<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0367-4762</journal-id>
<journal-title><![CDATA[Gaceta Médica de Caracas]]></journal-title>
<abbrev-journal-title><![CDATA[Gac Méd Caracas.]]></abbrev-journal-title>
<issn>0367-4762</issn>
<publisher>
<publisher-name><![CDATA[ATEPROCA]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0367-47622007000100005</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Indicaciones actuales del implante de filtros recuperables en la vena cava inferior]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Vargas]]></surname>
<given-names><![CDATA[Braulio]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Muñoz R]]></surname>
<given-names><![CDATA[Juan Simón]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Francisco Tortoledo]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Izaguirre B]]></surname>
<given-names><![CDATA[Leonardo]]></given-names>
</name>
</contrib>
</contrib-group>
<aff id="A">
<institution><![CDATA[,  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>01</month>
<year>2007</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>01</month>
<year>2007</year>
</pub-date>
<volume>115</volume>
<numero>1</numero>
<fpage>48</fpage>
<lpage>54</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_arttext&amp;pid=S0367-47622007000100005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_abstract&amp;pid=S0367-47622007000100005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_pdf&amp;pid=S0367-47622007000100005&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[El tromboembolismo venoso es una patología que ocurre aproximadamente en 1 de cada 1 000 personas en el mundo, de las cuales más de la mitad corresponde a casos de trombosis venosa profunda. La principal complicación aguda de la trombosis venosa profunda es el embolismo pulmonar, que resulta fatal en 20 %-30 % de los casos. La anticoagulación es la estrategia más eficaz para la prevención de esta complicación, sin embargo, está contraindicada en situaciones frecuentes. Los filtros de vena cava inferior constituyen una alternativa no farmacológica para la prevención del embolismo pulmonar en aquellos pacientes que presentan trombosis venosa profunda. Este artículo hace revisión de los aspectos históricos de estos dispositivos, con especial interés en los denominados filtros recuperables, en cuanto a sus indicaciones, técnica de colocación-retiro, eficacia y seguridad.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Venous thromboembolism is a disease which occurs in 1 out of 1 000 people around the world, accounting for about a half of cases of deep venous thrombosis. Deep venous thrombosis major complication is pulmonary embolism, fatal in 20 %-30 % of cases. Anticoagulation is the most effective strategy to prevent pulmonary embolism, however, this is contraindicated in frequent clinical situations. Inferior vena cava filters are a non-pharmacological alternative in these cases. This article reviews historical aspects of these devices, with particular interest in those denominated retrievable filters, describing indications, implantation-retrieval technique, efficacy and safety.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Filtro de vena cava]]></kwd>
<kwd lng="es"><![CDATA[Filtro recuperable]]></kwd>
<kwd lng="es"><![CDATA[Tromboembolismo venoso]]></kwd>
<kwd lng="es"><![CDATA[Trombosis venosa profunda]]></kwd>
<kwd lng="es"><![CDATA[Embolismo pulmonar]]></kwd>
<kwd lng="en"><![CDATA[Vena cava filter]]></kwd>
<kwd lng="en"><![CDATA[Retrievable filter]]></kwd>
<kwd lng="en"><![CDATA[Venous thromboembolism]]></kwd>
<kwd lng="en"><![CDATA[Deep venous trombosis]]></kwd>
<kwd lng="en"><![CDATA[Pulmonary embolism]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[   <h2 align="center" style="text-align:center"><span style="color: #231D1D"> <font size="4">Indicaciones actuales del implante de filtros recuperables en la  vena cava inferior</font></span></h2>     <p style="text-align:justify"><span style="color:#231D1D">Drs. Braulio Vargas,  Juan Simón Muñoz R, Francisco Tortoledo R, Leonardo Izaguirre B Laboratorio de  Exploraciones e Intervenciones Cardiovasculares. Instituto Médico La Floresta.  Caracas, Venezuela </span></p>     <p style="text-align:justify"><span style="color:#231D1D">Correspondencia: Dr.  Braulio Vargas. doctorvargas@gmail.com </span></p>     <p style="text-align:justify"><span style="color:#231D1D">&nbsp;</span></p> <h5 style="text-align:justify"><span style="font-size:12.0pt;color:#231D1D"> RESUMEN </span></h5>     <p style="text-align:justify"><span style="color: #231D1D">El tromboembolismo  venoso es una patología que ocurre aproximadamente en 1 de cada 1 000 personas  en el mundo, de las cuales más de la mitad corresponde a casos de trombosis  venosa profunda. La principal complicación aguda de la trombosis venosa profunda  es el embolismo pulmonar, que resulta fatal en 20 %-30 % de los casos. La  anticoagulación es la estrategia más eficaz para la prevención de esta  complicación, sin embargo, está contraindicada en situaciones frecuentes. Los  filtros de vena cava inferior constituyen una alternativa no farmacológica para  la prevención del embolismo pulmonar en aquellos pacientes que presentan  trombosis venosa profunda. Este artículo hace revisión de los aspectos  históricos de estos dispositivos, con especial interés en los denominados  filtros recuperables, en cuanto a sus indicaciones, técnica de  colocación-retiro, eficacia y seguridad<i>. </i></span></p>     <p style="text-align:justify"><b><span style="color: #231D1D">Palabras clave</span></b><span style="color: #231D1D">:  Filtro de vena cava. Filtro recuperable. Tromboembolismo venoso. Trombosis  venosa profunda. </span><span lang="EN-US" style="color: #231D1D">Embolismo  pulmonar. </span></p> <h5 style="text-align:justify"> <span lang="EN-US" style="font-size: 12.0pt; color: #231D1D">SUMMARY </span> </h5>     <p style="text-align:justify"><span lang="EN-US" style="color: #231D1D">Venous  thromboembolism is a disease which occurs in 1 out of 1 000 people around the  world, accounting for about a half of cases of deep venous thrombosis. Deep  venous thrombosis major complication is pulmonary embolism, fatal in 20 %-30 %  of cases. Anticoagulation is the most effective strategy to prevent pulmonary  embolism, however, this is contraindicated in frequent clinical situations.  