<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0798-4065</journal-id>
<journal-title><![CDATA[Revista de la Facultad de Ingeniería Universidad Central de Venezuela]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Fac. Ing. UCV]]></abbrev-journal-title>
<issn>0798-4065</issn>
<publisher>
<publisher-name><![CDATA[Universidad Central de Venezuela]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0798-40652015000300005</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Concentración y relación de PST, PM10 Y PM2.5 en poblaciones cercanas a minería a cielo abierto: Caso Cerrejón Colombia]]></article-title>
<article-title xml:lang="en"><![CDATA[Concentration and ratio PST, PM10 AND PM2.5 in towns near open pit mining: Case Cerrejón Colombia]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rojano]]></surname>
<given-names><![CDATA[Roberto]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Angulo]]></surname>
<given-names><![CDATA[Luis]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Restrepo]]></surname>
<given-names><![CDATA[Gloria]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de Antioquia Facultad de Ingeniería Departamento de Ingeniería Química]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>09</month>
<year>2015</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>09</month>
<year>2015</year>
</pub-date>
<volume>30</volume>
<numero>3</numero>
<fpage>39</fpage>
<lpage>48</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_arttext&amp;pid=S0798-40652015000300005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_abstract&amp;pid=S0798-40652015000300005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_pdf&amp;pid=S0798-40652015000300005&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Muestras de PM2.5, PM10 y partículas suspendidas totales (PST) fueron recogidas entre enero y junio de 2012 en la Mina a cielo abierto el Cerrejón, al norte de Colombia. Mediciones de 24 horas cada seis días fueron realizadas utilizando muestreadores de alto volumen para PM10 y PST y bajo volumen para PM2.5. Las concentraciones variaron entre 18,20 y 198,2 &#956;g/m³ para PST, 11,96 &#956;g/m³ y 100,05 &#956;g/m³ para PM10 y 54,50 &#956;g/m³ y 3,37 &#956;g/m³ para PM2.5. Las máximas concentraciones se registraron en las estaciones ubicadas viento abajo de los tajos de explotación. Las relaciones de PM10/ PST registraron valores entre 0,12 a 0,93 y las de PM2.5/PM10 entre 0,33 y 0,51. También se observó correlación lineal significativa en PST/PM10 (R= 0,81, 0,85, 0,77, 0,71, 0,69) y correlación lineal no significativa en PM2.5/PM10 (R = 0,10 y 0,14). Las PST pueden ser una variable predictiva de PM10 en la zona minera del Cerrejón mientras que las PM10 no pueden ser utilizadas para predecir con confianza la concentración de PM2.5 en la misma zona. Los resultados revelaron variabilidad significativa en las concentraciones de PST en relación a PM10 y PM2.5 dependiendo de la ubicación de las estaciones con respecto a los tajos de explotación.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[PM2.5, PM10 and total suspended particles (TSP) samples were collected from January to June 2012 in the open pit mine Cerrejón north of Colombia. Measurements of 24 hours every six days were made using PM10 and TSP High Volume air sampler and PM2.5 Low Volume. Concentrations were 18.20 to 198.2 &#956;g/m³ for TSP, 11.96 &#956;g/m³ to 100.05 &#956;g/m³ for PM10 and 54.50 &#956;g/m³ to 3.37 &#956;g/m³ for PM2.5. The maximum concentrations were recorded at stations located downwind of the pits. Relations PM10/TSP ranged 0.12 to 0.93 and the PM2.5/PM10 0.33 to 0.51. Was also observed significant linear correlation in TSP/PM10 (R= 0.81, 0.85, 0.77, 0.71, 0.69) and no significant linear correlation in PM2.5-PM10 (R = 0.10 y 0.14). The TSP may be a predictor of PM10 in the mining area Cerrejón, whereas PM10 can not be used to predict the concentration of PM2.5 in the same area. The results revealed significant variability in the concentrations of TSP in relation to PM10 and PM2.5 depending on the location of the stations with respect to the pits of exploitation.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[PST]]></kwd>
