<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0798-4065</journal-id>
<journal-title><![CDATA[Revista de la Facultad de Ingeniería Universidad Central de Venezuela]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Fac. Ing. UCV]]></abbrev-journal-title>
<issn>0798-4065</issn>
<publisher>
<publisher-name><![CDATA[Universidad Central de Venezuela]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0798-40652012000400009</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Design and construction of a 57Fe Mössbauer spectrometer for studies in surface physics]]></article-title>
<article-title xml:lang="es"><![CDATA[DISEÑO Y CONSTRUCCIÓN DE UN ESPECTRÓMETRO MÖSSBAUER DE 57Fe PARA ESTUDIOS EN FÍSICA DE SUPERFICIES]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Moutinho]]></surname>
<given-names><![CDATA[Fernando]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rojas]]></surname>
<given-names><![CDATA[Carlos]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[D’onofrio]]></surname>
<given-names><![CDATA[Lisseta]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rojas]]></surname>
<given-names><![CDATA[Humberto]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Central de Venezuela Facultad de Ciencias Centro de Física Experimental del Sólido]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2012</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2012</year>
</pub-date>
<volume>27</volume>
<numero>4</numero>
<fpage>75</fpage>
<lpage>82</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_arttext&amp;pid=S0798-40652012000400009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_abstract&amp;pid=S0798-40652012000400009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_pdf&amp;pid=S0798-40652012000400009&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[In this work we describe the design and construction of a Mössbauer spectrometer based in the use of a Channel Electron Multiplier to detect the electrons emitted as a consequence of the resonant nuclear absorption of &#947;-Rays by 57Fe containing samples. The main resonant signals being detected are the Fe(K), Fe(L) and Fe(M) conversion electrons as well as the Fe(KLM), Fe(KLL) and Fe(LMM) Auger electrons. The design is compact since all the components of the spectrometer are mounted into a single flange, so it can be easily installed in any conventional vacuum chamber dedicated to the study of surfaces. Its performance was tested by acquiring Mössbauer spectra from a pure iron metal sheet and from an iron metal thin film deposited onto a stainless steel plate]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[En el presente trabajo se describe el diseño y construcción de un espectrómetro Mössbauer basado en el uso de un multiplicador de electrones tipo canal para detectar los electrones emitidos como consecuencia de la absorción resonante de Rayos &#947; por muestras que contengan el isótopo 57Fe. Las principales señales resonantes que se detectan son las de electrones de conversión Fe(K), Fe(L) y Fe(M), así como las de electrones Auger Fe(KLM), Fe(KLL) y Fe(LMM). El diseño es compacto ya que todos los componentes del espectrómetro están montados en una sola brida, la cual puede ser fácilmente instalada en cualquier cámara de vacío convencional dedicada al estudio de superficies. Se probó su desempeño mediante la adquisición de espectros Mössbauer de una lámina de hierro metálico puro y de una película delgada de hierro metálico depositada sobre una placa de acero inoxidable]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[Mössbauer-Spectroscopy]]></kwd>
<kwd lng="en"><![CDATA[Surfaces]]></kwd>
<kwd lng="en"><![CDATA[CEMS]]></kwd>
<kwd lng="en"><![CDATA[ICEMS]]></kwd>
<kwd lng="en"><![CDATA[Channel-electron-multiplier]]></kwd>
<kwd lng="es"><![CDATA[Espectroscopía Mössbauer]]></kwd>
<kwd lng="es"><![CDATA[Superficies]]></kwd>
<kwd lng="es"><![CDATA[CEMS]]></kwd>
<kwd lng="es"><![CDATA[ICEMS]]></kwd>
<kwd lng="es"><![CDATA[Multiplicador de electrones]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p ALIGN="justify"></p> <font FACE="Verdana">     <p align="center"><i><span style="font-family: Verdana">&nbsp;</span></i><b><span lang="EN-US" style="font-family: Verdana">Design  and construction of a <sup>57</sup>Fe Mössbauer spectrometer for studies in  surface physics </span></b></p> </font><font FACE="Verdana" SIZE="2">     <p align="center"> <span style="font-size: 10.0pt; font-family: Verdana; font-weight: 700">Fernando  Moutinho, Carlos Rojas, Lisseta D’onofrio And Humberto Rojas </span></p>     <p ALIGN="justify">Centro de Física Experimental del Sólido, Facultad de  Ciencias, Universidad Central de Venezuela&nbsp; e-mail: <a href="mailto:carlosrojas1@gmail.com">carlosrojas1@gmail.com</a>&nbsp; </p> <b>     <p ALIGN="justify">ABSTRACT </p> </b>     <p ALIGN="JUSTIFY">In this work we describe the design and construction of a  Mössbauer spectrometer based in the use of a Channel Electron Multiplier to  detect the electrons emitted as a consequence of the resonant nuclear absorption  of </font><font FACE="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font><font FACE="Verdana" SIZE="2">-Rays  by <sup>57</sup>Fe containing samples. The main resonant