Inferior vena cava filters are a non-pharmacological alternative in these cases.  This article reviews historical aspects of these devices, with particular  interest in those denominated retrievable filters, describing indications,  implantation-retrieval technique, efficacy and safety. </span></p>     <p style="text-align:justify"><b><span lang="EN-US" style="color: #231D1D">Key  words</span></b><span lang="EN-US" style="color: #231D1D">: Vena cava filter.  Retrievable filter. Venous thromboembolism. Deep venous trombosis. Pulmonary  embolism. </span></p> <h5 style="text-align:justify"><span style="font-size:12.0pt;color:#231D1D"> INTRODUCCIÓN </span></h5>     <p style="text-align:justify"><span style="color:#231D1D">El tromboembolismo  venoso (TEV) es una patología que ocurre aproximadamente en 1 de cada 1 000  personas en el mundo (1), de las cuales más de la mitad corresponde a casos de  trombosis venosa profunda (TVP) (2). Los factores de riesgo (<a href="#cuadr1">Cuadro  1</a>) que condicionan la aparición de esta entidad nosológica quedan definidos  por la clásica triada de Virchow, que establece la participación de una pared  venosa dañada, el estásis sanguíneo venoso y un estado procoagulante anómalo  como pilares fundamentales de su patogénesis. </span></p>     <p style="text-align:justify"><span style="color:#231D1D">La principal  complicación aguda de la TVP es el embolismo pulmonar (EP), que resulta fatal en  20 %-30 % de los casos (3), causando aproximadamente 60 000 muertes anuales en  Estados Unidos (4). </span></p>     ]]></body>
<body><![CDATA[<p style="text-align:justify"><span style="color:#231D1D">Por tanto, resulta  imperativo implementar intervenciones profilácticas para el EP, siendo la  anticoagulación oral y/o parenteral la estrategia más eficaz para la prevención  de esta temida complicación. No obstante, algunas condiciones como el sangrado  activo, trombocitopenia severa, hemorragia intracraneal o neurocirugía reciente,  así como las complicaciones propias del uso de fármacos anticoagulantes, han  limitado su uso en ciertos pacientes y son motivo para la búsqueda de otras  alternativas de tratamiento. </span></p>     <p style="text-align:justify"><span style="color:#231D1D">Los filtros de vena  cava inferior (FVCI) constituyen una alternativa no farmacológica para la  prevención de EP en aquellos pacientes que presentan TVP. Su mecanismo de acción  es de barrera física, que impide la migración de trombos desde la circulación  venosa de los miembros inferiores hacia el corazón derecho y consecuentemente al  lecho vascular dependiente de la arteria pulmonar. </span></p>     <p style="text-align: center"><span style="color:#231D1D">&nbsp;<a name="cuadr1"><img border="0" src="/img/fbpe/gmc/art05cuadr1.jpg" width="578" height="281"></a></span></p>     
<p style="text-align:justify"><span style="color:#231D1D">&nbsp;Existen dos clases de  FVCI: permanentes y no permanentes. Son denominados no permanentes aquellos FVCI  que pueden ser removidos luego de su implantación y estos a su vez, en base a  sus características, han sido clasificados en 2 tipos: filtros temporales,  refiriéndose este término a dispositivos que permanecen unidos a una guía  metálica o catéter transcutáneo que facilita su posterior retiro, y filtros  recuperables, que son similares a los filtros permanentes y cuyo diseño permite  removerlos con un dispositivo de captura por vía endovascular. Esta última clase  de filtro tiene como ventaja que al no estar conectados a una guía o catéter, se  disminuye el riesgo de trombosis del sitio de punción y de infecciones.  Asimismo, un filtro recuperable ofrece la posibilidad de ser reposicionado con  la finalidad de prolongar indefinidamente su permanencia en la vena cava  inferior, existiendo registros de casos donde el tiempo de permanencia se ha  extendido exitosamente hasta un máximo de 317 días (5-8). </span></p> <h5 style="text-align:justify"><span style="font-size:12.0pt;color:#231D1D"> MATERIAL Y MÉTODOS </span></h5>     <p style="text-align:justify"><span style="color:#231D1D">Desde la introducción  de la ligadura de la vena femoral común por Hunter en 1874 (9) y la ligadura de  vena cava inferior por Ochsner y col. (10) en la década de los 40’s, muchos  diseños han sido propuestos hasta el desarrollo de los modernos FVCI no  permanentes. </span></p>     <p style="text-align:justify"><span style="color:#231D1D">El filtro permanente  Greenfield (Boston Scientific/Meditech), implantado inicialmente por abordaje  quirúrgico en 1973 (11) y posteriormente de forma percutánea a partir de 1984,  ha sido utilizado universalmente por largo tiempo, inspirando el diseño de otros  filtros como el Bird’s Nest (Cook, Estados Unidos;1982), VenaTech (VenaTech,  Estados Unidos; 1986), Simon Nitinol (Bard, Estados Unidos; 1988), Titanium  Greenfield y Stainless-Steel Over-the-Wire Greenfield (Boston Scientific/Meditech,  Estados Unidos; 1988 y 1994, respectivamente), TrapEase (Cordis, Holanda; 2000)  y el VenaTech Low-Profile (B. Braun, Francia; 2001) (12). </span></p>     <p style="text-align:justify"><span style="color:#231D1D">El primer reporte de  recuperación exitosa de un FVCI no permanente fue realizado por Darcy y col.  (13) en 1986, con un filtro Amplatz (William Cook Europe, Dinamarca),  encontrándose actualmente en el mercado los filtros recuperables OptEase (Cordis),  Recovery Nitinol (Bard) y el Günther-Tulip (Cook) (4), utilizado en nuestro  laboratorio de hemodinamia. El filtro Günther-Tulip (FGT, Cook, Estados Unidos; <a href="#fig1">Figura 1</a>) es un dispositivo no permanente recuperable  elaborado en aleación no magnética (cobalto, níquel y cromo principalmente).  Tiene forma de media cesta, con cuatro alambres que salen fuera de ella,  terminando cada uno de ellos en una curvatura diseñada para adaptarse a la pared  de la vena cava inferior. Asimismo, por su condición de recuperable, posee un  gancho en el ápex que permite la recuperación o reposicionamiento por vía  percutánea. Para su implantación, el FGT viene en un equipo que contiene: un  sistema coaxial introductor de 8,5 French, compuesto por un dilatador y una  camisa (<a href="#fig2">Figura 2-A</a>) y un dispositivo introductor con el  filtro precargado, que facilita su liberación en la vena cava inferior al  accionar un dispositivo de seguridad (<a href="#fig2">Figura 2-B</a>). </span> </p>     <p style="text-align:justify"><span style="color:#231D1D">El procedimiento para  implantar el FGT se realiza mediante acceso percutáneo a través de la vena  femoral común derecha, previa anestesia local con lidocaína al 2 % y utilizando  la técnica de Seldinger. A continuación, bajo control fluoroscópico, se  posiciona una guía metálica hasta la vena cava inferior y se realiza un  venograma para reconocer la anatomía de las venas iliacas y cava inferior,  considerando la posibilidad de variaciones anatómicas y visualizar las venas  renales, que son el punto de referencia clave por debajo del cual siempre debe  quedar implantado el filtro (<a href="#fig3">Figura 3-A</a>). Posteriormente se  introduce a través de la guía metálica, el sistema coaxial de 8,5 French hasta  por debajo de las venas renales, retirándose a continuación el dilatador y la  guía. Se introduce el filtro precargado través de la camisa y se retira ésta,  manteniendo el filtro precargado inmóvil, lo suficiente hasta que los alambres  del filtro quedan expuestos (<a href="#fig3">Figura 3-A</a>). La liberación del  filtro se realiza girando el sistema de seguridad en sentido horario y  retirándose en conjunto el introductor y la camisa (<a href="#fig3">Figura 3-B</a>),  de manera que los alambres se abren y se fijan a la pared de la vena cava  inferior (<a href="#fig3">Figura 3-C</a>). Finalmente se realiza un venograma  para confirmar que el FGT no se haya desplazado. </span></p>     <p style="text-align: center"><span style="color:#231D1D">&nbsp;<a name="fig1"><img border="0" src="/img/fbpe/gmc/art05_img_0.jpg" width="381" height="112"></a></span></p>     
<p style="text-align:justify"><span style="color:#231D1D">&nbsp;</span></p>     ]]></body>
<body><![CDATA[<p style="text-align:justify"><span style="color:#231D1D"><b>Figura 1</b>.  Filtro Günther-Tulip. A. Vista frontal. B. Vista superior. C. Detalle del  alambre y su punto de fijación a la pared venosa (flecha). D. Detalle del gancho  para recuperación. </span></p>     <p style="text-align: center"><span style="color:#231D1D">&nbsp;<a name="fig2"><img border="0" src="/img/fbpe/gmc/art05_img_1.jpg" width="341" height="128"></a></span></p>     
<p style="text-align:justify"><span style="color:#231D1D"><b>Figura 2.</b>  Componentes del sistema de implante del filtro Günther-Tulip. A. Sistema coaxial  introductor: A1. Camisa, A2. Dilatador. B. Introductor: B1. Sistema de  seguridad, B2. filtro precargado. </span></p>     <p style="text-align:justify"><span style="color:#231D1D">Para recuperar el FGT  se utiliza un sistema coaxial de recuperación de 11 French (<a href="#fig4">Figura  4-A</a>) y un dispositivo tipo asa elaborado en platino trenzado, producidos por  el fabricante del filtro (<a href="#fig4">Figuras 4-B y C</a>). El procedimiento  se realiza mediante acceso percutáneo de la vena yugular derecha de manera de  posicionar, a través de una guía metálica, el sistema coaxial recuperador en la  vena cava inferior, tomando como referencia la localización del filtro bajo  control fluoroscópico (<a href="#fig5">Figura 5-A</a>) y retirándose  posteriormente el dilatador y la guía metálica. A continuación se introduce el  sistema con el asa de recuperación a través de la camisa y se avanza hasta que  el asa rodee el filtro y se hala hasta que este logre capturar el gancho de  recuperación (<a href="#fig5">Figura 5B</a>). Lograda la captura del gancho, se  retrae el sistema, lo cual permite desprender el filtro de la pared venosa,  introducirlo y colapsarlo totalmente dentro de la camisa (<a href="#fig5">Figuras  5-C y D</a>), retirando en este momento fuera del paciente el ensamblaje  camisa-filtro. Finalmente es posible la observación macroscópica del filtro en  búsqueda de material atrapado (<a href="#fig5">Figura 5-E</a>). </span></p>     <p style="text-align: center"><span style="color:#231D1D">&nbsp;<a name="fig3"><img border="0" src="/img/fbpe/gmc/art05_img_2.jpg" width="336" height="131"></a></span></p>     
<p style="text-align:justify"><span style="color:#231D1D"><b>Figura 3</b>.  Implante del filtro Günther-Tulip. A. Venograma: VCI, Vena cava inferior. VRI,  Vena renal izquierda. B. Retiro de la camisa y exposición del filtro. C. Filtro  desplegado luego de su liberación. </span></p>     <p style="text-align: center"><span style="color:#231D1D">&nbsp;</span><span style="color: #231D1D"><a name="fig4"><img border="0" src="/img/fbpe/gmc/art05_img_3.jpg" width="335" height="84"></a></span></p>     
<p style="text-align:justify"><span style="color:#231D1D"><b>Figura 4.</b>  Sistema de recuperación del filtro Günther-Tulip. A. Sistema coaxial de  recuperación: A1. Camisa, A2. Dilatador. B. Sistema con asa de recuperación  (flecha). C. Detalle del asa de recuperación. </span></p>     <p class="MsoNormal" style="text-align: center"><span style="color:#231D1D">&nbsp;<a name="fig5"><img border="0" src="/img/fbpe/gmc/art05_img_4.jpg" width="187" height="315"></a></span></p>     