<kwd lng="es"><![CDATA[PM10]]></kwd>
<kwd lng="es"><![CDATA[PM2.5]]></kwd>
<kwd lng="es"><![CDATA[muestreo]]></kwd>
<kwd lng="es"><![CDATA[relación]]></kwd>
<kwd lng="es"><![CDATA[concentración]]></kwd>
<kwd lng="es"><![CDATA[tajo]]></kwd>
<kwd lng="es"><![CDATA[Colombia]]></kwd>
<kwd lng="en"><![CDATA[TSP]]></kwd>
<kwd lng="en"><![CDATA[PM10]]></kwd>
<kwd lng="en"><![CDATA[PM2.5]]></kwd>
<kwd lng="en"><![CDATA[sampling]]></kwd>
<kwd lng="en"><![CDATA[relation]]></kwd>
<kwd lng="en"><![CDATA[concentration]]></kwd>
<kwd lng="en"><![CDATA[pit]]></kwd>
<kwd lng="en"><![CDATA[Colombia]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p style="text-autospace: none" align="center"><font face="Verdana"><b> <span style="font-family: TimesNewRomanPS-BoldMT">Concentración y relación de  PST, PM<sub>10</sub> Y PM<sub>2.5</sub> en poblaciones cercanas a minería a  cielo abierto: Caso Cerrejón Colombia</span></b></font></p>     <p style="text-autospace: none" align="center"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPS-ItalicMT-SC700"> Roberto Rojano </span><sup> <span style="font-family: TimesNewRomanPS-ItalicMT-SC700"><font size="2">1, 2</font></span></sup><span style="font-size: 10.0pt; font-family: TimesNewRomanPS-ItalicMT-SC700">,  Luis Angulo </span><sup> <span style="font-family: TimesNewRomanPS-ItalicMT-SC700"><font size="2">1, 2</font></span></sup><span style="font-size: 10.0pt; font-family: TimesNewRomanPS-ItalicMT-SC700">,  Gloria Restrepo </span><sup> <span style="font-family: TimesNewRomanPS-ItalicMT-SC700"><font size="2">2</font></span></sup></font></p>     <p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-family: TimesNewRomanPSMT"><font size="2"><sup>1</sup> </font> </span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> Universidad de La Guajira, Facultad de Ingeniería, Grupo de Investigación GISA.  email: <a style="color: blue; text-decoration: underline; text-underline: single" href="mailto:rrojano@uniguajira.edu.co"> rrojano@uniguajira.edu.co</a></span></font></p>     <p align="justify"><font face="Verdana"> <span style="font-family: TimesNewRomanPSMT"><font size="2"><sup>2</sup> </font> </span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> Universidad de Antioquia, Facultad de Ingeniería, Departamento de Ingeniería  Química, Grupo Procesos </span> <span lang="PT-BR" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> Fisicoquímicos Aplicados. email: <a style="color: blue; text-decoration: underline; text-underline: single" href="mailto:gloma@udea.edu.co"> gloma@udea.edu.co</a></span></font></p>     <p align="justify"><b><font size="2" face="Verdana">RESUMEN</font></b></p>     <p align="justify"><font size="2" face="Verdana">Muestras de PM<sub>2.5</sub>,  PM<sub>10</sub> y partículas suspendidas totales (PST) fueron recogidas entre  enero y junio de 2012 en la Mina a cielo abierto el Cerrejón, al norte de  Colombia. Mediciones de 24 horas cada seis días fueron realizadas utilizando  muestreadores de alto volumen para PM<sub>10</sub> y PST y bajo volumen para PM<sub>2.5</sub>.  Las concentraciones variaron entre 18,20 y 198,2 &#956;g/m<sup>3</sup> para PST,  11,96 &#956;g/m<sup>3</sup> y 100,05 &#956;g/m<sup>3</sup> para PM<sub>10</sub> y 54,50 &#956;g/m<sup>3</sup>  y 3,37 &#956;g/m<sup>3</sup> para PM<sub>2.5</sub>. Las máximas concentraciones se  registraron en las estaciones ubicadas viento abajo de los tajos de explotación.  