signals being detected  are the Fe(K), Fe(L) and Fe(M) conversion electrons as well as the Fe(KLM),  Fe(KLL) and Fe(LMM) Auger electrons. The design is compact since all the  components of the spectrometer are mounted into a single flange, so it can be  easily installed in any conventional vacuum chamber dedicated to the study of  surfaces. Its performance was tested by acquiring Mössbauer spectra from a pure  iron metal sheet and from an iron metal thin film deposited onto a stainless  steel plate. </p> <i>     <p ALIGN="JUSTIFY"><b>Keywords: </b></i>Mössbauer-Spectroscopy, Surfaces, CEMS,  ICEMS, Channel-electron-multiplier. </p> </font><b>     <p class="MsoNormal" align="center"> <span style="font-size:10.0pt;font-family:Verdana">Diseño y construcción de un  espectrómetro mössbauer de <sup>57</sup>fe para estudios en física de  superficies</span></p> <font SIZE="2" face="Verdana">     <p ALIGN="justify">RESUMEN </p> </font></b><font FACE="Verdana" SIZE="2">     <p ALIGN="JUSTIFY">En el presente trabajo se describe el diseño y construcción  de un espectrómetro Mössbauer basado en el uso de un multiplicador de electrones  tipo canal para detectar los electrones emitidos como consecuencia de la  absorción resonante de Rayos </font><font FACE="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font><font FACE="Verdana" SIZE="2">  por muestras que contengan el isótopo <sup>57</sup>Fe. Las principales señales  resonantes que se detectan son las de electrones de conversión Fe(K), Fe(L) y  Fe(M), así como las de electrones Auger Fe(KLM), Fe(KLL) y Fe(LMM). El diseño es  compacto ya que todos los componentes del espectrómetro están montados en una  sola brida, la cual puede ser fácilmente instalada en cualquier cámara de vacío  convencional dedicada al estudio de superficies. Se probó su desempeño mediante  la adquisición de espectros Mössbauer de una lámina de hierro metálico puro y de  una película delgada de hierro metálico depositada sobre una placa de acero  inoxidable. </p> <i>     ]]></body>
<body><![CDATA[<p ALIGN="JUSTIFY"><b>Palabras clave:</b> </i>Espectroscopía Mössbauer,  Superficies, CEMS, ICEMS, Multiplicador de electrones.</p>     <p ALIGN="JUSTIFY"><b>Recibido: </b>junio 2010&nbsp; <b>Revisado:</b> agosto  2012</p> <b>     <p ALIGN="JUSTIFY">INTRODUCTION </p> </b>     <p ALIGN="JUSTIFY">Mössbauer Spectroscopy is a well established nuclear  analytical technique based on the Mössbauer effect (Ovchinnikov, 2006),  characterized by its extremely high energy resolution in comparison with atomic  spectroscopies. It is used in the characterization of solids containing the so  called &quot;Mössbauer isotopes&quot;, like <sup>57</sup>Fe, <sup>119</sup>Sn and <sup>151</sup>Eu.  Mössbauer Spectroscopy of the iron isotope <sup>57</sup>Fe is by large the most  widely used because of the relatively high natural abundance of this isotope  (2%), the possibility of working over a wide range of temperatures (~2K-1000K)  and the great importance of iron as a chemical component in samples studied in  fields as diverse as Geology, Metallurgy, Magnetism, Biology and Archeology (Desimoni  et al. 2009). </p>     <p align="justify">The Mössbauer effect consists in the emission of  characteristic <font FACE="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font>-Rays  photons by nuclei of a given species (source) and its resonant absorption by  nuclei of the same species (absorber). Given the small width of the nuclear  levels, for this resonant absorption to occur it is necessary that the nuclei do  not recoil neither in the emission nor in the absorption processes, conditions  that are achieved if they are bound to the structure of a solid state substance.  In<sup> 57</sup>Fe Mössbauer Spectroscopy the source typically consists of  radioactive <sup>57</sup>Co nuclei embedded into a Rh or Pd matrix and the  absorber is the iron containing solid under study. The <sup>57</sup>Co nuclei  decay by electron capture into excited<sup> 57</sup>Fe* nuclei that have a half  life of 270 days. Upon de-excitation, these <sup>57</sup>Fe* nuclei emit  characteristic <font FACE="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font>-Rays  with well defined energies E<sub>1</sub> = 122.0 keV, E<sub>2 </sub>= 136.4 keV  and E<sub>3</sub> = </font><font face="Verdana" SIZE="2">14.4 keV. The <span style="font-family: Times New Roman; color: black">&#947;</span>-Ray photons of  energy E</font><font SIZE="2" face="Verdana"><sub>3</sub> are the ones used in <sup>57</sup></font><font SIZE="2"><font face="Verdana">Fe Mössbauer  Spectroscopy. They are produced when the excited nuclei suffer transitions from  the first excited state (I = 3/2) to the ground state (I = 1/2). </font></p>     <p ALIGN="JUSTIFY"><font face="Verdana">The interaction of the </font></font> <font SIZE="2" face="Verdana"><sup>57</sup>Fe nuclei with the surrounding atoms  in the particular sample under study can cause level shifts and/or splits that  impede the resonant absorption of the 14.4 keV </font><font FACE="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font><font SIZE="2" face="Verdana">-Rays  emitted by the source. However, the resonance condition can be recovered if the  energy of the emitted </font><font FACE="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font><font SIZE="2" face="Verdana">-Rays  is modulated by Doppler effect. This can be done by mounting the source on an  oscillatory mechanical device or velocity transducer which moves the source to  and fro with constant acceleration up to a maximum speed vM in each sense. In  this way the energy of the </font><font FACE="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font><font SIZE="2" face="Verdana">-Rays  is modulated continuously within the interval E<sub>3</sub>(1 ± v<sub>M</sub></font><font SIZE="2"><font face="Verdana">/c)  and the resonant absorption is obtained when the photon energy coincides with an  allowed transition between two nuclear levels in the absorber. In each motion  cycle the condition for a given resonant absorption is achieved twice; one when  the source moves forward and the other when it moves backward. </font></p>     <p ALIGN="JUSTIFY"><font face="Verdana">Conventional Mössbauer Spectroscopy  deals with <span style="font-family: Times New Roman; color: black">&#947;</span>-Rays  absorption spectra, but one can also obtain Mössbauer emission spectra if one  detects the <span style="font-family: Times New Roman; color: black">&#947;</span>-Rays,  the X-rays or the electrons emitted from the sample as a consequence of the de-excitation  of the </font></font><font SIZE="2" face="Verdana">57</font><font SIZE="2"><font face="Verdana">Fe  nuclei which have been excited by the resonant absorption. In the present work  we describe the installation of an electron emission Mössbauer spectrometer in  an ultra-high vacuum (UHV) chamber used for analysis of surfaces with  conventional surface sensitive techniques. </font></p> </font><font FACE="Verdana" SIZE="2"><b>     <p ALIGN="JUSTIFY">THE EMISSION SPECTROMETER </p> </b></font><font SIZE="2">     <p ALIGN="JUSTIFY"><font face="Verdana">It is useful to compare the performance  of the Mössbauer Emission Spectrometer with that of a conventional Mössbauer  Absorption Spectrometer. The absorption detection system used in conventional  spectrometers consists of a simple transmission arrangement composed of the  velocity transducer holding the <span style="font-family: Times New Roman; color: black">&#947;</span>-Ray source,  followed by the absorber and then by a proportional counter. Absorption  Mössbauer spectra are obtained by plotting the intensity of the transmitted </font></font><font face="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span><font SIZE="2">-Ray  signal as a function of the relative velocity between source and absorber. The  spectra show an absorption baseline caused mainly by photoelectric effect in all  types of atoms present in the sample region traversed by the </font> <span style="font-family: Times New Roman; color: black">&#947;</span><font SIZE="2">-Rays,  superimposed on which there are Mössbauer absorption resonances due only to the  presence of </font></font><font SIZE="2" face="Verdana"><sup>57</sup>Fe isotopes.  The statistical quality of the spectra depends mainly on the activity of the  source, on the acquisition time used and on the ratio of <sup>57</sup>Fe  isotopic mass to the total mass of the absorber. The absorption structure  observed in the spectra corresponds to the interaction of the absorbing nuclei  with the surrounding atoms, structure that is evaluated by the so called &quot;hyperfine  parameters&quot; IS, QS and H. The isomer shift (IS) measures the electrostatic  interaction between the absorbent nucleus and the surrounding electrons; it is  characterized by a shift of the spectrum relative to that of a reference  material, usually &#945;-iron. The quadrupole splitting (QS) arises from the  interaction of the nuclear quadrupole moment with the local electric field  gradient. When an asymmetry in the electric charge distribution around the 57</font><font SIZE="2"><font face="Verdana">Fe  nuclei produces an electric field gradient, this interaction causes a splitting  of the I=3/2 nuclear state into two levels, resulting in two distinct spectral  lines. The hyperfine magnetic field (H) measures the splitting caused by the  interaction of the nuclear magnetic moment with the local magnetic field at the  nucleus site. When this internal magnetic field is present, this interaction  lifts all degeneracy between nuclear levels allowing six spectral lines to be  observed. Through a fitting procedure of the experimental data one obtains the  hyperfine parameters which are characteristic of the particular iron phase under  study. For </font></font> <span style="font-family: Times New Roman; color: black">&#945;</span><font SIZE="2"><font face="Verdana">-iron  the Mössbauer spectrum is a sextet with the following values of hyperfine  parameters: IS=0 mm/s, QS=0 mm/s and H=330 kOe. </font></p>     <p align="justify"><font face="Verdana">Once the Mössbauer resonant absorption  has occurred, the excited </font></font><font SIZE="2" face="Verdana"><sup>57</sup>Fe  nuclei return rapidly to their ground states by two possible mechanisms: the re-emission  of </font><font face="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font><font SIZE="2" face="Verdana">-Rays  