<p style="text-align:justify"><span style="color:#231D1D"><b>Figura 5.</b>  Recuperando un filtro Günther-Tulip. A. Visualización del filtro. B. Asa de  platino capturando el gancho de recuperación (flecha). C y D. El filtro se  recupera a través de la camisa. E. Detalle del filtro recuperado con material  atrapado. </span></p> <h5 style="text-align:justify"><span style="font-size:12.0pt;color:#231D1D"> DISCUSIÓN </span></h5>     ]]></body>
<body><![CDATA[<p style="text-align:justify"><span style="color:#231D1D">En este artículo se  ofrece una breve revisión de los aspectos más importantes de la actualidad de  los FVCI, con la convicción sobre su eficacia y seguridad en el tratamiento  preventivo del EP. En este sentido, hemos elegido al FGT como dispositivo en  nuestras intervenciones ya que consideramos reúne características que lo acercan  al filtro ideal de la teoría. De interés particular resulta su diseño  recuperable, que permite no sólo su retiro a través de un sencillo abordaje  yugular percutáneo, sino su reposicionamiento si la intención es que actúe como  filtro permanente mientras esté indicado. </span></p>     <p style="text-align:justify"><span style="color:#231D1D">Las indicaciones para  la colocación de un FVCI están asociadas a aquellas circunstancias donde se  requiera prevenir la ocurrencia de EP y el uso de anticoagulantes no es posible  o han ocasionado algunas complicaciones. Las mismas fueron descritas por el  panel del Vena Caval Consensus Conference 2003 (4) y se enumeran en el <a href="#cuadr2">Cuadro 2.</a> Las únicas contraindicaciones absolutas para la  implantación de estos filtros son la trombosis total de la vena cava inferior y  la imposibilidad de obtener acceso a esta. No se recomienda su uso en la edad  adolescente, ya que sería necesario dejarlos por grandes períodos de tiempo y no  se dispone de datos que apoyen la efectividad de estos a largo plazo (12). </span></p>     <p style="text-align: center"><span style="color:#231D1D">&nbsp;<a name="cuadr2"><img border="0" src="/img/fbpe/gmc/art05cuadr2.jpg" width="578" height="639"></a></span></p>     
<p style="text-align: center"><span style="color:#231D1D">&nbsp;</span></p>     <p style="text-align:justify"><span style="color:#231D1D">En cuanto a las  complicaciones, la muerte asociada al uso de FVCI es rara, con una incidencia  registrada del 0,12 %. Las complicaciones más importantes son la migración del  filtro, el EP recurrente y la trombosis. La migración del filtro posterior a su  liberación en la vena cava inferior ocurre aproximadamente en el 2 %-3 % de los  casos, encontrándose series con incidencias mayores que deben ser interpretadas  con juicio crítico considerando ciertos sesgos metodológicos. El EP recurrente  posterior al implante de FVCI ocurre en aproximadamente 2 %-5 % de los casos. Es  importante tener en cuenta que este bajo porcentaje de casos puede estar  determinado por un subregistro considerable debido a EP no diagnosticados por  ausencia de manifestaciones clínicas y la variabilidad en el tiempo de  seguimiento de los protocolos. La incidencia de trombosis del filtro es de 6  %-30 % y en el caso de la trombosis del sitio de acceso, la incidencia oscila  entre 2 %-28 %. La variabilidad de estas incidencias está relacionada con las  características de los estudios y los tipos de filtros utilizados, en lo cual es  importante considerar las características del sistema introductor-liberador de  estos (12). </span></p>     <p style="text-align:justify"><span style="color:#231D1D">Un FVCI “ideal” debe  tener como principales atributos: no ser trombogénico, capacidad de atrapar  émbolos —grandes y pequeños— sin interrumpir el flujo venoso, funcionalidad por  tiempo indefinido, facilidad para la implantación, reposicionamiento y retiro;  no causar daño a la pared venosa, compatibilidad con estudios de resonancia  magnética nuclear, bajo costo y poca asociación con morbilidad y mortalidad  (12). </span></p>     <p style="text-align:justify"><span style="color:#231D1D">La eficacia de los  FVCI ha sido sugerida positivamente a través de múltiples publicaciones  (5-8,12-21). No obstante, estos reportes no representan evidencia definitiva  porque no son protocolos prospectivos, aleatorizados, comparativos y con  muestras significativas, conteniendo sesgos metodológicos en cuanto a selección  de muestras, criterios de evaluación a corto y largo plazo y la manera en que se  realiza este seguimiento. En este sentido, la Sociedad de Radiología  Intervencionista de Estados Unidos (SIR, por sus siglas en inglés) ha propuesto  directrices para la elaboración de protocolos para reportar la colocación de  diferentes FVCI y el seguimiento de los casos (22,23). </span></p>     <p style="text-align:justify"><span style="color:#231D1D">La experiencia inicial  del Laboratorio de Exploraciones e Intervenciones Cardiovasculares (LEIC) del  Instituto Médico La Floresta consiste en la colocación de 3 FVCI en 3 pacientes  (2 hombres, 1 mujer), todos durante el año 2005, mediante la técnica antes  descrita y sin registro de complicaciones inherentes al procedimiento o al  dispositivo. La recuperación del filtro sólo se ha realizado en uno de estos  pacientes, a los 40 días de implantación, sin complicaciones. El filtro se puede  observar en la<a href="#fig5"> Figura 5-E</a> cuyo contenido es material  trombótico. Un paciente falleció por causas no relacionadas al filtro ni EP y  uno continúa en seguimiento clínico. </span></p>     <p style="text-align:justify"><span style="color:#231D1D">Esta experiencia  inicial ciertamente es positiva en cuanto a que hemos podido colocar de manera  segura estos filtros y hemos observado el beneficio para cada sujeto en  particular, pero son necesarios más pacientes bajo un protocolo de peso  siguiendo directrices ya disponibles para llegar a conclusiones generales. </span></p>     <p style="text-align:justify"><span style="color:#231D1D">Basado en lo anterior,  concluimos que el uso de FVCI recuperables —en particular el FGT— es factible y  seguro. La eficacia de estos dispositivos ha sido comprobada en los pacientes  que han sido sometidos al procedimiento en nuestra institución y es comparable a  lo reportado en las series de casos disponibles. Resulta imperativo diseñar  protocolos clínicos con características idóneas para considerar sus resultados  como evidencia definitiva sobre los beneficios de esta tecnología emergente para  nuestros pacientes. </span></p>     ]]></body>
