<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0535-5133</journal-id>
<journal-title><![CDATA[Investigación Clínica]]></journal-title>
<abbrev-journal-title><![CDATA[Invest. clín]]></abbrev-journal-title>
<issn>0535-5133</issn>
<publisher>
<publisher-name><![CDATA[Instituto de Investigaciones Clínicas "Dr. Américo Negrette", Facultad de Medicina, Universidad del Zulia]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0535-51332003000300006</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Microdiálisis subcutánea: una técnica simple para monitorizar el ambiente bioquímico extracelular. Combinación con electroforesis capilar y detección mediante fluorescencia inducida por láser.]]></article-title>
<article-title xml:lang="en"><![CDATA[Subcutaneous microdialysis: simple technique to monitor biochemical extracellular environment: Coupling with capillary electrophoresis and laser-induced fluorescence detection.]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Páez]]></surname>
<given-names><![CDATA[Ximena]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Mazzei-Dávila]]></surname>
<given-names><![CDATA[Carmen Amalia]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[Luis]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Laboratorio de Fisiologia de la Conducta  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad de Los Andes Facultad de Medicina Departamento de Pediatria]]></institution>
<addr-line><![CDATA[ Mérida]]></addr-line>
<country>Venezuela</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>09</month>
<year>2003</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>09</month>
<year>2003</year>
</pub-date>
<volume>44</volume>
<numero>3</numero>
<fpage>227</fpage>
<lpage>239</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_arttext&amp;pid=S0535-51332003000300006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_abstract&amp;pid=S0535-51332003000300006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_pdf&amp;pid=S0535-51332003000300006&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen. La microdiálisis es una técnica que permite seguir los cambios de sustancias endógenas o exógenas presentes en cualquier compartimento extracelular. Actualmente tiene muchas aplicaciones tanto experimentales como clínicas. El muestreo en el fluido extracelular subcutáneo es especialmente útil para la evaluación del metabolismo en pacientes en condiciones críticas, estudios farmacocinéticos y monitoreo de glucosa. Presentamos algunos ejemplos de estas aplicaciones, usando una cánula fabricada manualmente con un segmento de tubo de celulosa (200 µm de diámetro externo y poros de 13.000 daltons de peso molecular) ensamblado entre tubos de acero inoxidable (26 ga. de diámetro externo) para ser insertada en el tejido subcutáneo, en pacientes en condiciones críticas o en ratones anestesiados, para analizar patrones de aminoácidos por electroforesis capilar con detección mediante fluorescencia inducida por láser (EC-DFIL). También fue usada ambulatoriamente para medir glucosa en voluntarios. Los resultados muestran que la microdiálisis subcutánea es un método muy simple, no costoso ni agresivo, con ventajas sobre la obtención de muestras de sangre por punción venosa repetida e inclusive sobre microdiálisis endovenosa. Este método, combinado con una técnica analítica apropiada, puede usarse exitosamente en la vigilancia del ambiente químico extracelular en condiciones clínicas o preclínicas muy diferentes.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract. Microdialysis is a simple technique that allows monitoring endogenous or exogenous substances in any extracellular compartment. It has many useful experimental and clinical applications. The sampling of the extracellular fluid of the subcutaneous compartment is especially useful for metabolic evaluation in critically ill patients, pharmacokinetic studies and blood glucose monitoring. We built a subcutaneous microdialysis probe, with a cellulose hollow fiber (13,000 molecular weight cut off, 200 µm outside diameter) glued to stainless steel tubing (26 ga. outside diameter). It was implanted in the subcutaneous tissue of a critically ill child or anesthetized mice to obtain amino acids patterns by means of capillary electrophoresis with laser induced fluorescence detection (CE-LIFD). The probe was also implanted in ambulatory volunteers to monitor glucose. The results confirmed that subcutaneous microdialysis is a very simple, inexpensive and not aggressive method with advantages over repeated venipuncture sampling and endovenous microdialysis sampling. The present report shows that subcutaneous microdialysis with the proper analytical technique can be used to monitor the chemical composition of the interstitial compartment in very different preclinical or clinical conditions.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Aminoácidos neutros]]></kwd>
<kwd lng="es"><![CDATA[cromatografía micelar electrocinética]]></kwd>
<kwd lng="es"><![CDATA[glucosa farmacocinética]]></kwd>
<kwd lng="es"><![CDATA[pacientes ambulatorios y hospitalizados]]></kwd>
<kwd lng="es"><![CDATA[ratones]]></kwd>
<kwd lng="en"><![CDATA[Mice]]></kwd>
<kwd lng="en"><![CDATA[human]]></kwd>
<kwd lng="en"><![CDATA[electrokinetic micellar chromatography]]></kwd>
<kwd lng="en"><![CDATA[neutral amino acids]]></kwd>
<kwd lng="en"><![CDATA[glucose]]></kwd>
<kwd lng="en"><![CDATA[pharmacokinetics]]></kwd>
<kwd lng="en"><![CDATA[ambulatory and critically ill patients]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <BASEFONT SIZE="3">     <P align="center" style="margin-top: 0; margin-bottom: 0"><b><font color="#1f1a17" face="Times New Roman" size="4">Microdiálisis subcutánea: una técnica simple para monitorizar el ambiente bioquímico extracelular. Combinación con electroforesis capilar y detección mediante fluorescencia inducida por láser.&nbsp;</font></b></P>     <P align="center"><font face="Times New Roman" size="3"> <FONT COLOR="#1f1a17"> Ximena Páez<SUP>1</SUP>, Carmen Amalia Mazzei-D&#225;vila<SUP>2</SUP> y Luis Hern&#225;ndez<SUP>1</SUP>&nbsp;</FONT></font></P>     <P align="center"><font face="Times New Roman" size="3"><SUP> <FONT COLOR="#1f1a17">1</FONT></SUP><FONT COLOR="#1f1a17">Laboratorio de Fisiología de la Conducta. <SUP>2</SUP>Departamento de Pediatría,      <BR> Facultad de Medicina, Universidad de Los Andes. M&#233;rida, Venezuela.&nbsp;</FONT></font></P>     <P align="justify"> <B></B><B></B></P>     <P align="justify">&nbsp;&nbsp;&nbsp;<font color="#1f1a17" size="3" face="Times New Roman"> <B>Resumen.</B> La microdi&#225;lisis es una t&#233;cnica que permite seguir los cambios  de sustancias end&#243;genas o ex&#243;genas presentes en cualquier compartimento  extracelular. Actualmente tiene muchas aplicaciones tanto experimentales  como cl&#237;nicas. El muestreo en el fluido extracelular subcut&#225;neo es especialmente  &#250;til para la evaluaci&#243;n del metabolismo en pacientes en condiciones cr&#237;ticas,  estudios farmacocin&#233;ticos y monitoreo de glucosa. Presentamos algunos ejemplos  de estas aplicaciones, usando una c&#225;nula fabricada manualmente con un segmento  de tubo de celulosa (200 &#181;m de di&#225;metro externo y poros de 13.000 daltons  de peso molecular) ensamblado entre tubos de acero inoxidable (26 ga. de  di&#225;metro externo) para ser insertada en el tejido subcut&#225;neo, en pacientes  en condiciones cr&#237;ticas o en ratones anestesiados, para analizar patrones  de amino&#225;cidos por electroforesis capilar con detecci&#243;n mediante fluorescencia  inducida por l&#225;ser (EC-DFIL). Tambi&#233;n fue usada ambulatoriamente para medir  glucosa en voluntarios. Los resultados muestran que la microdi&#225;lisis subcut&#225;nea  es un m&#233;todo muy simple, no costoso ni agresivo, con ventajas sobre la  obtenci&#243;n de muestras de sangre por punci&#243;n venosa repetida e inclusive  sobre microdi&#225;lisis endovenosa. Este m&#233;todo, combinado con una t&#233;cnica  anal&#237;tica apropiada, puede usarse exitosamente en la vigilancia del ambiente  qu&#237;mico extracelular en condiciones cl&#237;nicas o precl&#237;nicas muy diferentes.&nbsp;</font></P>     <P align="justify"><font face="Times New Roman" size="3"><B><FONT COLOR="#1f1a17">Palabras clave:&nbsp;</FONT></B><FONT COLOR="#1f1a17" face="Times New Roman">Amino&#225;cidos neutros, cromatograf&#237;a micelar electrocin&#233;tica, glucosa farmacocin&#233;tica,  pacientes ambulatorios y hospitalizados, ratones</FONT></font></P> </MULTICOL> <MULTICOL GUTTER="31" COLS="2">     <P align="center">&nbsp;</P>     <P align="center"><font face="Times New Roman" size="3"> <B><FONT COLOR="#1f1a17"> Subcutaneous microdialysis: simple technique to monitor biochemical extracellular  environment. Coupling with capillary electrophoresis and </FONT></B><FONT COLOR="#1f1a17"> <B>  laser-induced  fluorescence detection.    ]]></body>
<body><![CDATA[<BR>  </B> </FONT></font></P>     <P align="justify"><font face="Times New Roman" size="3"><B><FONT COLOR="#1f1a17">&nbsp;&nbsp;&nbsp; Abstract</FONT></B><FONT COLOR="#1f1a17" face="Times New Roman">. Microdialysis is a simple technique that allows monitoring endogenous  or exogenous substances in any extracellular compartment. It has many useful  experimental and clinical applications. The sampling of the extracellular  fluid of  the subcutaneous compartment is especially useful for metabolic  evaluation in critically ill patients, pharmacokinetic studies and blood  glucose monitoring. We built a subcutaneous microdialysis probe, with a  cellulose hollow fiber (13,000 molecular weight cut off, 200 &#181;m outside  diameter) glued to stainless steel tubing (26 ga. outside diameter). It  was implanted in the subcutaneous tissue of a critically ill child or anesthetized  mice to obtain amino acids patterns by means of capillary electrophoresis  with laser induced fluorescence detection (CE-LIFD). The probe was also  implanted in ambulatory volunteers to monitor glucose. The results confirmed  that subcutaneous microdialysis is a very simple, inexpensive and not aggressive  method with advantages over repeated venipuncture sampling and endovenous  microdialysis sampling. The present report shows that subcutaneous microdialysis  with the proper analytical technique can be used to monitor the chemical  composition of the interstitial compartment in very different preclinical  or clinical conditions.&nbsp;</FONT></font></P>     <P align="justify"><font face="Times New Roman" size="3"><B><FONT COLOR="#1f1a17">Key words:&nbsp;</FONT></B><FONT COLOR="#1f1a17" face="Times New Roman">Mice, human, electrokinetic micellar chromatography, neutral amino acids, glucose, pharmacokinetics, ambulatory and critically ill patients</FONT></font></P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> Recibido: 14-10-2002. Aceptado: 05-06-2003.