or the radiationless emission of atomic core electrons, a process known as  Internal Conversion (Krane, 1988). The probability of de-excitation by </font> <font face="Verdana"><span style="font-family: Times New Roman; color: black">&#947;</span></font><font SIZE="2" face="Verdana">-Ray  re-emission is of only 9%, so most of the <sup>57</sup></font><font SIZE="2"><font face="Verdana">Fe  excited nuclei (91%) de-excite themselves by the emission of conversion  electrons; 81% of them emit K electrons (7.3 keV kinetic energy), 9% L electrons  (13.6 keV) and 1% M electrons (14.3 keV). The emission of conversion electrons  leaves the atoms with a hole in a core level, so there is a further de-excitation  of these atoms through the emission of either characteristic X-rays or Auger  electrons. The main Auger electron signals being produced are the KLM (6.3 keV  kinetic energy), the KLL (5.4 keV), the LMM (0.65 keV) and the MVV (0.047 keV).  Secondary, low energy, electrons are also produced in the process. We see that  there is an important amount of electronic signals that are consequence of the  resonant absorption of </font></font><font face="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font><font SIZE="2"><font face="Verdana">-Rays  which then could be used to perform Mössbauer Spectroscopy if these signals are  properly detected. The spectra obtained in this fashion are emission spectra and  the technique is known as Conversion Electron Mössbauer Spectroscopy (CEMS) [Nomura  et al. 1996]. Superimposed to the mentioned Mössbauer&nbsp; electron signals  there are also non resonant electron signals contributing to the spectrum  background, produced mainly by photoelectric and Compton effects due to the  interaction with the sample of the </font></font><font face="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font><font SIZE="2"><font face="Verdana">  and X-rays emitted by the source. As electrons are particles with electric  charge, in general they interact with matter more strongly than </font></font> <font face="Verdana"><span style="font-family: Times New Roman; color: black">&#947;</span></font><font SIZE="2"><font face="Verdana">  or X-Rays do, so one expects that the electrons that escape from the sample in  Conversion Electron Mössbauer Spectroscopy come from a region close enough to  the sample surface that they could be used in the characterization of surfaces,  interfaces and thin films. </font></p> </font><font FACE="Verdana" SIZE="2"><b>     ]]></body>
<body><![CDATA[<p ALIGN="JUSTIFY">EXPERIMENTAL TECHNIQUES </p> </b></font><font SIZE="2">     <p ALIGN="JUSTIFY"><font face="Verdana">The chamber where the spectrometer was  installed is shown in <a href="#fig1">Figure 1</a>. It is a cylindrical  stainless steel UHV chamber used for the characterization of metal surfaces by  Auger Electron Spectroscopy and Low Energy Electron Diffraction. It has a front  glass viewport, several ports of different sizes and a sample manipulator,  located at the top, with capacity for x, y and z displacements, 360º rotation  around a vertical axis and ±50º tilt around a horizontal axis.</font></p>     <p ALIGN="center"><a name="fig1"> <img border="0" src="/img/fbpe/rfiucv/v27n4/art09fig1.gif" width="311" height="332" align="center"></a></p> <font FACE="Verdana" SIZE="2"><i><b>     
<p align="center">Figure 1. </b>UHV chamber where the CEMS analyzer was  installed </p> </i></font>     <p ALIGN="JUSTIFY"><font face="Verdana">It is convenient that the different  parts of the spectrometer be assembled onto a single flange in order to  facilitate its installation in this chamber or in similar ones. For this purpose  the 20 cm flange located at the left in <a href="#fig1">Figure 1</a> was chosen.  The sample could be positioned as usual in the manipulator in order to face this  spectrometer and other ones installed in the chamber simply by rotating it  around the vertical axis. It is also desirable that the radioactive source be  kept outside the chamber in order to avoid heating it when the chamber is baked  out and to be able to use it in another experimental set up, if needed, without  breaking the vacuum. This can be done by using a Beryllium window, capable of  sustaining UHV conditions and being transparent to the 14.4 keV <span style="font-family: Times New Roman; color: black">&#947;</span>-Rays. Given  the dimensions of the chamber, it was difficult to place the source close to the  sample in order to irradiate it with sufficient intensity, so it was necessary  to include in the design a stainless steel tube, 25 mm diameter and 115 mm long,  welded to the flange at the central position, that extends itself into the  chamber and is closed at the end by a 550 &#956;m thick Beryllium window. This tube  was lined with a lead foil for shielding purposes and had at the end a 3 mm  thick lead disk with a 9 mm diameter circular aperture that acts as a collimator  of the <span style="font-family: Times New Roman; color: black">&#947;</span>-Rays.  Additionally it contains a 1.5 mm thick Plexiglas® disk that acts as a filter  for attenuating the parasitic X-Rays produced by the radioactive source. </font> </p>     <p ALIGN="JUSTIFY"><font face="Verdana">The electron detector was fixed to a  stainless steel rod, welded to the internal part of the 20 cm flange, through a  sliding support that allows moving it close to the sample and tilting it in  order to face the sample surface. On the same flange were also welded three  electrical feedthroughs in order to make the electrical connections needed for  the electron multiplier operation. <a href="#fig2">Figure 2</a> shows a picture  of the assembled parts onto the 20 cm diameter flange.</font></p>     <p ALIGN="center"><a name="fig2"> <img border="0" src="/img/fbpe/rfiucv/v27n4/art09fig2.gif" width="269" height="245" align="center"></a></p> <font FACE="Verdana" SIZE="2"><i><b>     