<body><![CDATA[<p style="text-align:justify"><b><span style="color:#231D1D">REFERENCIAS </span> </b></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="EN-US" style="color: #231D1D">Tovey C, Wyatt S. Diagnosis,  investigation, and management of deep vein thrombosis. </span> <span style="color:#231D1D">BMJ. 2003;326:11801184. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="EN-US" style="color: #231D1D">Bates SM, Ginsberg JS. Treatment of  deep-vein thrombosis. </span><span style="color:#231D1D">N Engl J Med.  2004;351:268-277. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="EN-US" style="color: #231D1D">Fedullo PF, Tapson VF. The evaluation  of suspected pulmonary embolism. </span><span style="color:#231D1D">N Engl J Med.  2003;349:12471256. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="DE" style="color: #231D1D">Lin PH, Bush RL, Lumsden AB. </span> <span lang="EN-US" style="color: #231D1D">Vena caval filters in the treatment of  acute DVT. </span><span style="color:#231D1D">Endovasc Today. 2005;4(1):40-50. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="EN-US" style="color: #231D1D">Binkert CA, Bansal A, Gates JD.  Inferior vena cava filter removal after 317-day implantation. </span> <span style="color:#231D1D">J Vasc Interv Radiol. 2005;16(3):395-398. </span> </p>     ]]></body>
<body><![CDATA[<p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span style="color:#231D1D">Haider EA, Rosen JC, Torres C, Valenti DA. Serial  repositioning of a Gunther Tulip retrievable inferior vena cava filter in a  pediatric patient. Pediatr Radiol. 2005;35(11):1135-1138. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="EN-US" style="color: #231D1D">Terhaar OA, Lyon SM, Given MF, Foster  AE, Mc Grath F, Lee MJ. Extended interval for retrieval of Gunther Tulip  filters. </span><span style="color:#231D1D">J Vasc Interv Radiol.  2004;15(11):12571262. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span style="color:#231D1D">de Gregorio MA, Gamboa P, Gimeno MJ, Madariaga B,  Tobio R, Herrera M, et al. </span><span lang="EN-US" style="color: #231D1D">The  Gunther Tulip retrievable filter: Prolonged temporary filtration by  repositioning within the inferior vena cava. </span><span style="color:#231D1D"> J Vasc Interv Radiol. 2003;14(10):1259-1265. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="EN-US" style="color: #231D1D">Greenfield LJ. Evolution of venous  interruption for pulmonary thromboembolism. </span><span style="color:#231D1D"> Arch Surg. 1992; 127:622-626. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="EN-US" style="color: #231D1D">Ochsner A, Ochsner JL, Saunders HS.  Prevention of pulmonary embolism by caval ligation. </span> <span style="color:#231D1D">Ann Surg. 1970;171:923-938. </span></p>     ]]></body>
<body><![CDATA[<p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="EN-US" style="color: #231D1D">Greenfield LJ, McCrudy JR, Brown PP,  Elkins RC. A new intracaval filter permitting continued flow and resolution of  emboli. </span><span style="color:#231D1D">Surgery. 1973;73:599-606. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="EN-US" style="color: #231D1D">Kinney TB. Update on inferior vena  cava filters. </span><span style="color:#231D1D">J Vasc Interv Radiol.  2003;14:425-440. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span style="color:#231D1D">Darcy MD, Smith TP, Hunter DW, Castaneda-Zuniga W,  Lung G, Amplatz K. Short-term prophylaxis of pulmonary embolism by using a  retrievable vena cava filter. Am J Roentgenol. 1986;147:836-838. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="EN-US" style="color: #231D1D">Yamagami T, Kato T, Lida S, Hirota T,  Nishimura T. Gunther Tulip inferior vena cava filter placement during treatment  for deep venous thrombosis of the lower extremity. </span> <span style="color:#231D1D">Cardiovasc Intervent Radiol. 2005;28(4):442-453. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 54.0pt"> <span lang="EN-US" style="color: #231D1D">Rosenthal D, Wellons ED, Lai KM, Bikk  A. Retrievable inferior vena cava filters: Early clinical experience. </span> <span style="color:#231D1D">J Cardiovasc Surg (Torino). 2005;46(2):163-169. </span></p>     ]]></body>