&nbsp; </FONT></P>     <p align="justify"><font face="Times New Roman" size="3">    <BR> <FONT COLOR="#1f1a17"> <B>INTRODUCCI&#211;N&nbsp;</B> </FONT></font>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; La microdi&#225;lisis consiste en el intercambio de mol&#233;culas a trav&#233;s de una  membrana porosa, siguiendo gradientes de concentraci&#243;n, lo que permite  extraer o introducir sustancias en matrices qu&#237;micas complejas. Esta t&#233;cnica  ha sido de gran utilidad en el control o vigilancia de compuestos libres,  de bajo peso molecular, presentes en el medio extracelular. Se puede realizar  pr&#225;cticamente en cualquier tejido o fluido biol&#243;gico. Actualmente la microdi&#225;lisis  tiene una gran aplicaci&#243;n tanto en investigaci&#243;n b&#225;sica en animales de  experimentaci&#243;n as&#237; como en investigaci&#243;n, diagn&#243;stico y terap&#233;utica en  humanos (1-5). Esto se evidencia en el gran n&#250;mero de publicaciones sobre  sus aplicaciones en los &#250;ltimos a&#241;os (5). La microdi&#225;lisis inicialmente  se emple&#243; en estudios neuroqu&#237;micos en el cerebro de animales (6). Posteriormente,  su aplicaci&#243;n en farmacocin&#233;tica ha sido de gran utilidad. Se ha analizado  drogas de muy diferente naturaleza con el muestreo simult&#225;neo de uno o  m&#225;s compartimientos extracelulares: m&#250;sculo, sangre, h&#237;gado, o tejido subcut&#225;neo,  tanto en animales como en humanos (7-13). La microdi&#225;lisis tambi&#233;n ha sido  usada en el h&#237;gado para monitorear el metabolismo despu&#233;s de transplante  hep&#225;tico (14), en mama para estudiar cambios metab&#243;licos durante el ciclo  menstrual (15), o en el tejido adiposo subcut&#225;neo para vigilar cambios  metab&#243;licos durante la anestesia (16).&nbsp; </FONT></P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; El uso de la microdi&#225;lisis en la cl&#237;nica ha aumentado en los &#250;ltimos a&#241;os,  especialmente en pacientes en estado cr&#237;tico, por ser una t&#233;cnica pr&#225;cticamente  inocua. La microdi&#225;lisis cerebral se ha empleado para evaluar el metabolismo  y los neurotransmisores en el medio extracelular cerebral, en pacientes  que padecen trauma encef&#225;lico, durante la neurocirug&#237;a, en la enfermedad  cerebro vascular y en otras patolog&#237;as neurol&#243;gicas. Los cambios encontrados  en estas diversas condiciones han permitido identificar marcadores del  estado energ&#233;tico de las c&#233;lulas, o de excitotoxicidad, as&#237; como identificar  cambios regionales en neurotransmisores (1, 4, 17-21).&nbsp; </FONT></P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; En los pacientes gravemente enfermos, interesa conocer los cambios qu&#237;micos  r&#225;pidos que pueden ocurrir en el medio extracelular en diferentes tejidos  y que son causados por drogas o por determinada condici&#243;n fisiopatol&#243;gica,  a fin de tomar medidas terape&#250;ticas precoces y apropiadas. El monitoreo  o vigilancia continuos con microdi&#225;lisis permitir&#237;a detectar por ejemplo,  sustancias end&#243;genas que podr&#237;an ser indicadores del curso de una enfermedad  o condici&#243;n particular, o los niveles t&#243;xicos de sustancias end&#243;genas o  drogas. Esto se puede hacer con microdi&#225;lisis endovenosa in vivo <I> </I>(10, 22,  23)<I>,</I> pero se necesita tomar y mantener una v&#237;a venosa, o si se hace microdi&#225;lisis in vitro en muestras de plasma, se necesita hacer extracciones repetidas  de sangre por punci&#243;n de una vena o de un cat&#233;ter endovenoso y luego dializar  el plasma (10).&nbsp; </FONT></P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; Una forma m&#225;s sencilla y m&#225;s precisa de analizar el medio ambiente extracelular  con microdi&#225;lisis es sondear los tejidos perif&#233;ricos como el tejido celular  subcut&#225;neo (11). Este compartimento es de f&#225;cil acceso y las complicaciones  o riesgos para el paciente son menores. La microdi&#225;lisis subcut&#225;nea desde  sus inicios se ha aplicado al estudio de los cambios metab&#243;licos en el  intersticio como la evaluaci&#243;n del metabolismo de la glucosa y de los l&#237;pidos  (24, 25). Ha sido muy &#250;til en estudios metab&#243;licos de glucosa, lactato  y glutamato en pacientes neurol&#243;gicos en estado cr&#237;tico, y ha proporcionado  datos que pueden contribuir a la interpretaci&#243;n de lo que est&#225; ocurriendo  en el cerebro (26). Tambi&#233;n se ha usado para monitorizar el metabolismo  en los bordes de piel para dar informaci&#243;n sobre el futuro de la viabilidad  de un injerto (27), el metabolismo subcut&#225;neo en pacientes con citopat&#237;a  mitocondrial (28), durante la anestesia (16), y el metabolismo de amino&#225;cidos  en reci&#233;n nacidos (29). La informaci&#243;n del metabolismo del medio intersticial  puede mostrar cambios en algunos indicadores aun antes que en la sangre,  o de que ocurran manifestaciones cl&#237;nicas lo que da ventaja para una r&#225;pida  intervenci&#243;n terap&#233;utica (30). Otra de las importantes aplicaciones de  la microdi&#225;lisis cut&#225;nea es en estudios farmacocin&#233;ticos, en los que se  puede medir directamente las concentraciones de la droga en el tejido.  Estos estudios antes estaban limitados a las medidas de concentraci&#243;n de  la droga en el plasma o en la sangre. Se han estudiado diversas drogas  como por ejemplo, antibi&#243;ticos, antiepil&#233;pticos (11) antiinflamatorios  (31) y antineopl&#225;sicos como el 5-fluoracilo (32). En pacientes en estado  cr&#237;tico conocer la farmacocin&#233;tica de antibi&#243;ticos u otros medicamentos  puede dar informaci&#243;n mejor que la del plasma, ya que el intersticio es  el sitio donde la mayor&#237;a de los medicamentos act&#250;a (11, 33). Los datos  de concentraciones de drogas en plasma pueden hacer que el m&#233;dico use err&#243;neamente  una dosis potencialmente inferior a la necesaria.&nbsp; </FONT></P>     ]]></body>
<body><![CDATA[<P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; El desarrollo de esta t&#233;cnica ha significado el progreso en una de sus  aplicaciones m&#225;s exitosas: el monitoreo continuo de glucosa en pacientes  graves y ambulantes, sin tener que hacer extracci&#243;n repetida de sangre.  La microdi&#225;lisis subcut&#225;nea permite tener una mejor evaluaci&#243;n de cambios  extremos en la glucosa, que pueden ir desde detecci&#243;n de hipoglicemia hasta  decidir administrar insulina (34). Es especialmente &#250;til si se trata de monitoreo de glucosa a largo plazo (d&#237;as) en reci&#233;n nacidos, pues se evita  la p&#233;rdida de sangre y el estr&#233;s de la extracci&#243;n de sangre en estos peque&#241;os  pacientes (35). Actualmente, la combinaci&#243;n de microdi&#225;lisis subcut&#225;nea  ultralenta con nanosensores de glucosa se usa en la terapia intensiva de  diab&#233;ticos (36). La microdi&#225;lisis subcut&#225;nea tambi&#233;n ha sido usada en estudios  del &#243;xido n&#237;trico y de su papel en la vasodilataci&#243;n e inflamaci&#243;n del  tejido subcut&#225;neo (37, 38) as&#237; como en la evaluaci&#243;n de la administraci&#243;n  t&#243;pica o sist&#233;mica de drogas (39).&nbsp; </FONT></P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; Las muestras de microdi&#225;lisis en general, son de muy peque&#241;o volumen y  con analitos en bajas concentraciones, lo que hace necesario disponer de  t&#233;cnicas anal&#237;ticas muy sensibles tales como la electroforesis capilar  (EC). Esta es una t&#233;cnica anal&#237;tica que permite separar, identificar y  cuantificar sustancias en peque&#241;os vol&#250;menes y esto permite aumentar la  resoluci&#243;n temporal de la microdi&#225;lisis (32, 40-43). De modo que, la combinaci&#243;n  de microdi&#225;lisis subcut&#225;nea y EC-DFIL resulta muy conveniente para el an&#225;lisis  en vol&#250;menes de muy pocos microlitros y aun nanolitros lo cual no es posible  con otras t&#233;cnicas anal&#237;ticas como la cromatograf&#237;a l&#237;quida de alta presi&#243;n  (44).&nbsp; </FONT></P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; En el presente trabajo mostramos algunos ejemplos de las aplicaciones de  una c&#225;nula de microdi&#225;lisis subcut&#225;nea de muy simple dise&#241;o y f&#225;cil fabricaci&#243;n  que puede usarse tanto en roedores y como en humanos. Usamos microdi&#225;lisis  subcut&#225;nea en una vigilancia continua y simult&#225;nea de varios amino&#225;cidos  en un paciente pedi&#225;trico en coma, y en ratones anestesiados. El an&#225;lisis  de las muestras se hizo con EC-DFIL. Tambi&#233;n empleamos nuestra c&#225;nula en  j&#243;venes voluntarios sanos durante una prueba de carga oral de glucosa y  comparamos los datos de di&#225;lisis con los de sangre en los mismos individuos.  Los resultados confirmaron que la microdi&#225;lisis subcut&#225;nea es una t&#233;cnica  muy sencilla, sin riesgos para el paciente, m&#225;s conveniente que la microdi&#225;lisis  en sangre in vivo o in vitro. La combinaci&#243;n con EC-DFIL tambi&#233;n demostr&#243;  ser muy conveniente especialmente cuando se trata de estudios en pacientes  pedi&#225;tricos o en animales muy peque&#241;os donde es ventajoso el uso de peque&#241;os  vol&#250;menes de muestra.&nbsp; </FONT></P>     <P align="justify"><font face="Times New Roman" size="3"><B><FONT COLOR="#1f1a17"> MATERIAL Y M&#201;TODOS</FONT></B><FONT COLOR="#1f1a17" face="Times New Roman">&nbsp;</FONT></font></P>     <P align="justify"> <B><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> C&#225;nula de microdi&#225;lisis subcut&#225;nea&nbsp;</FONT></B> </P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; En la <a href="#fig1"> Fig. 1</a> se muestra el diagrama de la c&#225;nula para microdi&#225;lisis subcut&#225;nea.  Estas c&#225;nulas fueron fabricadas manualmente con un segmento de 15 mm de  fibra hueca de celulosa con poros permeables a mol&#233;culas de PM inferior  a 13.000 daltons insertado entre 2 trozos de tubo de acero inoxidable 26  ga de 2 cm de largo. Para la adhesi&#243;n de las uniones se us&#243; cemento epoxy<I>.  </I>El extremo libre en bisel de uno de los segmentos de acero inoxidable sirvi&#243;  para punzar la piel e introducir la c&#225;nula.&nbsp; </FONT></P>     <P align="center"><a name="fig1"><img border="0" src="/img/fbpe/ic/v44n3/art06fig1.jpg" align="center" width="317" height="233"> </a> </P>     