<p align="center">Figure 2. </b>Assembly of the CEMS spectrometer onto the 20 cm  diameter flange </p> </i></font></font><font SIZE="2">     <p ALIGN="JUSTIFY"><font face="Verdana">The electron detector used, shown in <a href="#fig3">Figure 3</a>, was a DeTech 512 Channel-electron-multiplier,  operated in the pulse counting mode although it was originally designed to  operate in the current mode as part of an Auger Electron Spectrometer. This  device has a 19 mm input aperture and requires electrical connections for high  voltage bias, input cone bias and signal collector (BURLE, 2009). This electron  multiplier is bakeable and normally works under high or ultra-high vacuum  conditions, giving a maximum gain of 10</font></font><sup><font SIZE="2" face="Verdana">6</font></sup><font SIZE="2"><font face="Verdana">.  The circuit diagram of <a href="#fig4">Figure 4</a> shows the connections used  for its operation. The graph of <a href="#fig5">Figure 5</a> shows its detection  efficiency as a function of the kinetic energy of the electrons impinging on the  surface of its entrance cone; it acts as a high-pass filter whose efficiency  drops abruptly for kinetic energies below 500 eV.</font></font></p>     <p ALIGN="center"><a name="fig3"> <img border="0" src="/img/fbpe/rfiucv/v27n4/art09fig3.gif" width="335" height="224" align="center"></a></p> <i><font SIZE="2" face="Verdana"><b>     
]]></body>
<body><![CDATA[<p ALIGN="center">Figure 3. </b>DeTech 512 channel electron multiplier used as  electron detector</p>     <p ALIGN="center"><a name="fig4"> <img border="0" src="/img/fbpe/rfiucv/v27n4/art09fig4.jpg" width="362" height="265" align="center"></a></p> <b>     
<p align="center">Figure 4. </b>Circuit diagram used to operate the channel  electron multiplier. R = 1 M&#937;, C= 1.5 nF</p>     <p align="center"><a name="fig5"> <img border="0" src="/img/fbpe/rfiucv/v27n4/art09fig5.gif" width="325" height="271" align="center"></a></p> <b>     
<p align="center">Figure 5. </b>Typical channel electron multiplier efficiency  curve for electron detection. Plotted from data given in (BURLE, 2009) </p> </font></i><font SIZE="2">     <p align="justify"><font face="Verdana">The radioactive source used was a 10 mm  diameter disc of </font></font><sup><font SIZE="2" face="Verdana">57</font></sup><font SIZE="2"><font face="Verdana">Co  in a Rh matrix which was placed at the end of an extension rod, connected to the  velocity transducer and inserted into the lead-lined tube at approximately 15 mm  from the collimator aperture. </font></p> </font><font SIZE="2">     <p ALIGN="JUSTIFY"><font face="Verdana">In order to get the maximum electron  signal, the sample was positioned opposite to the Beryllium window but tilted  45º downwards and the electron multiplier was tilted 45º upwards in order to  face the sample. The distances window to sample and sample to electron  multiplier were about 5 cm. </font></p>     <p ALIGN="JUSTIFY"><font face="Verdana">The external system required for spectra  acquisition consists of the following components: </font></p> <dir> 	    <p ALIGN="JUSTIFY"><font face="Verdana">a) A drive unit for the control of  	the velocity transducer. </font></p> 	    <p ALIGN="JUSTIFY"><font face="Verdana">b) A 2000-3000 V high voltage power  	supply for biasing the electron multiplier. </font></p> 	    ]]></body>
<body><![CDATA[<p ALIGN="JUSTIFY"><font face="Verdana">c) A 0-200 V power supply for  	biasing the entrance cone of the electron multiplier. </font></p> 	    <p ALIGN="JUSTIFY"><font face="Verdana">d) A preamplifier for decoupling the  	output pulses of the electron multiplier from the high voltage bias,  	converting the charge into a proportional voltage signal. </font></p> 	    <p ALIGN="JUSTIFY"><font face="Verdana">e) An amplifier for pulse shaping  	and amplifying the output pulses. </font></p> 	    <p ALIGN="JUSTIFY"><font face="Verdana">f) A single channel analyzer for  	transforming output pulses of the amplifier into logical pulses after  	discriminating them by the use of a selecting window. </font></p> 	    <p ALIGN="JUSTIFY"><font face="Verdana">g) A multichannel analyzer for  	accumulating the Mössbauer spectra as histograms of number of counts as a  	function of channel number, by receiving the pulses from the single channel  	analyzer and synchronizing the repetitive signal from the drive unit. We  	used the multichannel scaling data acquisition module CMCA- 550 from WISSEL. 	