<body><![CDATA[<p class="MsoNormal" style="text-align: justify; margin-left: 54.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="EN-US" style="color: #231D1D">Morris CS, Rogers FB, Najarian KE,  Bhave AD, Shackford SR. Current trends in vena caval filtration with the  introduction of a retrievable filter at a level I trauma center. </span> <span style="color:#231D1D">J Trauma. 2004;57(1):32-36. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="DE" style="color: #231D1D">Lam RC, Bush RL, Lin PH, Lumsden AB. </span><span lang="EN-US" style="color: #231D1D">Early technical and clinical  results with retrievable inferior vena caval filters. Vascular.  2004;12(4):233-237. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="EN-US">Wicky S, Doenz F, Meuwly JY, Portier F, Schnyder P, Denys A.  Clinical experience with retrievable Gunther Tulip vena cava filters. J Endovasc  Ther. 2003;10(5):994-1000. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span style="color:#231D1D">Ishikura K, Yamada N, Oota M, Yazu T, Nakamura M,  Isaka N, et al. </span><span lang="EN-US" style="color: #231D1D">Clinical  experience with retrievable vena cava filters for prevention of pulmonary  thromboembolism. </span><span style="color:#231D1D">J Cardiol.  2002;40(6):267-273. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span style="color:#231D1D">Millward SF, Oliva VL, Bell SD, Valenti DA, Rasuli  P, Asch M, et al. </span><span lang="EN-US" style="color: #231D1D">Gunther Tulip  retrievable vena cava filter: Results from the Registry of the Canadian  Interventional Radiology Association. </span><span style="color:#231D1D">J Vasc  Interv Radiol. 2001;12(9):1053-1058. </span></p>     ]]></body>
<body><![CDATA[<p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="FR" style="color: #231D1D">Ponchon M, Goffette P, Hainaut P.  Temporary vena caval filtration. </span> <span lang="EN-US" style="color: #231D1D">Preliminary clinical experience with  removable vena caval filters. Acta Clin Belg. 1999;54(4):223-228. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span lang="EN-US" style="color: #231D1D">Greenfield LJ, Rutherford RB and the  Participants in the Vena Caval Filter Conference. Recommended reporting  standards for vena caval filter placement and patient follow-up. </span> <span style="color:#231D1D">J Vasc Interv Radiol. 1999;10:10131019. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt">&nbsp;</p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span style="color:#231D1D">Millward SF, Grassi CJ, Kinney TB, Kundu S, Becker  G, Cardella JF, et al. </span><span lang="EN-US" style="color: #231D1D"> Reporting standards for vena caval filter placement and patient follow-up:  Supplement for temporary and retrievable/optional filters. </span> <span style="color:#231D1D">J Vasc Interv Radiol. 2005;16:441-443. </span></p>     <p class="MsoNormal" style="text-align: justify; margin-left: 18.0pt"> <span style="color: #231D1D; font-weight: 700"> ..................................................................................................................................................................................</span></p>     <p style="text-align:justify"><i><span style="color:#231D1D">…viene de la pág.  47. </span></i></p>     <p style="text-align:justify"><span style="color:#231D1D">Después del fatídico  13, la Biblioteca Nacional (Dar al-Kutub wa al-Watha´iq), que ya había sido  sometida a un robo feroz, quedó destruida por un incendio premeditado. Contenía  más de dos millones quinientos mil libros, además de los depósitos legales que  hacían desde 1998. A pesar del esfuerzo de la bibliotecarios y diversos grupos  de voluntarios, que lograron salvar numerosos textos, se quemó un millón de  libros. El Archivo Nacional, localizado en el segundo piso de la biblioteca,  perdió dos millones de documentos, incluidos los del período Otomano. </span> </p>     <p style="text-align:justify"><span style="color:#231D1D">Ardieron más de 700  manuscritos antiguos y 1 500 desaparecieron en la biblioteca Awqaf, cuyo  edificio quedó en ruinas. En la Casa de la Sabiduría (Bayt al-Hikma) cientos de  volúmenes fueron exterminados por el fuego. En la Academia de Ciencias de Iraq  (al-Majma´al-´Ilmi al-Iraqi) el 60 por ciento de los textos se extinguió. La  Universidad de Bagdad fue víctima de bombardeos, incendios y robos. La Madrasa  Mustansiryya fue saqueada, aunque el porcentaje de pérdidas no supera el cuatro  por ciento. </span></p>     ]]></body>
<body><![CDATA[<p style="text-align:justify"><span style="color:#231D1D">En Basora, el Museo de  Historia Natural fue incendiado, lo mismo que la Biblioteca Pública Central, la  Biblioteca de la Universidad y la Biblioteca Islámica. En Mosul, la Biblioteca  del Museo fue víctima de expertos en manuscritos, quienes seleccionaron ciertos  textos y se los llevaron. En Tikrit, las bombas golpearon las estructuras de los  Museos y facilitaron los robos, al provocar la huida de los guardias de  seguridad. </span></p>     <p style="text-align:justify"><i><span style="color:#231D1D">Continúa en la pág.  70… </span></i></p>     <p class="MsoNormal" style="text-align:justify">&nbsp;</p>       ]]></body>
<back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tovey]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Wyatt]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Diagnosis, investigation, and management of deep vein thrombosis]]></article-title>
<source><![CDATA[BMJ.]]></source>
<year>2003</year>
<volume>326</volume>
<page-range>11801184</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bates]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Ginsberg]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Treatment of deep-vein thrombosis]]></article-title>
<source><![CDATA[N Engl J Med.]]></source>
<year>2004</year>
<volume>351</volume>
<page-range>268-277</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fedullo]]></surname>
<given-names><![CDATA[PF]]></given-names>
</name>
<name>
<surname><![CDATA[Tapson]]></surname>
<given-names><![CDATA[VF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The evaluation of suspected pulmonary embolism]]></article-title>
<source><![CDATA[N Engl J Med.]]></source>
<year>2003</year>
<volume>349</volume>
<page-range>12471256</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lin]]></surname>
<given-names><![CDATA[PH]]></given-names>
</name>
<name>
<surname><![CDATA[Bush]]></surname>
<given-names><![CDATA[RL]]></given-names>
</name>
<name>
<surname><![CDATA[Lumsden]]></surname>
<given-names><![CDATA[AB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Vena caval filters in the treatment of acute DVT]]></article-title>