<P align="center">Fig. 1. Microdiálisis subcutánea. A. Diseño e implantación de la cánula. B. Diálisis a través del tubo de celulosa colocado en el tejido subcutáneo. La bomba de infusión se conecta a la entrada de la cánula y del extremo de salida se recoge el dializado. </P>     <P align="justify">&nbsp; </P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman">     ]]></body>
<body><![CDATA[<BR> </FONT> <B><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> Sujetos y di&#225;lisis&nbsp; </FONT></B> </P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; 1.&nbsp;En un ni&#241;o politraumatizado en coma, hospitalizado en la unidad de cuidados  intensivos pedi&#225;tricos del Hospital Universitario de los Andes, luego de  obtener la autorizaci&#243;n de los m&#233;dicos tratantes y el representante legal  del paciente, previa informaci&#243;n del procedimiento, bajo asepsia y antisepsia  se insert&#243; una c&#225;nula en la piel periumbilical, de tal forma que el segmento  de di&#225;lisis qued&#243; implantado en el tejido subcut&#225;neo como se muestra en  la <a href="#fig1"> Fig.&nbsp;1</a>. La c&#225;nula fue conectada a una bomba de perfusi&#243;n y se perfundi&#243;  con NaCl 0,9% a 1 mL/min. Se hizo una di&#225;lisis continua recogiendo muestras  de 60 mL/60 min en 49 horas (49 muestras en total) durante las cuales el  estado de conciencia del paciente cambi&#243; hacia la mejor&#237;a (de 6 a 10 en  la escala de Glasgow). Las muestras se guardaron a &#150;80&#176;C hasta ser procesadas.  El proceso de di&#225;lisis no interfiri&#243; con el cuidado m&#233;dico del paciente.&nbsp;</FONT></P> </MULTICOL> <MULTICOL GUTTER="31" COLS="2">     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; 2.&nbsp;A 4 ratones albinos machos adultos, de la l&#237;nea NMRI, de peso entre 20  a 22 g anestesiados con clorhidrato de ketamina (100 mg/kg) se les implant&#243;  una c&#225;nula de microdi&#225;lisis cut&#225;nea en el hemiabdomen izquierdo de modo  que el segmento funcional qued&#243; inmerso en el tejido subcut&#225;neo y luego  se procedi&#243; a perfundir la c&#225;nula de la manera descrita en 1. Se tomaron  muestras cada 30 minutos durante 2 horas (12 muestras en total). Durante  todo el procedimiento de di&#225;lisis los animales estuvieron anestesiados.  Las muestras se guardaron a &#150;80&#176;C hasta su procesamiento.&nbsp;</FONT></P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; 3.&nbsp;En 10 voluntarios sanos en ayunas, de sexo masculino entre 18 y 24 a&#241;os  de edad, luego de explicar el procedimiento y obtener el consentimiento  informado por escrito de cada voluntario, bajo condiciones de asepsia y  antisepsia se les implant&#243; en la cara anterior del antebrazo derecho una  c&#225;nula de di&#225;lisis subcut&#225;nea que se conect&#243; y que fue perfundida de la  manera descrita anteriormente. Se tomaron muestras cada 30 minutos. Despu&#233;s  de tomar la primera muestra de di&#225;lisis se administr&#243; por v&#237;a oral 75 g  glucosa y se tom&#243; una muestra de sangre por venopunci&#243;n en el brazo izquierdo.  Luego cada 30 min. se recogi&#243; un dializado y una muestra de sangre heparinizada  hasta los 120 min. Las muestras se mantuvieron en hielo hasta ser procesadas  el mismo d&#237;a.&nbsp;</FONT></P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; 4.&nbsp;Para realizar di&#225;lisis in vitro de plasma humano obtenido de sujetos sanos  voluntarios, se separ&#243; el plasma por centrifugaci&#243;n de muestras heparinizadas  de sangre tomada por punci&#243;n de venas del codo. Se coloc&#243; una c&#225;nula de  di&#225;lisis conc&#233;ntrica (45) con 15 mm de &#225;rea funcional (celulosa) dentro  de un tubo con 500 ml de plasma. La celulosa empleada y las condiciones  de di&#225;lisis son las mismas que las descritas anteriormente.    <BR> &nbsp;</FONT></P>     <P align="justify"> <B><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> An&#225;lisis de las muestras&nbsp; </FONT></B> </P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; 1.&nbsp;Los dializados subcut&#225;neos de ni&#241;o y de rat&#243;n fueron procesados para analizar  amino&#225;cidos por EC-DFIL (45, 46). En breve, la t&#233;cnica anal&#237;tica consisti&#243;  en derivatizar las muestras con isotiocianato de fluoresce&#237;na para hacerlas  fluorescentes. Luego de 18 horas de incubaci&#243;n las muestras fueron analizadas  en un equipo de EC con un l&#225;ser de arg&#243;n (Meridialysis CZE system) (47).  Este sistema permite el an&#225;lisis en m&#237;nimos vol&#250;menes de muestras que se  cargan por presi&#243;n negativa en uno de los extremos del capilar. A las soluciones  de corrida usadas se les a&#241;adi&#243; detergente (lauril sulfato de sodio) para  formar micelas a fin de separar amino&#225;cidos neutros que no se resolver&#237;an  con la EC convencional. Este proceso se conoce como cromatograf&#237;a electrocin&#233;tica  micelar, y es una variante de la electroforesis capilar (46). Los valores  de fluorescencia de cada amino&#225;cido (alturas de picos) obtenidos con EC-DFIL  en las muestras del ni&#241;o fueron convertidos a concentraci&#243;n expresada en  micromoles por litro por comparaci&#243;n con los valores de fluorescencia de  soluciones de concentraci&#243;n conocida (patr&#243;n) para cada amino&#225;cido.&nbsp;</FONT></P> </MULTICOL>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp;&nbsp; 2.&nbsp;Los dializados subcut&#225;neos y las muestras de sangre de los voluntarios  fueron analizados autom&#225;ticamente con un analizador de glucosa por el m&#233;todo  enzim&#225;tico convencional. Se calcularon los valores promedios de glucosa  en mg% para cada punto de las curvas de glucosa en dializados y de glucosa  en plasma. Se hizo el an&#225;lisis estad&#237;stico de las curvas con ANOVA one  way y el test pos hoc de Tukey.&nbsp;</FONT></P>     <P align="justify"><font face="Times New Roman" size="3"><B><FONT COLOR="#1f1a17"> RESULTADOS</FONT></B><FONT COLOR="#1f1a17"><B>&nbsp;</B> </FONT></font></P>     ]]></body>
<body><![CDATA[<P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; La implantaci&#243;n de c&#225;nula de di&#225;lisis no ocasion&#243; riesgos ni molestias  a los sujetos durante ni despu&#233;s de la di&#225;lisis. Fue posible dializar continuamente  por el tiempo deseado, mientras que existiera aporte continuo de la soluci&#243;n  de perfusi&#243;n. El ni&#241;o en cuidados intensivos se dializ&#243; durante 49 horas  continuas sin interferir con los cuidados m&#233;dicos del paciente. En la <a href="#fig2"> Fig.  2</a> se muestra un patr&#243;n t&#237;pico de separaci&#243;n de los amino&#225;cidos: isoleucina  (Ile), valina (Val), fenilalanina (Phe), treonina (Thr), Gaba, alanina  (Ala) y serina (Ser). Todos amino&#225;cidos neutros o apolares, excepto la  serina (Ser) y presentes en un dializado subcut&#225;neo. Este monitoreo permiti&#243;  adem&#225;s obtener simult&#225;neamente el curso temporal de cambios en los amino&#225;cidos  analizados (<a href="#fig3">Fig. 3</a>). En la <a href="#fig4"> Fig. 4</a> se muestran relaciones entre algunos  de los amino&#225;cidos analizados. Por ejemplo, la relaci&#243;n Val/Phe se elev&#243;  a partir de las 18 horas, incremento que coincidi&#243; con la mejor&#237;a neurol&#243;gica  del paciente (de 6 a 10 seg&#250;n la escala de Glasgow), mientras la relaci&#243;n  Ser/ Ala se mantuvo sin cambios. Por otra parte, la di&#225;lisis subcut&#225;nea  en los ratones (<a href="#fig5">Fig. 5 arriba</a>) mostr&#243; en los electroferogramas de los mismos  amino&#225;cidos, un patr&#243;n muy semejante al obtenido en el ni&#241;o. Adem&#225;s se  encontr&#243; similitud en estos patrones de dializados subcut&#225;neos con los  de dializados de plasma<I> </I>humano obtenidos in vitro (<a href="#fig5">Fig. 5 abajo</a>).&nbsp; </FONT></P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; La di&#225;lisis subcut&#225;nea en voluntarios sanos se realiz&#243; sin ninguna molestia  para el sujeto y al final, luego de retirar la c&#225;nula, fue pr&#225;cticamente  imperceptible el sitio de la di&#225;lisis. Fue menos molesta que la di&#225;lisis  endovenosa, la cual requiere punzar y canular una vena y luego mantener  la permeabilidad del cat&#233;ter endovenoso (gu&#237;a para la implantaci&#243;n de c&#225;nula  de di&#225;lisis endovenosa), y de la vena (10). En la <a href="#fig6"> Fig. 6</a> se muestran las  curvas de respuesta a la carga oral de glucosa en los dializados y en la  sangre venosa perif&#233;rica. En ambas curvas se observ&#243; la elevaci&#243;n significativa  de glucosa [F=4,3 (4,45) p &lt; 0,05] en dializados y [F=10,6 (4,45) p &lt; 0,001]  en plasma. El aumento no fue simult&#225;neo. En la sangre ocurri&#243; a los 30  min y en los dializados a los 60 min, lo que indica las diferencias de  distribuci&#243;n en los distintos compartimientos, pues la glucosa una vez  absorbida va primero a la sangre y luego pasa a los tejidos (48). Adem&#225;s  existe una variaci&#243;n sustancial interindividual de recuperaci&#243;n de glucosa  que hace dif&#237;cil precisar exactamente el desfase temporal fisiol&#243;gico entre  ambos compartimentos (49). La recuperaci&#243;n de glucosa en el dializado subcut&#225;neo,  con las c&#225;nulas y flujo empleados, fue aproximadamente de un 30% de lo  obtenido en sangre. Los datos de glucosa en dializados se presentaron corregidos  por el porcentaje de recuperaci&#243;n.&nbsp; </FONT></P> </MULTICOL>     <P align="center"><a name="fig2"><img border="0" src="/img/fbpe/ic/v44n3/art06fig2.jpg" align="center" width="315" height="322"></a></P>     
<P align="justify">&nbsp;</P>     <p align="center"><font face="Times New Roman" size="3">Fig. 2. Patrón de3 aminoácidos en un dializado subcutáneo humano. Análisis mediante EC-DFIL con una solución buffer con detergente que permite separar aminoácidos neutros o apolares.<b>Arriba: </b>Electroferograma completo. <b>Abajo: </b>Magnificación de un segmento de un minuto del electroferograma que muestra el patrón típico de separación de 7 aminoácidos: isoleucina (Ile), valina (Val), fenilalanina (Phe), treonina (Thr), Gaba, serina (Ser) y alanina (Ala).<b> </b> </font>     <P align="justify">  &nbsp;  </P>     <P align="center"><a name="fig3"><img border="0" src="/img/fbpe/ic/v44n3/art06fig3.jpg" align="center" width="475" height="252"></a></P>     
<P align="justify">&nbsp;</P>     <p align="center"><font face="Times New Roman" size="3">Fig 3. Control simultáneo de la concentración de cuatro aminoácidos en dializados subcutáneos obtenidos en cada hora durante 49 horas de un niño politraumatizado hospitalizado en una unidad de cuidados intensivos.&nbsp;</font>     <p align="center">&nbsp;     ]]></body>
