;mso-border-left-alt:solid windowtext .25pt;   padding:0cm 3.5pt 0cm 3.5pt">             <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="center"><font face="Verdana" size="2">Agua         destilada por 10 s</font></p>       </td>     </tr>   </table>   </center> </div>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">Las diez muestras restantes no fueron sometidas a ningún agente de desinfección. Después de la inmersión en una de las culturas microbianas, fueron transferidas directamente para medios asociados a agentes antimicrobianos específicos, siendo consideradas como controles positivos. Para Streptococcus mutans y&nbsp; Staphylococcus aureus, el agente antimicrobiano utilizado fue el cloranfenicol de 250 mg (Medley/Brasil) y para Candida albicans, la nistatina 100.000 UI (EMS/Brasil).</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">Siguiéndose a la etapa de desinfección y lavado, los especímenes de cada elastómero fueron colocados en nuevos tubos de ensayo con el medio BHI (Brain Heart Infusion) para Streptococcus mutans y Staphylococcus aureus o agar Sabouraud para Candida albicans. Los tubos fueron, incubados en estufa a 37oC, por un periodo de 24 h, para posterior análisis de la turbidez del medio, indicativa de la existencia de crecimiento microbiano.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">Finalmente, para comprobar la eficacia del procedimiento de desinfección, se procedió a la siembra en agar de una alícuota de 0.1 ml de cada una de los cultivos microbianos conteniendo 108 UFC/ml, de acuerdo con el padrón 0.5 de la escala de McFarland. Las placas fueron incubadas en ambiente de microaerofilia durante 48 h, en estufa a 37oC.</font></p>     <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>RESULTADOS</b></font></p>     ]]></body>
<body><![CDATA[<p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">No hubo turbidez comprobatoria de crecimiento microbiano en ningún de los medios de cultivo que contenían especimenes sometidos a los agentes de desinfección testados. Por tanto, estos resultados confirman la eficacia antimicrobiana del glutaraldehído al 2% cuando utilizado para desinfección de impresiones de polisulfuro, siliconas por condensación o por adición y del hipoclorito de sodio a 1% cuando utilizado para desinfección de impresiones de poliéter, después de su inmersión durante 10 min.</font></p>     <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">No hubo crecimiento microbiano en ninguna de las muestras utilizadas como control positivo y todas las muestras utilizadas como control negativo presentaron contaminación, comprobada por la turbidez de los medios de cultivo.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>DISCUSIÓN</b></font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">Durante el proceso de toma de impresión, los materiales son contaminados con saliva, placa y, eventualmente sangre proveniente de la encía. Estos medios, por contener microorganismos, representan un riesgo de contaminación cruzada entre pacientes y profesionales de Odontología. Siendo así, es necesaria la adopción de un método de desinfección eficaz, con el objetivo de prevenir la infección cruzada.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">La opción por los microorganismos evaluados en este estudio se debió a diversos motivos. La Candida albicans es un&nbsp; microorganismo que se encuentra en la cavidad bucal de cerca de 60-70% de las personas. Ya el Streptococcus mutans es reconocido como siendo una de las especies bacterianas más relacionadas con el desarrollo de la caries, que es la enfermedad bucal más prevalente. Por fin, el Staphylococcus aureus es una bacteria relacionada con procesos infecciosos, de modo general.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">El simple lavado del material en agua destilada no se mostró eficaz en la eliminación de microorganismos, lo que ha sido constatado en los grupos utilizados como control negativo. Hubo turbidez en todos los medios de cultura que contenían muestras que no han sido sometidas a los agentes de desinfección, lo que comprueba que, después que hayan sido llevados a la boca, los materiales de impresión constituyen un riesgo de contaminación microbiana. Estos hallazgos están en acuerdo con los resultados obtenidos por Connor (4), que demostró que la etapa de lavado de la impresión en agua corriente no fue suficiente para eliminar microorganismos. Por otro lado, en los grupos utilizados para control positivo no hubo crecimiento microbiano, así como en los grupos-placebo. Estos hallazgos refuerzan la idea de que los métodos de desinfección deban ser rutinariamente adoptados en la práctica evitando, así, la infección cruzada y preservando la salud del paciente, del odontólogo y todo su equipo.