<source><![CDATA[Endovasc Today.]]></source>
<year>2005</year>
<volume>4</volume>
<numero>(1)</numero>
<issue>(1)</issue>
<page-range>40-50</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Binkert]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Bansal]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Gates]]></surname>
<given-names><![CDATA[JD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inferior vena cava filter removal after 317-day implantation]]></article-title>
<source><![CDATA[J Vasc Interv Radiol.]]></source>
<year>2005</year>
<volume>16</volume>
<numero>(3)</numero>
<issue>(3)</issue>
<page-range>395-398</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Haider]]></surname>
<given-names><![CDATA[EA]]></given-names>
</name>
<name>
<surname><![CDATA[Rosen]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Torres]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Valenti]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Serial repositioning of a Gunther Tulip retrievable inferior vena cava filter in a pediatric patient]]></article-title>
<source><![CDATA[Pediatr Radiol.]]></source>
<year>2005</year>
<volume>35</volume>
<numero>(11)</numero>
<issue>(11)</issue>
<page-range>1135-1138</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Terhaar]]></surname>
<given-names><![CDATA[OA]]></given-names>
</name>
<name>
<surname><![CDATA[Lyon]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Given]]></surname>
<given-names><![CDATA[MF]]></given-names>
</name>
<name>
<surname><![CDATA[Foster]]></surname>
<given-names><![CDATA[AE]]></given-names>
</name>
<name>
<surname><![CDATA[Mc Grath]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Extended interval for retrieval of Gunther Tulip filters]]></article-title>
<source><![CDATA[J Vasc Interv Radiol.]]></source>
<year>2004</year>
<volume>15</volume>
<numero>(11)</numero>
<issue>(11)</issue>
<page-range>12571262</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[de Gregorio]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Gamboa]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Gimeno]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Madariaga]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Tobio]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Herrera]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The Gunther Tulip retrievable filter: Prolonged temporary filtration by repositioning within the inferior vena cava]]></article-title>
<source><![CDATA[J Vasc Interv Radiol.]]></source>
<year>2003</year>
<volume>14</volume>
<numero>(10)</numero>
<issue>(10)</issue>
<page-range>1259-1265</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Greenfield]]></surname>
<given-names><![CDATA[LJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evolution of venous interruption for pulmonary thromboembolism]]></article-title>
<source><![CDATA[Arch Surg.]]></source>
<year>1992</year>
<volume>127</volume>
<page-range>622-626</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ochsner]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Ochsner]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Saunders]]></surname>
<given-names><![CDATA[HS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prevention of pulmonary embolism by caval ligation]]></article-title>
<source><![CDATA[Ann Surg.]]></source>
<year>1970</year>
<volume>171</volume>
<page-range>923-938</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Greenfield]]></surname>
<given-names><![CDATA[LJ]]></given-names>
</name>
<name>
<surname><![CDATA[McCrudy]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Brown]]></surname>
<given-names><![CDATA[PP]]></given-names>
</name>
<name>
<surname><![CDATA[Elkins]]></surname>
<given-names><![CDATA[RC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A new intracaval filter permitting continued flow and resolution of emboli]]></article-title>
<source><![CDATA[Surgery.]]></source>
<year>1973</year>
<volume>73</volume>
<page-range>599-606</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kinney]]></surname>
<given-names><![CDATA[TB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Update on inferior vena cava filters]]></article-title>
<source><![CDATA[J Vasc Interv Radiol.]]></source>
<year>2003</year>
<volume>14</volume>
<page-range>425-440</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Darcy]]></surname>
<given-names><![CDATA[MD]]></given-names>
</name>
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[TP]]></given-names>
</name>
<name>
<surname><![CDATA[Hunter]]></surname>
<given-names><![CDATA[DW]]></given-names>
</name>
<name>
<surname><![CDATA[Castaneda-Zuniga]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Lung]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Amplatz]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Short-term prophylaxis of pulmonary embolism by using a retrievable vena cava filter]]></article-title>
<source><![CDATA[Am J Roentgenol.]]></source>
<year>1986</year>
<volume>147</volume>
<page-range>836-838</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yamagami]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Kato]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Lida]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Hirota]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Nishimura]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Gunther Tulip inferior vena cava filter placement during treatment for deep venous thrombosis of the lower extremity]]></article-title>
<source><![CDATA[Cardiovasc Intervent Radiol.]]></source>
<year>2005</year>
<volume>28</volume>
<numero>(4)</numero>
<issue>(4)</issue>
<page-range>442-453</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosenthal]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Wellons]]></surname>