<body><![CDATA[<p align="center">&nbsp;     <p align="center"><font face="Times New Roman" size="3"> &nbsp;<a name="fig4"><img border="0" src="/img/fbpe/ic/v44n3/art06fig4.jpg" align="center" width="454" height="266"></a></font>     
<P align="center">Fig. 4. Razones entre aminoácidos&nbsp; medidos con EC-DFIL en muestras obtenidas durante 49 horas de microdiálisis subcutánea</P>     <P align="center"><a name="fig5"><img border="0" src="/img/fbpe/ic/v44n3/art06fig5.jpg" align="center" width="410" height="389"></a></P>     
<P align="center"><font face="Times New Roman" size="3">Fig. 5. Patrón de aminoácidos en microdializados analizados con EC-DFIL. <b>Arriba. </b>Dializado subcutáneo de ratón anestesiado. <b>Abajo.</b>Dializado in vitro de plasma humano.</font></P>     <P align="justify">&nbsp;</P>     <P align="center"><a name="fig6"><img border="0" src="/img/fbpe/ic/v44n3/art06fig6.jpg" align="center" width="299" height="307"></a></P>     
<P align="center"><font face="Times New Roman" size="3">Fig. 6. Glucosa en voluntarios sanos (n=10) a los 0,30,60,90 y 120 min luego de una carga oral de 75g de glucosa <b>A. </b>Curva de glucosa plasmática. <b>B. </b>Curva de glucosa en dializados subcutáneos. **p&lt;0,001 *p&lt;0,05.</font></P>     <P align="justify">&nbsp;</P>     <P align="justify"><font face="Times New Roman" size="3"><B><FONT COLOR="#1f1a17"> DISCUSIÓN</FONT></B><FONT COLOR="#1f1a17"><B>&nbsp;</B> </FONT></font></P>     ]]></body>
<body><![CDATA[<P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; La evaluaci&#243;n del ambiente bioqu&#237;mico extracelular es de gran inter&#233;s no  s&#243;lo en la investigaci&#243;n b&#225;sica sino en la cl&#237;nica, lo que se evidencia  en el creciente n&#250;mero de publicaciones sobre aplicaciones cl&#237;nicas de  la microdi&#225;lisis. M&#252;ller menciona que hay m&#225;s de siete mil art&#237;culos sobre  microdi&#225;lisis y m&#225;s de mil art&#237;culos en humanos (5). Nosotros encontramos  alrededor de 100 art&#237;culos en los &#250;ltimos 4 a&#241;os s&#243;lo en microdi&#225;lisis  subcut&#225;nea en humanos. El uso de di&#225;lisis simult&#225;nea en tejidos perif&#233;ricos  ha tenido gran aplicaci&#243;n en estudios farmacocin&#233;ticos pues la concentraci&#243;n  de las drogas en estos compartimientos perif&#233;ricos es lo que determina  la efectividad de la terap&#233;utica, m&#225;s que la concentraci&#243;n en el plasma.  Antes de la introducci&#243;n de la microdi&#225;lisis, los estudios farmacocin&#233;ticos  estaban limitados a mediciones de drogas en plasma por ser &#233;ste el &#250;nico  compartimento d&#243;nde se pod&#237;an medir f&#225;cilmente las drogas (11). Pero con  la microdi&#225;lisis esto ha cambiado. La microdi&#225;lisis endovenosa se ha usado  con frecuencia especialmente en los pacientes cr&#237;ticamente enfermos para monitorizar cambios en sustancias ex&#243;genas y end&#243;genas, y tomar medidas  correctivas r&#225;pidas durante el monitoreo (50). Esta microdi&#225;lisis requiere  canular una vena y mantener la permeabilidad de la v&#237;a. En algunos casos  &#233;sto no es f&#225;cil, porque son ni&#241;os muy peque&#241;os reci&#233;n nacidos o prematuros  en los cuales colocar una c&#225;nula m&#225;s, puede ser excesivamente traum&#225;tico.  T&#233;cnicamente es m&#225;s dif&#237;cil hacer coincidir los tama&#241;os adecuados de cat&#233;teres  endovenosos (gu&#237;as) y la c&#225;nula de di&#225;lisis que tiene que ir adentro, aunado  a que puede haber m&#225;s riesgo de infecci&#243;n cuando se usa la v&#237;a venosa.  Adem&#225;s, como mencionamos antes, las mediciones en plasma no son necesariamente  las mejores para indicar las concentraciones efectivas de una droga en  los tejidos.&nbsp; </FONT></P> </MULTICOL>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; Por otra parte tenemos que el sondeo subcut&#225;neo por microdi&#225;lisis es m&#225;s  simple, las c&#225;nulas f&#225;ciles de fabricar e implantar, el procedimiento poco  o nada agresivo sin riesgos secundarios, f&#225;cil de mantener continuamente  por horas o d&#237;as, y como en cualquier otra microdi&#225;lisis, se puede analizar  cualquier sustancia presente en el dializado dependiendo del tama&#241;o de  los poros de la membrana de di&#225;lisis y de la t&#233;cnica anal&#237;tica que se disponga.  Hacer microdi&#225;lisis subcut&#225;nea es m&#225;s conveniente que tomar muestras repetidas  de sangre, especialmente si el individuo tiene un volumen de sangre bajo  como en un prematuro. M&#225;s a&#250;n, la microdi&#225;lisis subcut&#225;nea causa pocas  molestias al paciente y permite examinar las concentraciones de los analitos  de inter&#233;s, drogas o compuestos end&#243;genos en el intersticio, que es d&#243;nde  act&#250;an y d&#243;nde interesa evaluarlos. Cuando se acopla la microdi&#225;lisis a  una t&#233;cnica anal&#237;tica de alta resoluci&#243;n como la EC-DFIL se puede hacer  los an&#225;lisis bioqu&#237;micos de diversas sustancias simult&#225;neamente en vol&#250;menes  peque&#241;os de muestras mejorando as&#237; la resoluci&#243;n temporal de la microdi&#225;lisis.&nbsp; </FONT></P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; El an&#225;lisis con EC-DFIL de los dializados subcut&#225;neos, permiti&#243; separar,  identificar y medir continuamente: Ile, Val, Phe, Thr, Gaba, Ser, Ala,  los cuales se presentaron en un patr&#243;n similar al encontrado en dializados  de plasma obtenidos in vitro. En el ni&#241;o en estado cr&#237;tico hubo cambios  en los analitos que coincidieron con cambios en su estado cl&#237;nico (mejor&#237;a  neurol&#243;gica de 6 a 10 en la escala de Glasgow). Aunque no se puede dar  una explicaci&#243;n precisa para estos hallazgos, se trata justamente de descubrir,  mediante este tipo de monitoreo<I>,</I> indicadores pron&#243;sticos en el curso de  una enfermedad o condici&#243;n determinada, para tomar medidas terap&#233;uticas  precoces si fuera necesario. En un estudio en ni&#241;os con trauma encef&#225;lico,  Tolias y col. (51), reportan cambios en las proporciones de amino&#225;cidos  neuroactivos en dializados cerebrales, algunos de los cuales se asocian  unos con aumento de morbilidad y otros con mejor&#237;a cl&#237;nica; mientras que  en amino&#225;cidos estructurales no reportan cambios. Se encontr&#243;, adem&#225;s,  una gran similitud en los patrones electroferogr&#225;ficos de los dializados  del tejido celular subcut&#225;neo del ni&#241;o y de los dializados de plasma humanos  obtenidos in vitro. Esto indicar&#237;a que el arreglo bioqu&#237;mico extracelular  del tejido subcut&#225;neo es semejante al del plasma al menos en estos amino&#225;cidos  analizados, por lo que el muestreo extracelular del tejido subcut&#225;neo podr&#237;a  ser otra opci&#243;n para el estudio del ambiente bioqu&#237;mico intravascular,  especialmente cuando no es posible o conveniente el uso del plasma. El  an&#225;lisis de glucosa en voluntarios tambi&#233;n mostr&#243; que tanto en pacientes  cr&#237;ticamente enfermos como ambulatoriamente este m&#233;todo es f&#225;cil de realizar  sin riesgos para los sujetos.&nbsp; </FONT></P> </MULTICOL>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; En conclusi&#243;n, la microdi&#225;lisis subcut&#225;nea pudo usarse en un paciente cr&#237;ticamente  enfermo o en voluntarios ambulatorios sin riesgos y sin molestias. As&#237;  mismo, permiti&#243; el reconocimiento de patrones de amino&#225;cidos con EC-DFIL,  los cuales resultaron ser similares en diferentes compartimientos y especies.  Esta semejanza de los dializados subcut&#225;neos con los dializados de plasma,  al menos en cuanto a amino&#225;cidos, indica que podr&#237;a usarse el control bioqu&#237;mico  subcut&#225;neo en sustituci&#243;n del control bioqu&#237;mico del plasma. La microdi&#225;lisis  subcut&#225;nea combinada con EC-DFIL es pues una alternativa efectiva y conveniente  para el control bioqu&#237;mico del medio interno.&nbsp; </FONT></P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; Para el futuro muy cercano se anticipa mayor uso de microdi&#225;lisis en tejidos  perif&#233;ricos a flujos muy lentos, para aumentar la recuperaci&#243;n de los analitos  hasta pr&#225;cticamente el 100%, combinada con sensibles t&#233;cnicas anal&#237;ticas  en l&#237;nea, es decir, hacer el an&#225;lisis qu&#237;mico a medida que se va obteniendo  la muestra, permitiendo una r&#225;pida recolecci&#243;n de datos con alta resoluci&#243;n  temporal al lado de la cama del paciente (52-53).&nbsp; </FONT></P>     <P align="justify"><font face="Times New Roman" size="3"> <B><FONT COLOR="#1f1a17"> AGRADECIMIENTO</FONT></B><FONT COLOR="#1f1a17"><B>&nbsp;</B> </FONT></font></P>     <P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> &nbsp;&nbsp;&nbsp; Este trabajo se ejecut&#243; con financiamiento otorgado por el CONICIT proyecto  # G 97000820. Agradecemos al personal m&#233;dico y de enfermer&#237;a de la Unidad  de Cuidados Intensivos Pedi&#225;tricos del Hospital Universitario de los Andes  (HULA) M&#233;rida, Venezuela, por su colaboraci&#243;n para realizar microdi&#225;lisis  en sus pacientes.&nbsp; </FONT></P>     <P align="justify"><B><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> REFERENCIAS&nbsp; </FONT></B> </P>     <!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 1.&nbsp;Ungerstedt U. Microdialysis-principles and applications for studies in  animals and man. J Intern Med 1991; 230: 365-373.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113661&pid=S0535-5133200300030000600001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 2.&nbsp;Hamani C, Luer MS, Dujovny M. Microdi&#225;lisis in the human brain: review  of its applications. Neurol Res 1997; 19: 281-288.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113662&pid=S0535-5133200300030000600002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 3.&nbsp;Nielsen PS, Winge K, Petersen LM. Microdialysis. A method for measurement  of local tissue metabolism. Ugeskr Laeger 1999; 161: 1735-1738.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113663&pid=S0535-5133200300030000600003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 4.&nbsp;Hutchinson PJ, O&#146;conell MT, Kirkpatrick PJ, Pickard JD. How can we measure  substrate, metabolite and neurotransmitter concentrations in the human  brain. Physiol Meas 2002; 23: R75-R109.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113664&pid=S0535-5133200300030000600004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 5.&nbsp;M&#252;ller M. Microdialysis. BMJ 2002; 324: 588-591.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113665&pid=S0535-5133200300030000600005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 6.