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">Además del riesgo de contaminación con los microorganismos investigados, otros estudios llaman la atención para el riesgo de transmisión viral con los materiales elastoméricos (2,11). Trabajos como los de Donald y Robert (12) indican que los materiales de impresión tienen potencial para retener y transmitir virus, y la desinfección de ellos debe ser siempre realizada.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">La posibilidad de ocurrencia de alguna alteración dimensional debida a la desinfección de superficie de materiales de impresión con agentes químicos ha sido bastante discutida en la literatura. Estudios previos (7,13) han demostrado que impresiones de poliéter pueden ser adversamente afectadas por la inmersión en desinfectantes. En estos estudios, el tiempo de inmersión utilizado fue igual o superior a 30 min. Por esta razón, el Consejo de Materiales Dentarios, Instrumentos e Equipamientos de la ADA sugiere que el método de desinfección por vaporización debe ser preferido para poliéteres, al contrario del método de la inmersión (14). Sin embargo, de acuerdo con Merchant (15), la desinfección por inmersión es preferible, porque los desinfectantes vaporizados o en aerosol no promueven una desinfección homogénea, una vez que la superficie del molde puede no ser adecuadamente cubierta por la vaporización y, consecuentemente, no será totalmente desinfectada.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">Otros trabajos han demostrado que, cuando las impresiones&nbsp; de poliéter son sumergidas en agentes de desinfección por períodos menores que 30 min, estos no presentan alteraciones dimensiónales (6,9), lo que está de acuerdo con Anusavice (16), que relata que los materiales de impresión elastoméricos pueden ser sumergidas en soluciones desinfectantes sin producir alteraciones dimensiónales, siempre y cuando el tiempo de desinfección sea corto. Los estudios citados antes preconizan un tiempo de inmersión de 10 min, lo que está de acuerdo con el protocolo evaluado en el presente estudio.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">Considerando las siliconas por adición y a los polisulfuros estudios han comprobado que la estabilidad dimensional de estos materiales no es afectada por los métodos de desinfección por inmersión (6,7,8). Para las siliconas por condensación, las alteraciones dimensiónales encontradas han sido atribuidas mucho más a la instabilidad del material, que sufre una contracción en función de la evaporación de subproductos, que a los métodos de desinfección empleados (7).</font></p>     ]]></body>
<body><![CDATA[<p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">El protocolo de desinfección recomendado por la ADA (14) determina, además del tipo de agente antimicrobiano, cual es el tiempo de desinfección, la dilución y la temperatura necesarias para que cada agente tenga su mejor desempeño. Este estudio evaluó apenas la eficacia de agentes antimicrobianos en la desinfección de materiales de impresión para microorganismos específicos, sin embargo, vale la pena resaltar que las variables descritas anteriormente también deben ser consideradas para definirse un protocolo clínico que torne viable la desinfección y, al mismo tiempo, preserve la estabilidad dimensional de los materiales de impresión.</font></p>     <p style="line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2">Es preciso concienciar la clase odontológica de los riesgos de la infección cruzada proveniente de la manipulación de impresiones&nbsp; y modelos de yeso por parte del odontólogo y de su equipo, incluyendo técnicos de laboratorio en&nbsp; prótesis. Dentro de este contexto, los procedimientos de desinfección de impresiones aparecen como medidas de carácter indispensable para la protección de toda la clase profesional.</font></p>     <p style="text-indent: 0cm; line-height: 100%; tab-stops: 0cm; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>CONCLUSIONES</b></font></p>     <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">1. El glutaraldehído al 2% demostró ser eficaz en la desinfección de un material de impresión a base de polisulfuro, de una silicona por adición y de una silicona por condensación, cuando estos fueron contaminados con Staphylococcus aureus, Streptococcus mutans o Candida albicans.</font></p>     <p style="tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">2. El hipoclorito de sodio a 1% demostró ser eficaz en la desinfección de una impresión de poliéter cuando esta fue contaminada con Staphylococcus aureus, Streptococcus mutans o Candida albicans.