</font></p> 	    <p ALIGN="JUSTIFY"><font face="Verdana">h) A personal computer for receiving,  	storing and processing the spectra. </font></p> </dir>     <p ALIGN="JUSTIFY"><font face="Verdana">The processing of the Mössbauer spectra  includes a folding of the experimental data corresponding to the positive and  negative velocity ramps and a least-squares fitting of the folded spectra with  Lorentzian peaks. As a result of the fitting procedure the hyperfine parameters  that characterize the sample are determined. In our case the spectra processing  was carried out with the program &quot;Recoil&quot;® 1.0 (Lagarec &amp; Rancourt, 1998).</font></p> </font><font FACE="Verdana" SIZE="2"><b>     <p ALIGN="JUSTIFY">RESULTS AND DISCUSSION </p> </b>     <p ALIGN="JUSTIFY">The<sup> 57</sup>Co/Rh radioactive source used is shielded at  the back so the &#947; radiation is emitted mainly in the forward direction. One  advantage of the conventional absorption mode is that the &#947; absorption process  is detected in the direction of the emission of the <font face="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font>-Rays by  the radioactive source, so in principle all the transmitted signal is detected.  On the other hand, the signals emitted by the atoms in the absorber as a  consequence of the desexcitation process of their excited nuclei, travel with  equal probability in all directions; the detected signal in this case is only a  fraction of the emitted one since it is proportional to the solid angle  subtended by the detector entrance. </p>     <p ALIGN="JUSTIFY">Given the geometry of our Mössbauer Emission Spectrometer, it  is important to know the area irradiated on the sample position in order to  determine the optimum size of the sample to be used. This was determined using  an X-Ray dental film to measure the exposed area. <a href="#fig6">Figure 6</a>  shows a picture of the exposed film in which one observes a dark shadow  corresponding to the irradiated area; it is elliptical since the film was placed  on the sample holder, tilted 45º. The clear disk superposed on the dark shadow  corresponds to the 25 mm diameter circular sample used in our measurements,  placed on top of the exposed film. One observes that the whole sample area is  irradiated by the </font><font face="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font><font FACE="Verdana" SIZE="2">-Rays.</p>     ]]></body>
<body><![CDATA[<p ALIGN="center"><a name="fig6"> <img border="0" src="/img/fbpe/rfiucv/v27n4/art09fig6.gif" width="335" height="231" align="center"></a></p> <i><b>     
<p ALIGN="center">Figure 6. </b>Image of an X-Ray film exposed to the collimated <font face="Verdana"><span style="font-family: Times New Roman; color: black">&#947;</span></font>  radiation, with a 25 mm diameter sample superimposed on it </p> </i>     <p align="justify">The effect of the Plexiglas filter can be appreciated in <a href="#fig7">Figure 7</a>, where we show energy dispersive spectra of the  source obtained both without the filter (7a) and with the filter (7b) covering  it. Besides the 14.4 keV <font face="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font>-Ray  signal, we observe in <a href="#fig7">Figure 7a</a> the presence of the 6.40 keV  Fe K&#945; , the 7.06 keV Fe K&#946; and the 20.21 keV Rh K&#945; X-Ray signals. The Fe K  signal is the result of the de-excitation of the iron atoms produced in the 57Co  electron capture process, while the Rh K signal is the result of fluorescence  caused by the high energy <font face="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font>-Rays on  the Rh matrix. With the Plexiglas filter, we see in <a href="#fig7">Figure 7b</a>  that the Fe K signal disappears without reducing much the 14.4 keV <font face="Verdana"><span style="font-family: Times New Roman; color: black">&#947;</span></font>-Ray  signal. According to these spectra, the use of the filter reduces the intensity  of the 14.4 keV <font face="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font>-Rays to  72% of its original value. However, in this case 86% of the photons that  irradiate the sample are the 14.4 keV <font face="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font>-Ray  photons and only 14% are X-Ray photons; while without the filter, 60% of photons  that irradiate the sample are the 14.4 keV <font face="Verdana"> <span style="font-family: Times New Roman; color: black">&#947;</span></font>-Ray  photons and 40% are the X-Rays photons, which contribute to the spectrum noise  by generating photoelectrons. The use of the Plexiglas filter reduces the non-resonant  electron signals by eliminating the Fe K X-Rays generated by the radioactive  source.</p>     <p align="center"><a name="fig7"><img border="0" src="/img/fbpe/rfiucv/v27n4/art09fig7.gif"></a></p> <i><b>     