&nbsp;Westerik BHC.. Brain microdialysis and its application for the study of  animal behavior. Behav Brain Res 1995; 70:103-124.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113666&pid=S0535-5133200300030000600006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 7.&nbsp;Elmquist WF, Sawchuk RJ. Application of microdialysis in pharmacokinetic  studies. Pharm Res 1997; 14:267-288.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113667&pid=S0535-5133200300030000600007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 8.&nbsp;Johansen MJ, Newman RA, Madden T. The use of microdialysis in pharmacokinetics  and pharmacodynamics. Pharmacotherapy 1997; 17:464-481.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113668&pid=S0535-5133200300030000600008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 9.&nbsp;Hollenstein U, Brunner M, Mayer BX, Delacher S, Erovich B, Eichler FG,  Muller M. Target site concentrations after continuous infusion and bolus  injection of cefpirome to healthy volunteers. Clin Pharmacol Ther 2000;  67:229-236.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113669&pid=S0535-5133200300030000600009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 10.&nbsp;P&#225;ez X, Hern&#225;ndez L. Blood microdialysis in humans: a new method for monitoring  plasma compounds. Life Sci&nbsp;1997; 61: 847-856.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113670&pid=S0535-5133200300030000600010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 11.&nbsp;De La Pe&#241;a A, Liu P, Derenndorf H. Microdi&#225;lisis in peripheral tissues.  Adv Drug Deliv Rev 2000; 45:189-216.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113671&pid=S0535-5133200300030000600011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 12.&nbsp;Joukhadar C, Derendorf H, Muller M. Microdi&#225;lisis. A novel tool for clinical  studies of anti-infective agents. Eur Clin Pharmacol 2001; 57: 211-219.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113672&pid=S0535-5133200300030000600012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 13.&nbsp;Goraca A. Minireview: microdi&#225;lisis of the blood outflowing from brain.  Endocr Regul 2001; 35: 229-236.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113673&pid=S0535-5133200300030000600013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 14.&nbsp;Nowak G, Ungerstedt J, Ungerstedt U, Ericzon BG. Clinical experience in  continuous graft monitoring with microdialysis early after liver transplantation.  Br J Surg 2002; 89:1169-1175.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113674&pid=S0535-5133200300030000600014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 15.&nbsp;Dabrosin C, Hallstrom A, Ungerstedst U, Hammar M. Microdialysis of human  breast tissue during the menstrual cycle. Clin Sci 1997; 92:493-496.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113675&pid=S0535-5133200300030000600015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 16.&nbsp;Ederoth P, Flisberg P, Ungerstedt U, Nordstrom CH, Lundberg J. Local metabolic  changes in subcutaneous adipose tissue during intravenous and epidural  analgesia. Acta Anaesthesiol Scand 2002; 46:585-591.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113676&pid=S0535-5133200300030000600016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 17.&nbsp;Minahan RE, Bhardwaj A, Williams MA. Critical care monitoring for cerebrovascular  disease. New Horiz 1997; 5: 406-421.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113677&pid=S0535-5133200300030000600017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 18.&nbsp;Alvarez Del Castillo M. Monitoring neurologic patients in intensive care.  Curr Opin Crit Care 2002; 7:49-60.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113678&pid=S0535-5133200300030000600018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 19.&nbsp;Mendelowitsch A. Microdialysis: intraoperative and posttraumatic applications  in neurosurgery. Methods 2001; 23: 73-81.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113679&pid=S0535-5133200300030000600019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 20.&nbsp;Ronne-Engstrom E, Cesarini KG, Enblad P, Hesslager G, Marklud N, Nilsson  P, Salci K, Persson L, Hillered L. Intracerebral microdialysis in neurointensive  care: the use of urea as an endogenous reference compound. J Neurosurg  2001; 94:397-402.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113680&pid=S0535-5133200300030000600020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 21.&nbsp;Binnert C, Tappy L. Microdialysis in the intensive care unit: a novel tool  for clinical investigation or monitoring? Curr Opin Clin Nutr Metab Care  2002; 5:185-188.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113681&pid=S0535-5133200300030000600021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 22.&nbsp;Stjernstrom H, Carlsson T, Ungerstedt U, Hillered L: Chemical monitoring  of intensive care patients using intravenous microdialysis. Intensive Care  Med 1993;19: 423-428.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113682&pid=S0535-5133200300030000600022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 23.&nbsp;Rabenstein K, Mcshane AJ, Mckenna MJ, Dempsey E, Keaveny TV. An intravenous  microdialysis sampling system suitable for application in continuos monitoring  of glucose and lactate. Technol Health Care 1996; 4:67-76.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113683&pid=S0535-5133200300030000600023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 24.&nbsp;Arner P, Bolinder J. Microdialysis of adipose tissue. J Intern Med 1991;  230: 381-386.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113684&pid=S0535-5133200300030000600024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 25.&nbsp;Simonsen L, Bulow J, Madsen J. Adipose tissue metabolism in humans determined  by vein catheterization and microdialysis techniques. Am J Physiol 1994;  266: E357-E365.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113685&pid=S0535-5133200300030000600025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 26.&nbsp;Hutchinson PJ. O&#146;conell MT, Maskell LB, Pickard JD. Monitoring by subcutaneous  microdialysis in neurosurgical intensive care. Acta Neurochir 1999; 75:  57-59.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113686&pid=S0535-5133200300030000600026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 27.&nbsp;Rojdmark J, Heden P, Ungerstedt U. Prediction of border necrosis in skin  flaps of pigs with microdialysis. J Reconstr Microsurg 2000; 16:129-134.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113687&pid=S0535-5133200300030000600027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 28.&nbsp;Damian MS, Sauter W, Reichmann H. Subcutaneous microdialysis in mitocondrial  cytopathy. Muscle Nerve 2001; 24: 648-653.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113688&pid=S0535-5133200300030000600028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 29.&nbsp;Rolinski B, Baumeister FA, Roscher AA. Determination of amino acid tissue  concentrations by microdialysis: method evaluation and relation to plasma  values. Amino Acids 2001; 21: 129-138.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113689&pid=S0535-5133200300030000600029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 30.&nbsp;Klaus S, Bahlmann L, Gliemroth J, Heringlake M, Prussman M, Schmucker P.  Microdialysis for metabolic monitoring during septicemia. Biomed Tech 2001;  46: 304-306.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113690&pid=S0535-5133200300030000600030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 31.&nbsp;Mathy FX, Preat V, Verbeeck RK. Validation of subcutaneous microdialysis  sampling for pharmacokinetic studies of flurbiprofen in the rat. J Pharm  Sci 2001; 90: 1897-1906.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113691&pid=S0535-5133200300030000600031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 32.&nbsp;Mader RM, Brunnerm, Mensik C, Steger GC, Eichler HG, Muller M. Analysis  of microdialysates from cancer patients by capillary electrophoresis. Electrophoresis  1998; 19: 2981-2985.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113692&pid=S0535-5133200300030000600032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 33.&nbsp;Tegeder I, Schmidtko A, Brautigam L, Kirschbaum A, Geisslinger G, Lotsch  J. Tissue distribution of imipenem in critically ill patients. Clin Pharmacol  Ther 2002; 71: 325-333.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113693&pid=S0535-5133200300030000600033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 34.&nbsp;Robert JJ. Continuous monitoring of glucose. Horm Res 2002; 57:81-84.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113694&pid=S0535-5133200300030000600034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 35.&nbsp;Baumeister FA, Rolinski B, Busch R, Emmrich P. Glucose monitoring with  long-term subcutaneous microdialysis in neonates. Pediatrics 2001; 108:  1187-1192.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113695&pid=S0535-5133200300030000600035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 36.&nbsp;Tiessen RG, Rhemrev-Boom MM, Korf J. Glucose gradient differences in subcutaneous  tissue of healthy volunteers assessed with ultraslow microdialysis and  a nanoliter glucose sensor. Life Sci 2002; 70:2457-2466.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113696&pid=S0535-5133200300030000600036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 37.&nbsp;Kellog DL Jr, Crandall CG, Liu Y, Charkoudian N, Johnson JM. Nitric oxide  and cutaneous active vasodilatation during heat stress in humans. J Appl  Physiol 1998; 85: 824-829.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113697&pid=S0535-5133200300030000600037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 38.&nbsp;Clough GF, Bennett AR, Church MK. Measurement of nitric oxide concentration  in human skin in vivo using dermal microdialysis. Exp Physiol 1998; 83:  431-434.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113698&pid=S0535-5133200300030000600038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 39.&nbsp;Benfeldt E, Groth L. Feasibility of measuring lipophilic or protein-bound  drugs in the dermis by in vivo microdialysis after topical or systemic  drug administration. Acta Derm Venereol 1998; 78:274-278.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113699&pid=S0535-5133200300030000600039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 40.&nbsp;Dawson LA. Capillary electrophoresis and microdi&#225;lisis: current technology  and applications. J Chromatogr B Biomed Sci Appl 1997; 697: 89-99.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113700&pid=S0535-5133200300030000600040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 41.