</font></p>     <p style="text-indent: 0cm; tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">3. El protocolo de desinfección propuesto por la Comisión Permanente de Bio-seguridad de la FOUFMG para materiales de impresión elastoméricos se mostró eficaz para los materiales evaluados.</font></p>     <p style="text-indent: 0cm; tab-stops: 0cm; line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2"><b>REFERÉNCIAS BIBLIOGRÁFICAS</b></font></p>     <!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">1. Cserna , A.; Crist, R.L., Adams, A. B., Dunning, D.G.: Irreversible hydrocolloids: A comparison of antimicrobial efficacy. J. Prosthet. Dent. (1994); 71(4): 387-89.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122561&pid=S0001-6365200700010000500001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">2. Samaranayake, L.P.; Hunjan, M.; Jennings, K. J.: Carriage of oral flora on irreversible hydrocolloid and elastomeric impression materials.J. Prosthet. Dent. (1991);&nbsp; 65 (2): 244-49.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122562&pid=S0001-6365200700010000500002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">3. Watkinson, A. C.: Disinfection of impressions in UK Dental Schools. Br. Dent. J. (1988);&nbsp; 9: 22-23.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122563&pid=S0001-6365200700010000500003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">4. Connor, C. Cross-contamination control in prosthodontic practice. Int. J. Prosthodont. (1991); 4 (4): 337-344.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122564&pid=S0001-6365200700010000500004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">5. Rowe, A. H. R.; Forrest, J. O.: Dental Impressions: The probability of contamination and a method of disinfection.&nbsp; Br. Dent. J. (1978); 19: 184-86.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122565&pid=S0001-6365200700010000500005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">6. Langenwalter, E. M.; Aquilino, S. A., Turner, K. A.: The dimensional stability of elastomeric impression materials following disinfection J. Prosthet. Dent. (1990); 63 (3): 270-76.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122566&pid=S0001-6365200700010000500006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">7. Thouati, A.; Deveaux, E.; |Iost, A.; Behin, P.: Dimensional stability of seven elastomeric impression materials immersed in disinfectants. J. Prosthet. Dent. (1996); 76 (1): 8-14.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122567&pid=S0001-6365200700010000500007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">8. Johnson, G. H.; Chellis, K. D.; Gordon, G. E.; Lepe, X. Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion. J. Prosthet. Dent. (1998); 79 (4): 446-53.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122568&pid=S0001-6365200700010000500008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">9. Adabo, G. L.; Zanarotti, E.; Fonseca, R. G.; Cruz, C. A. S.: Effect of disinfectant agents on dimensional stability of elastomeric impression materials. J. Prosthet. Dent. (1999); 81 (5): 621-24.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122569&pid=S0001-6365200700010000500009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; tab-stops: 35.4pt; word-spacing: 0" align="justify"><font face="Verdana" size="2">10. Comissão Permanente de Biossegurança da Faculdade de Odontologia-UFMG: Controle de infecção em Odontologia: manual de normas e rotinas técnicas. Belo Horizonte, 2003.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122570&pid=S0001-6365200700010000500010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">11.Minagi, S.; Fukushima, K.; Maeda, N.; Satomi, K.; Ohkawa, S.; Akagawa, Y.; Miyake, Y.; Suginaka, H.; Tsuru, H.: Disinfection method for impression materials: freedom from fear of hepatitis b and acquired immunodeficiency syndrome. J. Prosthet. Dent. (1986); .56 (4): 451-54.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122571&pid=S0001-6365200700010000500011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">12. Donald, E. G.; Robert, J. S.: Impression materials and virus. J. Am. Dent. Assoc. (1991); 122: 51-54.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122572&pid=S0001-6365200700010000500012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">13. Setcos, J. C.; Gerstenblatt, R.; Palenik, C. J.; Hinoura, K.: Disinfection of a polyether dental impression material (abstract). J. Dent. Res. (1985); 62: 244.