<given-names><![CDATA[ED]]></given-names>
</name>
<name>
<surname><![CDATA[Lai]]></surname>
<given-names><![CDATA[KM]]></given-names>
</name>
<name>
<surname><![CDATA[Bikk]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Retrievable inferior vena cava filters: Early clinical experience]]></article-title>
<source><![CDATA[J Cardiovasc Surg (Torino).]]></source>
<year>2005</year>
<volume>46</volume>
<numero>(2)</numero>
<issue>(2)</issue>
<page-range>163-169</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morris]]></surname>
<given-names><![CDATA[CS]]></given-names>
</name>
<name>
<surname><![CDATA[Rogers]]></surname>
<given-names><![CDATA[FB]]></given-names>
</name>
<name>
<surname><![CDATA[Najarian]]></surname>
<given-names><![CDATA[KE]]></given-names>
</name>
<name>
<surname><![CDATA[Bhave]]></surname>
<given-names><![CDATA[AD]]></given-names>
</name>
<name>
<surname><![CDATA[Shackford]]></surname>
<given-names><![CDATA[SR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Current trends in vena caval filtration with the introduction of a retrievable filter at a level I trauma center]]></article-title>
<source><![CDATA[J Trauma.]]></source>
<year>2004</year>
<volume>57</volume>
<numero>(1</numero>
<issue>(1</issue>
<page-range>32-36</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lam]]></surname>
<given-names><![CDATA[RC]]></given-names>
</name>
<name>
<surname><![CDATA[Bush]]></surname>
<given-names><![CDATA[RL]]></given-names>
</name>
<name>
<surname><![CDATA[Lin]]></surname>
<given-names><![CDATA[PH]]></given-names>
</name>
<name>
<surname><![CDATA[Lumsden]]></surname>
<given-names><![CDATA[AB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Early technical and clinical results with retrievable inferior vena caval filters]]></article-title>
<source><![CDATA[Vascular.]]></source>
<year>2004</year>
<volume>12</volume>
<numero>(4)</numero>
<issue>(4)</issue>
<page-range>233-237</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wicky]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Doenz]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Meuwly]]></surname>
<given-names><![CDATA[JY]]></given-names>
</name>
<name>
<surname><![CDATA[Portier]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Schnyder]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Denys]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical experience with retrievable Gunther Tulip vena cava filters]]></article-title>
<source><![CDATA[J Endovasc Ther.]]></source>
<year>2003</year>
<volume>10</volume>
<numero>(5)</numero>
<issue>(5)</issue>
<page-range>994-1000</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ishikura]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Yamada]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Oota]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Yazu]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Nakamura]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Isaka]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical experience with retrievable vena cava filters for prevention of pulmonary thromboembolism]]></article-title>
<source><![CDATA[J Cardiol.]]></source>
<year>2002</year>
<volume>40</volume>
<numero>(6)</numero>
<issue>(6)</issue>
<page-range>267-273</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Millward]]></surname>
<given-names><![CDATA[SF]]></given-names>
</name>
<name>
<surname><![CDATA[Oliva]]></surname>
<given-names><![CDATA[VL]]></given-names>
</name>
<name>
<surname><![CDATA[Bell]]></surname>
<given-names><![CDATA[SD]]></given-names>
</name>
<name>
<surname><![CDATA[Valenti]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Rasuli]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Asch]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Gunther Tulip retrievable vena cava filter: Results from the Registry of the Canadian Interventional Radiology Association]]></article-title>
<source><![CDATA[J Vasc Interv Radiol.]]></source>
<year>2001</year>
<volume>12</volume>
<numero>(9)</numero>
<issue>(9)</issue>
<page-range>1053-1058</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ponchon]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Goffette]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Hainaut]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Temporary vena caval filtration]]></article-title>
<source><![CDATA[Preliminary clinical experience with removable vena caval filters. Acta Clin Belg.]]></source>
<year>1999</year>
<volume>54</volume>
<numero>(4)</numero>
<issue>(4)</issue>
<page-range>223-228</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Greenfield]]></surname>
<given-names><![CDATA[LJ]]></given-names>
</name>
<name>
<surname><![CDATA[Rutherford]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Recommended reporting standards for vena caval filter placement and patient follow-up]]></article-title>
<source><![CDATA[J Vasc Interv Radiol.]]></source>
<year>1999</year>
<volume>10</volume>
<page-range>10131019</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Millward]]></surname>
<given-names><![CDATA[SF]]></given-names>
</name>
<name>
<surname><![CDATA[Grassi]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
<name>
<surname><![CDATA[Kinney]]></surname>
<given-names><![CDATA[TB]]></given-names>
</name>
<name>
<surname><![CDATA[Kundu]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Becker]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Cardella]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reporting standards for vena caval filter placement and patient follow-up: Supplement for temporary and retrievable/optional filters]]></article-title>
<source><![CDATA[J Vasc Interv Radiol.]]></source>
<year>2005</year>
<volume>16</volume>
<page-range>441-443</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