&nbsp;Denoroy L, Bert L, Parrot S, Robert F, Renaud B. Assessment of pharmacodynamic  and pharmacokinetic characteristics of drugs using microdialysis sampling  and capillary electrophoresis. Electrophoresis 1998; 19:2841-2847.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113701&pid=S0535-5133200300030000600041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 42.&nbsp;Moller JG, Stass H, Heing R, Blaschke G. Capillary electrophoresis with  laser-induced fluorescence: a routine method to determine moxifloxacin  in human body fluids in very small sample volumes. J Chromatogr B Biomed  Sci Appl 1998; 716: 325-334.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113702&pid=S0535-5133200300030000600042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 43.&nbsp;P&#225;ez X, Hern&#225;ndez L. Biomedical applications of capillary electrophoresis  with laser-induced fuorescence detection. Biopharm Drug Dispos. 2001; 22:  273-289.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113703&pid=S0535-5133200300030000600043&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 44.&nbsp;Tucci S, Rada P, Sep&#250;lveda MJ, Hern&#225;ndez L. Glutamate measured by 6.s resolution  brain microdialysis: capillary electrophoresis and laser-induced fluorescence  detection application. J Chromatog B Biomed Sci Appl 1997; 694:343-349.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113704&pid=S0535-5133200300030000600044&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 45.&nbsp;P&#225;ez X, Rada P, Hern&#225;ndez L. Neutral amino acids monitoring in phenylketonuric  plasma microdialysates using micellar electrokinetic chromatography and  laser-induced fluorescence detection. J Chromatogr B 2000; 739:247-254.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113705&pid=S0535-5133200300030000600045&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 46.&nbsp;Rada P, Tucci S, Teneud L, P&#225;ez X, P&#233;rez J, Alba G, Garcia I, Sacchettoni  S, Del Corral J, Hern&#225;ndez L. Monitoring gamma-aminobutyric acid (GABA)  in human brain and plasma microdialysates using micellar electrokinetic  chromatography and laser-induced fluorescence detection. J Chromatogr B  1999; 735: 1-10.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113706&pid=S0535-5133200300030000600046&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 47.&nbsp;Hern&#225;ndez L, Tucci S, P&#225;ez X, Guzm&#225;n N. In vivo monitoring of glutamate  in the brain by dialysis and capillary electrophoresis with laser-induced  fluorescence detection. J Liq Chromatogr 1993; 652: 393-398.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113707&pid=S0535-5133200300030000600047&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 48.&nbsp;Kamel A, Norgren S, Person B, Marcus C. Insulin induced hypoglycaemia:  comparison of glucose and glycerol concentrations in plasma and microdi&#225;lisis  from subcutaneous adipose tissue. Arch Dis Child 1999; 42-45.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113708&pid=S0535-5133200300030000600048&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 49.&nbsp;Wientjes KJ, Schoonen AJ. Determination of time delay between blood and  interstitial adipose tissue glucose concentration change by microdialysis  in healthy volunteers. Int J Artif Organs 2001; 24:884-889.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113709&pid=S0535-5133200300030000600049&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 50.&nbsp;Castej&#243;n AM, P&#225;ez X, Hern&#225;ndez L, Cubeddu L. Use of intravenous microdialysis  to monitor changes in serotonina release and metabolism induced by cisplatin  in cancer patients: comparative effects of granisetron and ondasetron.  J Phar Exp Ther 1999; 291:960-966.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113710&pid=S0535-5133200300030000600050&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 51.&nbsp;Tolias CM, Richards DA, Bowery NG, Sgouros S. Extracellular glutamate in  the brains of children with severe head injuries: a pilot microdialysis  study. Child Nerv Syst 2002; 18: 368-374.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113711&pid=S0535-5133200300030000600051&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 52.&nbsp;Obrenovitch TP, Zilkha E. Microdialysis coupled to online enzymatic assays.  Methods 2001; 23: 63-71.&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113712&pid=S0535-5133200300030000600052&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P align="justify"><FONT COLOR="#1f1a17" size="3" face="Times New Roman"> 53.&nbsp;Davies MI, Cooper JD, Desmond SS, Lunte CE, Lunte SM. Analytical considerations  for microdialysis sampling. Adv Drug Deliv Rev 2000; 45:169-188&nbsp;</FONT>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1113713&pid=S0535-5133200300030000600053&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body>
<back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ungerstedt]]></surname>
<given-names><![CDATA[U.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microdialysis-principles and applications for studies in animals and man]]></article-title>
<source><![CDATA[J Intern Med]]></source>
<year>1991</year>
<volume>230</volume>
<page-range>365-373</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hamani]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Luer]]></surname>
<given-names><![CDATA[MS]]></given-names>
</name>
<name>
<surname><![CDATA[Dujovny]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microdiálisis in the human brain: review of its applications]]></article-title>
<source><![CDATA[Neurol Res]]></source>
<year>1997</year>
<volume>19</volume>
<page-range>281-288</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nielsen]]></surname>
<given-names><![CDATA[PS]]></given-names>
</name>
<name>
<surname><![CDATA[Winge]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Petersen]]></surname>
<given-names><![CDATA[LM.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microdialysis: A method for measurement of local tissue metabolism]]></article-title>
<source><![CDATA[Ugeskr Laeger]]></source>
<year>1999</year>
<volume>161</volume>
<page-range>1735-1738</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hutchinson]]></surname>
<given-names><![CDATA[PJ]]></given-names>
</name>
<name>
<surname><![CDATA[O’conell]]></surname>
<given-names><![CDATA[MT]]></given-names>
</name>
<name>
<surname><![CDATA[Kirkpatrick]]></surname>
<given-names><![CDATA[PJ]]></given-names>
</name>
<name>
<surname><![CDATA[Pickard]]></surname>
<given-names><![CDATA[JD.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[How can we measure substrate, metabolite and neurotransmitter concentrations in the human brain]]></article-title>
<source><![CDATA[Physiol Meas]]></source>
<year>2002</year>
<volume>23</volume>
<page-range>R75-R109</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Müller]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microdialysis]]></article-title>
<source><![CDATA[BMJ]]></source>
<year>2002</year>
<volume>324</volume>
<page-range>588-591</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Westerik]]></surname>
<given-names><![CDATA[BHC.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Brain microdialysis and its application for the study of animal behavior]]></article-title>
<source><![CDATA[Behav Brain Res]]></source>
<year>1995</year>
<volume>70</volume>
<page-range>103-124</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Elmquist]]></surname>
<given-names><![CDATA[WF]]></given-names>
</name>
<name>
<surname><![CDATA[Sawchuk]]></surname>
<given-names><![CDATA[RJ.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Application of microdialysis in pharmacokinetic studies]]></article-title>
<source><![CDATA[Pharm Res]]></source>
<year>1997</year>
<volume>14</volume>
<page-range>267-288</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Johansen]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Newman]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
<name>
<surname><![CDATA[Madden]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The use of microdialysis in pharmacokinetics and pharmacodynamics]]></article-title>
<source><![CDATA[Pharmacotherapy]]></source>
<year>1997</year>
<volume>17</volume>
<page-range>464-481</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hollenstein]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Brunner]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Mayer]]></surname>
<given-names><![CDATA[BX]]></given-names>
</name>
<name>
<surname><![CDATA[Delacher]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Erovich]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Eichler]]></surname>
<given-names><![CDATA[FG]]></given-names>
</name>
<name>
<surname><![CDATA[Muller]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Target site concentrations after continuous infusion and bolus injection of cefpirome to healthy volunteers]]></article-title>
<source><![CDATA[Clin Pharmacol Ther]]></source>
<year>2000</year>
<volume>67</volume>
<page-range>229-236</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Páez]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Blood microdialysis in humans: a new method for monitoring plasma compounds]]></article-title>
<source><![CDATA[Life Sci]]></source>
<year>1997</year>
<volume>61</volume>
<page-range>847-856</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De La Peña]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Derenndorf]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microdiálisis in peripheral tissues]]></article-title>
<source><![CDATA[Adv Drug Deliv Rev]]></source>
<year>2000</year>
<volume>45</volume>
<page-range>189-216</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Joukhadar]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Derendorf]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Muller]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microdiálisis: A novel tool for clinical studies of anti-infective agents]]></article-title>
<source><![CDATA[Eur Clin Pharmacol]]></source>
<year>2001</year>
<volume>57</volume>
<page-range>211-219</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Goraca]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Minireview: microdiálisis of the blood outflowing from brain]]></article-title>
<source><![CDATA[Endocr Regul]]></source>
<year>2001</year>
<volume>35</volume>
<page-range>229-236</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nowak]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Ungerstedt]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Ungerstedt]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Ericzon]]></surname>