<p align="center">Figure 7. </b>Energy dispersive emission spectra of the <sup> 57</sup>Co(Rh) radioactive source. a) without the Plexiglas filter, b) with the  Plexiglas filter</p> </i>     <p ALIGN="JUSTIFY"><a href="#fig8">Figure 8</a> compares an emission conversion  electron Mössbauer spectrum from an iron plate with a conventional absorption  Mössbauer spectrum from a 6.4 &#956;m thick iron foil. The acquisition time was about  24 hours for both spectra, although the source activity was 30 mCi in the  emission experiment and 6 mCi in the absorption one. As expected, both spectra  consist of a sextet whose hyperfine parameters agree with those corresponding to  &#945;-iron. The signal to noise ratio is clearly smaller in the CEMS spectrum  despite the larger source activity that was used. In the case of the absorption  spectrum the sample region generating the Mössbauer signals corresponds to the  whole thickness, i.e. 6.4 &#956;m. In the case of the emission spectrum the  mean-escape-depth of the signals from metallic iron detected by our spectrometer  has been calculated to correspond to approximately only 80 nm, taking into  account both the conversion electrons and the Auger electrons, as well as the  coincidence effects in their detection (Moutinho et al. 2010).</p>     <p ALIGN="center"><a name="fig8"> <img border="0" src="/img/fbpe/rfiucv/v27n4/art09fig8.gif" width="322" height="273" align="center"></a></p> </font><i><font FACE="Verdana" SIZE="2"><b>     
<p ALIGN="center">Figure 8. </b>CEMS Emission (&#9675;) and Conventional Absorption  (&#9679;) Mössbauer spectra from &#945;-iron </p> </font></i><font SIZE="2" face="Verdana">     <p ALIGN="JUSTIFY"><a href="#fig9">Figure 9</a> shows a conversion electron  Mössbauer spectrum, obtained with the designed CEMS spectrometer, corresponding  to a 100 nm Fe thin film deposited on a 304 stainless steel plate. One observes  the superposition of two sub-spectra; the sextet characteristic of the &#945;-iron  from the film and the central singlet characteristic of the non-magnetic  stainless steel substrate. The main contribution to the total detected signal  comes from the Fe(K) conversion electrons, which provide information from a  surface region of about 200 nm thick. Thus, although the mean-escape-depth of  the CEMS signal in &#945;-iron is smaller than the iron film thickness, the  contribution of Fe(K) conversion electrons provides information about the  underlying substrate, what explains the comparable importance in the spectrum of  both the &#945;-iron film and the stainless steel substrate components. The Auger  electrons resonant signals are in principle more surface sensitive than the  conversion electrons signals, but our spectrometer cannot discriminate between  them as it adds or integrates all these different electron signals. This type of  spectrometer is known as an Integral Conversion Electron Mössbauer Spectrometer  (ICEMS). An energy selective Mössbauer spectrometer, or Differential Conversion  Electron Mössbauer Spectrometer (DCEMS), capable of differentiate each type  electron signal, tuning in this way its surface sensitivity, is under  construction.</p>     <p ALIGN="center"><a name="fig9"> <img border="0" src="/img/fbpe/rfiucv/v27n4/art09fig9.gif" width="321" height="268" align="center"></a></p> <i><b>     
]]></body>
<body><![CDATA[<p align="center">Figure 9. </b>CEMS spectrum corresponding to a 100 nm Fe film  deposited on a 304 stainless steel plate</p> </i><b>     <p ALIGN="JUSTIFY">CONCLUSSIONS </p> </b></font><font SIZE="2">     <p ALIGN="JUSTIFY"><font face="Verdana">An ICEMS Mössbauer spectrometer for  surface studies in iron containing samples was designed and successfully  constructed. It is based in the use of a channel electron multiplier for the  detection of the integrated conversion and Auger electron signals emitted by the </font></font><font SIZE="2" face="Verdana">57</font><font SIZE="2"><font face="Verdana">Fe  isotopes as a consequence of the resonant nuclear absorption of &#947;-Rays. As this  spectrometer is contained within a single flange it can be easily installed in  any conventional ultra- high vacuum chamber dedicated to surface physics studies,  enhancing in this way its analytical capability. </font></p> </font><font FACE="Verdana" SIZE="2"><b>     <p ALIGN="JUSTIFY">ACNOWLEDGMENTS </p> </b>     <p ALIGN="JUSTIFY">The advice of Dr. Ramón Gancedo, from the Instituto de  Química Física Rocasolano, Madrid, Spain, and the financial support from CDCH-UCV  under Project PI 03005566- 2004 and from FONACIT under Project G-2005000449 are  gratefully acknowledged. </p> </font><b><font SIZE="2" face="Verdana">     <p ALIGN="JUSTIFY">REFERENCES</p> </b>     <!-- ref --><p ALIGN="JUSTIFY">1.<b> </b></font><font SIZE="2" face="Verdana">Burle  IndustriesInc. </font><font face="Verdana" SIZE="2">(2009). Channeltron Electron  Multiplier Handbook for Mass Spectrometry Applications. Downloaded on 15 July  2009 from <a href="http://www.burle.com/cgi/byteserver.pl/pdf/ChannelBook.pdf"> www.burle.com/cgi/byteserver.pl/pdf/ChannelBook.pdf</a> </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1885662&pid=S0798-4065201200040000900001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p ALIGN="JUSTIFY"><font face="Verdana" size="2">2. Desimoni, J., Ramos, C.P.,  Arcondo, B., Saccone, F.D., Mercader, R.C. Eds. </font> <font face="Verdana" SIZE="2">(2009). LACAME 2008: Proceedings of the 11th Latin  American Conference on the Applications of the Mössbauer effect, held in La  Plata, 9-14 November 2008. Springer, 3-4.