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122573&pid=S0001-6365200700010000500013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">14. Council on Scientific Affairs and Council on Dental Practice. Infection control recommendations for the dental office and the dental laboratory. J. Am. Dent. Assoc. (1996); 127: 672-80.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122574&pid=S0001-6365200700010000500014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">15. Merchant, V. A.; Radcliffe, R. M.; Herrera, s. P.; Stroster, T. G.: Dimensional stability of reversible hydrocolloid impressions immersed in selected disinfectant solutions. J. Am. Dent.Assoc. (1989); 119: 49-53.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122575&pid=S0001-6365200700010000500015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%; word-spacing: 0" align="justify"><font face="Verdana" size="2">16. Anusavice, K.,J.: Phillips, materiais dentários. 11a Ed. Rio de Janeiro, Elsevier (2005).</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=122576&pid=S0001-6365200700010000500016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body>
<back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cserna]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Crist]]></surname>
<given-names><![CDATA[R.L.]]></given-names>
</name>
<name>
<surname><![CDATA[Adams]]></surname>
<given-names><![CDATA[A. B]]></given-names>
</name>
<name>
<surname><![CDATA[Dunning]]></surname>
<given-names><![CDATA[D.G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Irreversible hydrocolloids: A comparison of antimicrobial efficacy.]]></article-title>
<source><![CDATA[J. Prosthet. Dent.]]></source>
<year>1994</year>
<volume>71</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>387-89</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Samaranayake]]></surname>
<given-names><![CDATA[L.P.]]></given-names>
</name>
<name>
<surname><![CDATA[Hunjan]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Jennings]]></surname>
<given-names><![CDATA[K. J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Carriage of oral flora on irreversible hydrocolloid and elastomeric impression materials.]]></article-title>
<source><![CDATA[J. Prosthet. Dent.]]></source>
<year>1991</year>
<volume>65</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>244-49</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Watkinson]]></surname>
<given-names><![CDATA[A. C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Disinfection of impressions in UK Dental Schools.]]></article-title>
<source><![CDATA[Br. Dent. J.]]></source>
<year>1988</year>
<volume>9</volume>
<page-range>22-23</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Connor]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cross-contamination control in prosthodontic practice.]]></article-title>
<source><![CDATA[Int. J. Prosthodont.]]></source>
<year>1991</year>
<volume>4</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>337-344</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rowe]]></surname>
<given-names><![CDATA[A. H. R]]></given-names>
</name>
<name>
<surname><![CDATA[Forrest]]></surname>
<given-names><![CDATA[J. O]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Dental Impressions: The probability of contamination and a method of disinfection.]]></article-title>
<source><![CDATA[Br. Dent. J.]]></source>
<year>1978</year>
<volume>19</volume>
<page-range>184-86</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Langenwalter]]></surname>
<given-names><![CDATA[E. M]]></given-names>
</name>
<name>
<surname><![CDATA[Aquilino]]></surname>
<given-names><![CDATA[S. A]]></given-names>
</name>
<name>
<surname><![CDATA[Turner]]></surname>
<given-names><![CDATA[K. A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The dimensional stability of elastomeric impression materials following disinfection]]></article-title>
<source><![CDATA[J. Prosthet. Dent.]]></source>
<year>1990</year>
<volume>63</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>270-76</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thouati]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Deveaux]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Iost]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Behin]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Dimensional stability of seven elastomeric impression materials immersed in disinfectants.]]></article-title>
<source><![CDATA[J. Prosthet. Dent.]]></source>
<year>1996</year>
<volume>76</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>8-14.</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Johnson]]></surname>
<given-names><![CDATA[G. H]]></given-names>
</name>