<given-names><![CDATA[BG.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical experience in continuous graft monitoring with microdialysis early after liver transplantation]]></article-title>
<source><![CDATA[Br J Surg]]></source>
<year>2002</year>
<volume>89</volume>
<page-range>1169-1175</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dabrosin]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Hallstrom]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Ungerstedst]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Hammar]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microdialysis of human breast tissue during the menstrual cycle]]></article-title>
<source><![CDATA[Clin Sci]]></source>
<year>1997</year>
<volume>92</volume>
<page-range>493-496</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ederoth]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Flisberg]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Ungerstedt]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Nordstrom]]></surname>
<given-names><![CDATA[CH]]></given-names>
</name>
<name>
<surname><![CDATA[Lundberg]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Local metabolic changes in subcutaneous adipose tissue during intravenous and epidural analgesia]]></article-title>
<source><![CDATA[Acta Anaesthesiol Scand]]></source>
<year>2002</year>
<volume>46</volume>
<page-range>585-591</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Minahan]]></surname>
<given-names><![CDATA[RE]]></given-names>
</name>
<name>
<surname><![CDATA[Bhardwaj]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Williams]]></surname>
<given-names><![CDATA[MA.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Critical care monitoring for cerebrovascular disease]]></article-title>
<source><![CDATA[New Horiz]]></source>
<year>1997</year>
<volume>5</volume>
<page-range>406-421</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Alvarez Del Castillo]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Monitoring neurologic patients in intensive care]]></article-title>
<source><![CDATA[Curr Opin Crit Care]]></source>
<year>2002</year>
<volume>7</volume>
<page-range>49-60</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mendelowitsch]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microdialysis: intraoperative and posttraumatic applications in neurosurgery]]></article-title>
<source><![CDATA[Methods]]></source>
<year>2001</year>
<volume>23</volume>
<page-range>73-81</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ronne-Engstrom]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Cesarini]]></surname>
<given-names><![CDATA[KG]]></given-names>
</name>
<name>
<surname><![CDATA[Enblad]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Hesslager]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Marklud]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Nilsson]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Salci]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Persson]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Hillered]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intracerebral microdialysis in neurointensive care: the use of urea as an endogenous reference compound]]></article-title>
<source><![CDATA[J Neurosurg]]></source>
<year>2001</year>
<volume>94</volume>
<page-range>397-402</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Binnert]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Tappy]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microdialysis in the intensive care unit: a novel tool for clinical investigation or monitoring?]]></article-title>
<source><![CDATA[Curr Opin Clin Nutr Metab Care]]></source>
<year>2002</year>
<volume>5</volume>
<page-range>185-188</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stjernstrom]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Carlsson]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Ungerstedt]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Hillered]]></surname>
<given-names><![CDATA[L:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Chemical monitoring of intensive care patients using intravenous microdialysis]]></article-title>
<source><![CDATA[Intensive Care Med]]></source>
<year>1993</year>
<volume>19</volume>
<page-range>423-428</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rabenstein]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Mcshane]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Mckenna]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Dempsey]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Keaveny]]></surname>
<given-names><![CDATA[TV.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An intravenous microdialysis sampling system suitable for application in continuos monitoring of glucose and lactate]]></article-title>
<source><![CDATA[Technol Health Care]]></source>
<year>1996</year>
<volume>4</volume>
<page-range>67-76</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Arner]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Bolinder]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microdialysis of adipose tissue]]></article-title>
<source><![CDATA[J Intern Med]]></source>
<year>1991</year>
<volume>230</volume>
<page-range>381-386</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Simonsen]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Bulow]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Madsen]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Adipose tissue metabolism in humans determined by vein catheterization and microdialysis techniques]]></article-title>
<source><![CDATA[Am J Physiol]]></source>
<year>1994</year>
<volume>266</volume>
<page-range>E357-E365</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hutchinson]]></surname>
<given-names><![CDATA[PJ.]]></given-names>
</name>
<name>
<surname><![CDATA[O’conell]]></surname>
<given-names><![CDATA[MT]]></given-names>
</name>
<name>
<surname><![CDATA[Maskell]]></surname>
<given-names><![CDATA[LB]]></given-names>
</name>
<name>
<surname><![CDATA[Pickard]]></surname>
<given-names><![CDATA[JD.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Monitoring by subcutaneous microdialysis in neurosurgical intensive care]]></article-title>
<source><![CDATA[Acta Neurochir]]></source>
<year>1999</year>
<month>57</month>
<day>-5</day>
<volume>75</volume>
</nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rojdmark]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Heden]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Ungerstedt]]></surname>
<given-names><![CDATA[U.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prediction of border necrosis in skin flaps of pigs with microdialysis]]></article-title>
<source><![CDATA[J Reconstr Microsurg]]></source>
<year>2000</year>
<volume>16</volume>
<page-range>129-134</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Damian]]></surname>
<given-names><![CDATA[MS]]></given-names>
</name>
<name>
<surname><![CDATA[Sauter]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Reichmann]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Subcutaneous microdialysis in mitocondrial cytopathy]]></article-title>
<source><![CDATA[Muscle Nerve]]></source>
<year>2001</year>
<volume>24</volume>
<page-range>648-653</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rolinski]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Baumeister]]></surname>
<given-names><![CDATA[FA]]></given-names>
</name>
<name>
<surname><![CDATA[Roscher]]></surname>
<given-names><![CDATA[AA.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Determination of amino acid tissue concentrations by microdialysis: method evaluation and relation to plasma values]]></article-title>
<source><![CDATA[Amino Acids]]></source>
<year>2001</year>
<volume>21</volume>
<page-range>129-138</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Klaus]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bahlmann]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Gliemroth]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Heringlake]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Prussman]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Schmucker]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microdialysis for metabolic monitoring during septicemia]]></article-title>
<source><![CDATA[Biomed Tech]]></source>
<year>2001</year>
<volume>46</volume>
<page-range>304-306</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mathy]]></surname>
<given-names><![CDATA[FX]]></given-names>
</name>
<name>
<surname><![CDATA[Preat]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Verbeeck]]></surname>
<given-names><![CDATA[RK.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Validation of subcutaneous microdialysis sampling for pharmacokinetic studies of flurbiprofen in the rat]]></article-title>
<source><![CDATA[J Pharm Sci]]></source>
<year>2001</year>
<volume>90</volume>
<page-range>1897-1906</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mader]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
<name>
<surname><![CDATA[Brunnerm]]></surname>
</name>
<name>
<surname><![CDATA[Mensik]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Steger]]></surname>
<given-names><![CDATA[GC]]></given-names>
</name>
<name>
<surname><![CDATA[Eichler]]></surname>
<given-names><![CDATA[HG]]></given-names>
</name>
<name>
<surname><![CDATA[Muller]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Analysis of microdialysates from cancer patients by capillary electrophoresis]]></article-title>
<source><![CDATA[Electrophoresis]]></source>
<year>1998</year>
<volume>19</volume>
<page-range>2981-2985</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tegeder]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Schmidtko]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Brautigam]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Kirschbaum]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Geisslinger]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Lotsch]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Tissue distribution of imipenem in critically ill patients]]></article-title>
<source><![CDATA[Clin Pharmacol Ther]]></source>
<year>2002</year>
<volume>71</volume>
<page-range>325-333</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Robert]]></surname>
<given-names><![CDATA[JJ.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Continuous monitoring of glucose]]></article-title>
<source><![CDATA[Horm Res]]></source>
<year>2002</year>
<volume>57</volume>
<page-range>81-84</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baumeister]]></surname>
<given-names><![CDATA[FA]]></given-names>