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1885663&pid=S0798-4065201200040000900002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p ALIGN="JUSTIFY"><font face="Verdana" size="2">4. Krane, K.S. </font> <font SIZE="2"><font face="Verdana">(1988). Introductory Nuclear Physics. John  Wiley &amp; Sons, 341-348.</font></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1885664&pid=S0798-4065201200040000900003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p ALIGN="JUSTIFY"><font face="Verdana" size="2">5. L</font><font FACE="Verdana" SIZE="2">agarec,  K. &amp; Rancourt, D. G. (1998). Recoil, Mössbauer Spectral Analysis Software for  Windows, version 1.0. Department of Physics, University of Ottawa. 1-40.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1885665&pid=S0798-4065201200040000900004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p ALIGN="JUSTIFY"><font face="Verdana" size="2">6. Moutinho, F., Rojas, C.,  D’Onofrio, L. (2010). Design of a Conversion Electron Mössbauer Spectrometer  based on an Electron Multiplier. Evaluation of the Mean-escape-depth of the  Detected Signals. Hyperfine Interactions, 195, pp. 141-147.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1885666&pid=S0798-4065201200040000900005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p ALIGN="JUSTIFY"><font face="Verdana" size="2">7. Nomura, K., Jihira, Y.,  Vertes, A. </font><font FACE="Verdana" SIZE="2">(1996). Applications of  Conversion Electron Mössbauer Spectrometry (CEMS). Journal of Radioanalytical  and Nuclear Chemistry, 202, pp. 103-199. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1885667&pid=S0798-4065201200040000900006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="Verdana">8. O</font></font><font SIZE="2" face="Verdana">vchinnikov,  V.V. (2006). Mössbauer Analysis of the Atomic and Magnetic Structure of Alloys.  Cambridge International Science Publishing Ltd., pp. 1-260.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1885668&pid=S0798-4065201200040000900007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body>
<back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="">
<collab>Burle IndustriesInc</collab>
<source><![CDATA[Channeltron Electron Multiplier Handbook for Mass Spectrometry Applications]]></source>
<year>2009</year>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Desimoni]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Ramos]]></surname>
<given-names><![CDATA[C.P]]></given-names>
</name>
<name>
<surname><![CDATA[Arcondo]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Saccone]]></surname>
<given-names><![CDATA[F.D]]></given-names>
</name>
<name>
<surname><![CDATA[Mercader]]></surname>
<given-names><![CDATA[R.C]]></given-names>
</name>
</person-group>
<source><![CDATA[LACAME 2008]]></source>
<year>2009</year>
<conf-name><![CDATA[ Proceedings of the 11th Latin American Conference on the Applications of the Mössbauer effect, held in La Plata, 9-14 November 2008]]></conf-name>
<conf-loc> </conf-loc>
<page-range>3-4</page-range><publisher-name><![CDATA[Springer]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<label>4</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Krane]]></surname>
<given-names><![CDATA[K.S]]></given-names>
</name>
</person-group>
<source><![CDATA[Introductory Nuclear Physics]]></source>
<year>1988</year>
<page-range>341-348</page-range><publisher-name><![CDATA[John Wiley & Sons]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<label>5</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lagarec]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Rancourt]]></surname>
<given-names><![CDATA[D. G]]></given-names>
</name>
</person-group>
<source><![CDATA[Recoil, Mössbauer Spectral Analysis Software for Windows, version 1.0]]></source>
<year>1998</year>
<page-range>1-40</page-range><publisher-name><![CDATA[Department of Physics, University of Ottawa]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<label>6</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moutinho]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Rojas]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[D’Onofrio]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<source><![CDATA[Design of a Conversion Electron Mössbauer Spectrometer based on an Electron Multiplier: Evaluation of the Mean-escape-depth of the Detected Signals]]></source>
<year>2010</year>
<volume>195</volume>
<page-range>141-147</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nomura]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Jihira]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Vertes]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Applications of Conversion Electron Mössbauer Spectrometry (CEMS)]]></article-title>
<source><![CDATA[Journal of Radioanalytical and Nuclear Chemistry]]></source>
<year>1996</year>
<volume>202</volume>
<page-range>103-199</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>8</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ovchinnikov]]></surname>
<given-names><![CDATA[V.V]]></given-names>
</name>
</person-group>
<source><![CDATA[Mössbauer Analysis of the Atomic and Magnetic Structure of Alloys]]></source>
<year>2006</year>
<page-range>1-260</page-range><publisher-name><![CDATA[Cambridge International Science Publishing Ltd]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