<name>
<surname><![CDATA[Chellis]]></surname>
<given-names><![CDATA[K. D]]></given-names>
</name>
<name>
<surname><![CDATA[Gordon]]></surname>
<given-names><![CDATA[G. E]]></given-names>
</name>
<name>
<surname><![CDATA[Lepe]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion.]]></article-title>
<source><![CDATA[J. Prosthet. Dent.]]></source>
<year>1998</year>
<volume>79</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>446-53</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Adabo]]></surname>
<given-names><![CDATA[G. L]]></given-names>
</name>
<name>
<surname><![CDATA[Zanarotti]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Fonseca]]></surname>
<given-names><![CDATA[R. G]]></given-names>
</name>
<name>
<surname><![CDATA[Cruz]]></surname>
<given-names><![CDATA[C. A. S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of disinfectant agents on dimensional stability of elastomeric impression materials.]]></article-title>
<source><![CDATA[J. Prosthet. Dent.]]></source>
<year>1999</year>
<volume>81</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>621-24</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="">
<collab>Comissão Permanente de Biossegurança da Faculdade de Odontologia-UFMG</collab>
<source><![CDATA[Controle de infecção em Odontologia: manual de normas e rotinas técnicas.]]></source>
<year>2003</year>
<publisher-loc><![CDATA[Belo Horizonte ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Minagi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Fukushima]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Maeda]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Satomi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Ohkawa]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Akagawa]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Miyake]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Suginaka]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Tsuru]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Disinfection method for impression materials: freedom from fear of hepatitis b and acquired immunodeficiency syndrome]]></article-title>
<source><![CDATA[J. Prosthet. Dent.]]></source>
<year>1986</year>
<volume>56</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>451-54</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Donald]]></surname>
<given-names><![CDATA[E. G]]></given-names>
</name>
<name>
<surname><![CDATA[Robert]]></surname>
<given-names><![CDATA[J. S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Impression materials and virus]]></article-title>
<source><![CDATA[J. Am. Dent. Assoc.]]></source>
<year>1991</year>
<volume>122</volume>
<page-range>51-54</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Setcos]]></surname>
<given-names><![CDATA[J. C]]></given-names>
</name>
<name>
<surname><![CDATA[Gerstenblatt]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Palenik]]></surname>
<given-names><![CDATA[C. J]]></given-names>
</name>
<name>
<surname><![CDATA[Hinoura]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Disinfection of a polyether dental impression material]]></article-title>
<source><![CDATA[J. Dent. Res.]]></source>
<year>1985</year>
<volume>62</volume>
<page-range>244</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<collab>Council on Scientific Affairs and Council on Dental Practice.</collab>
<article-title xml:lang="en"><![CDATA[Infection control recommendations for the dental office and the dental laboratory]]></article-title>
<source><![CDATA[J. Am. Dent. Assoc.]]></source>
<year>1996</year>
<volume>127</volume>
<page-range>672-80</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Merchant]]></surname>
<given-names><![CDATA[V. A]]></given-names>
</name>
<name>
<surname><![CDATA[Radcliffe]]></surname>
<given-names><![CDATA[R. M]]></given-names>
</name>
<name>
<surname><![CDATA[Herrera]]></surname>
<given-names><![CDATA[s. P]]></given-names>
</name>
<name>
<surname><![CDATA[Stroster]]></surname>
<given-names><![CDATA[T. G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Dimensional stability of reversible hydrocolloid impressions immersed in selected disinfectant solutions]]></article-title>
<source><![CDATA[J. Am. Dent.Assoc]]></source>
<year>1989</year>
<volume>119</volume>
<page-range>49-53</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Anusavice]]></surname>
<given-names><![CDATA[K.,J]]></given-names>
</name>
</person-group>
<source><![CDATA[Phillips, materiais dentários]]></source>
<year>2005</year>
<edition>11a Ed</edition>
<publisher-loc><![CDATA[Rio de Janeiro ]]></publisher-loc>
<publisher-name><![CDATA[Elsevier]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