</name>
<name>
<surname><![CDATA[Rolinski]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Busch]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Emmrich]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Glucose monitoring with long-term subcutaneous microdialysis in neonates]]></article-title>
<source><![CDATA[Pediatrics]]></source>
<year>2001</year>
<volume>108</volume>
<page-range>1187-1192</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tiessen]]></surname>
<given-names><![CDATA[RG]]></given-names>
</name>
<name>
<surname><![CDATA[Rhemrev-Boom]]></surname>
<given-names><![CDATA[MM]]></given-names>
</name>
<name>
<surname><![CDATA[Korf]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Glucose gradient differences in subcutaneous tissue of healthy volunteers assessed with ultraslow microdialysis and a nanoliter glucose sensor]]></article-title>
<source><![CDATA[Life Sci]]></source>
<year>2002</year>
<volume>70</volume>
<page-range>2457-2466</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kellog]]></surname>
<given-names><![CDATA[DL Jr]]></given-names>
</name>
<name>
<surname><![CDATA[Crandall]]></surname>
<given-names><![CDATA[CG]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Charkoudian]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Johnson]]></surname>
<given-names><![CDATA[JM.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Nitric oxide and cutaneous active vasodilatation during heat stress in humans]]></article-title>
<source><![CDATA[J Appl Physiol]]></source>
<year>1998</year>
<volume>85</volume>
<page-range>824-829</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Clough]]></surname>
<given-names><![CDATA[GF]]></given-names>
</name>
<name>
<surname><![CDATA[Bennett]]></surname>
<given-names><![CDATA[AR]]></given-names>
</name>
<name>
<surname><![CDATA[Church]]></surname>
<given-names><![CDATA[MK.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Measurement of nitric oxide concentration in human skin in vivo using dermal microdialysis]]></article-title>
<source><![CDATA[Exp Physiol]]></source>
<year>1998</year>
<volume>83</volume>
<page-range>431-434</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Benfeldt]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Groth]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Feasibility of measuring lipophilic or protein-bound drugs in the dermis by in vivo microdialysis after topical or systemic drug administration]]></article-title>
<source><![CDATA[Acta Derm Venereol]]></source>
<year>1998</year>
<volume>78</volume>
<page-range>274-278</page-range></nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dawson]]></surname>
<given-names><![CDATA[LA.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Capillary electrophoresis and microdiálisis: current technology and applications]]></article-title>
<source><![CDATA[J Chromatogr B Biomed Sci Appl]]></source>
<year>1997</year>
<volume>697</volume>
<page-range>89-99</page-range></nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Denoroy]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Bert]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Parrot]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Robert]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Renaud]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Assessment of pharmacodynamic and pharmacokinetic characteristics of drugs using microdialysis sampling and capillary electrophoresis]]></article-title>
<source><![CDATA[Electrophoresis]]></source>
<year>1998</year>
<volume>19</volume>
<page-range>2841-2847</page-range></nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moller]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
<name>
<surname><![CDATA[Stass]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Heing]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Blaschke]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Capillary electrophoresis with laser-induced fluorescence: a routine method to determine moxifloxacin in human body fluids in very small sample volumes]]></article-title>
<source><![CDATA[J Chromatogr B Biomed Sci Appl]]></source>
<year>1998</year>
<volume>716</volume>
<page-range>325-334</page-range></nlm-citation>
</ref>
<ref id="B43">
<label>43</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Páez]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biomedical applications of capillary electrophoresis with laser-induced fuorescence detection]]></article-title>
<source><![CDATA[Biopharm Drug Dispos.]]></source>
<year>2001</year>
<volume>22</volume>
<page-range>273-289</page-range></nlm-citation>
</ref>
<ref id="B44">
<label>44</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tucci]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Rada]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Sepúlveda]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Glutamate measured by 6.s resolution brain microdialysis: capillary electrophoresis and laser-induced fluorescence detection application]]></article-title>
<source><![CDATA[J Chromatog B Biomed Sci Appl]]></source>
<year>1997</year>
<volume>694</volume>
<page-range>343-349</page-range></nlm-citation>
</ref>
<ref id="B45">
<label>45</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Páez]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Rada]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Neutral amino acids monitoring in phenylketonuric plasma microdialysates using micellar electrokinetic chromatography and laser-induced fluorescence detection]]></article-title>
<source><![CDATA[J Chromatogr B]]></source>
<year>2000</year>
<volume>739</volume>
<page-range>247-254</page-range></nlm-citation>
</ref>
<ref id="B46">
<label>46</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rada]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Tucci]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Teneud]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Páez]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Alba]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Garcia]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Sacchettoni]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Del Corral]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Monitoring gamma-aminobutyric acid (GABA) in human brain and plasma microdialysates using micellar electrokinetic chromatography and laser-induced fluorescence detection]]></article-title>
<source><![CDATA[J Chromatogr B]]></source>
<year>1999</year>
<volume>735</volume>
<page-range>1-10</page-range></nlm-citation>
</ref>
<ref id="B47">
<label>47</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Tucci]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Páez]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Guzmán]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vivo monitoring of glutamate in the brain by dialysis and capillary electrophoresis with laser-induced fluorescence detection]]></article-title>
<source><![CDATA[J Liq Chromatogr]]></source>
<year>1993</year>
<volume>652</volume>
<page-range>393-398</page-range></nlm-citation>
</ref>
<ref id="B48">
<label>48</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kamel]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Norgren]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Person]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Marcus]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Insulin induced hypoglycaemia: comparison of glucose and glycerol concentrations in plasma and microdiálisis from subcutaneous adipose tissue]]></article-title>
<source><![CDATA[Arch Dis Child]]></source>
<year>1999</year>
<page-range>42-45</page-range></nlm-citation>
</ref>
<ref id="B49">
<label>49</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wientjes]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
<name>
<surname><![CDATA[Schoonen]]></surname>
<given-names><![CDATA[AJ.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Determination of time delay between blood and interstitial adipose tissue glucose concentration change by microdialysis in healthy volunteers]]></article-title>
<source><![CDATA[Int J Artif Organs]]></source>
<year>2001</year>
<volume>24</volume>
<page-range>884-889</page-range></nlm-citation>
</ref>
<ref id="B50">
<label>50</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Castejón]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Páez]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Cubeddu]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Use of intravenous microdialysis to monitor changes in serotonina release and metabolism induced by cisplatin in cancer patients: comparative effects of granisetron and ondasetron]]></article-title>
<source><![CDATA[J Phar Exp Ther]]></source>
<year>1999</year>
<volume>291</volume>
<page-range>960-966</page-range></nlm-citation>
</ref>
<ref id="B51">
<label>51</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tolias]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
<name>
<surname><![CDATA[Richards]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Bowery]]></surname>
<given-names><![CDATA[NG]]></given-names>
</name>
<name>
<surname><![CDATA[Sgouros]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Extracellular glutamate in the brains of children with severe head injuries: a pilot microdialysis study]]></article-title>
<source><![CDATA[Child Nerv Syst]]></source>
<year>2002</year>
<volume>18</volume>
<page-range>368-374</page-range></nlm-citation>
</ref>
<ref id="B52">
<label>52</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Obrenovitch]]></surname>
<given-names><![CDATA[TP]]></given-names>
</name>
<name>
<surname><![CDATA[Zilkha]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microdialysis coupled to online enzymatic assays]]></article-title>
<source><![CDATA[Methods]]></source>
<year>2001</year>
<volume>23</volume>
<page-range>63-71</page-range></nlm-citation>
</ref>
<ref id="B53">
<label>53</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Davies]]></surname>
<given-names><![CDATA[MI]]></given-names>
</name>
<name>
<surname><![CDATA[Cooper]]></surname>
<given-names><![CDATA[JD]]></given-names>
</name>
<name>
<surname><![CDATA[Desmond]]></surname>
<given-names><![CDATA[SS]]></given-names>
</name>
<name>
<surname><![CDATA[Lunte]]></surname>
<given-names><![CDATA[CE]]></given-names>
</name>
<name>
<surname><![CDATA[Lunte]]></surname>
<given-names><![CDATA[SM.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Analytical considerations for microdialysis sampling]]></article-title>
<source><![CDATA[Adv Drug Deliv Rev]]></source>
<year>2000</year>
<volume>45</volume>
<page-range>169-188</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