Las relaciones de PM<sub>10</sub>/ PST registraron valores entre 0,12 a 0,93 y  las de PM<sub>2.5</sub>/PM<sub>10</sub> entre 0,33 y 0,51. También se observó  correlación lineal significativa en PST/PM<sub>10</sub> (R= 0,81, 0,85, 0,77,  0,71, 0,69) y correlación lineal no significativa en PM<sub>2.5</sub>/PM<sub>10</sub>  (R = 0,10 y 0,14). Las PST pueden ser una variable predictiva de PM<sub>10</sub>  en la zona minera del Cerrejón mientras que las PM<sub>10</sub> no pueden ser  utilizadas para predecir con confianza la concentración de PM<sub>2.5</sub> en  la misma zona. Los resultados revelaron variabilidad significativa en las  concentraciones de PST en relación a PM<sub>10</sub> y PM<sub>2.5</sub>  dependiendo de la ubicación de las estaciones con respecto a los tajos de  explotación.</font></p>     <p align="justify"><font face="Verdana"><b><font size="2">Palabras clave:</font></b><font size="2">  PST, PM<sub>10</sub>, PM<sub>2.5</sub>, muestreo, relación, concentración, tajo,  Colombia</font></font></p>     <p style="text-autospace: none" align="center"><font face="Verdana"><b> <span lang="EN-US" style="font-family: TimesNewRomanPS-BoldMT"><font size="2"> Concentration and ratio PST, PM</font></span><sub><span lang="EN-US" style="font-family: TimesNewRomanPS-BoldMT"><font size="2">10</font></span></sub><span lang="EN-US" style="font-family: TimesNewRomanPS-BoldMT"><font size="2">  AND PM</font></span><sub><span lang="EN-US" style="font-family: TimesNewRomanPS-BoldMT"><font size="2">2.5</font></span></sub><span lang="EN-US" style="font-family: TimesNewRomanPS-BoldMT"><font size="2">  in towns near open pit mining: Case Cerrejón Colombia</font></span></b></font></p>     <p style="text-autospace: none" align="justify"><b> <font size="2" face="Verdana">ABSTRACT</font></b></p>     <p style="text-autospace: none" align="justify"><font size="2" face="Verdana">PM<sub>2.5</sub>,  PM<sub>10</sub> and total suspended particles (TSP) samples were collected from  January to June 2012 in the open pit mine Cerrejón north of Colombia.  Measurements of 24 hours every six days were made using PM<sub>10</sub> and TSP  High Volume air sampler and PM<sub>2.5</sub> Low Volume. Concentrations were  18.20 to 198.2 &#956;g/m<sup>3</sup> for TSP, 11.96 &#956;g/m<sup>3</sup> to 100.05 &#956;g/m<sup>3</sup>  for PM<sub>10</sub> and 54.50 &#956;g/m<sup>3</sup> to 3.37 &#956;g/m<sup>3</sup> for PM<sub>2.5</sub>.  The maximum concentrations were recorded at stations located downwind of the  pits. Relations PM<sub>10</sub>/TSP ranged 0.12 to 0.93 and the PM<sub>2.5</sub>/PM<sub>10</sub>  0.33 to 0.51. Was also observed significant linear correlation in TSP/PM<sub>10</sub>  (R= 0.81, 0.85, 0.77, 0.71, 0.69) and no significant linear correlation in PM<sub>2.5</sub>-PM<sub>10</sub>  (R = 0.10 y 0.14). The TSP may be a predictor of PM<sub>10</sub> in the mining  area Cerrejón, whereas PM<sub>10</sub> can not be used to predict the  concentration of PM<sub>2.5</sub> in the same area. The results revealed  significant variability in the concentrations of TSP in relation to PM<sub>10</sub>  and PM<sub>2.5</sub> depending on the location of the stations with respect to  the pits of exploitation.</font></p>     ]]></body>
<body><![CDATA[<p style="text-autospace: none" align="justify"><font face="Verdana"><b> <font size="2">Keywords:</font></b><font size="2"> TSP, </font></font> <font size="2" face="Verdana">PM<sub>10</sub></font><font size="2" face="Verdana">, </font><font size="2" face="Verdana">PM<sub>2.5</sub></font><font size="2" face="Verdana">,  sampling, relation, concentration, pit, Colombia.</font></p>     <p style="text-autospace: none" align="justify"><font size="2" face="Verdana"> Recibido: octubre 2014 Recibido en forma final revisado: julio 2015</font></p>     <p align="justify"><font face="Verdana" size="2"><b>INTRODUCCIÓN</b></font></p>     <p align="justify"><font face="Verdana" size="2">Colombia es el primer productor  de carbón de América Latina y el decimosegundo del mundo. Sus reservas totales  se estiman en alrededor de 17 mil millones de toneladas, de las cuales se han  medido 7 mil millones. La proyección nacional de oferta de carbón por distrito  estimada para el año 2014, según la Unidad de Planeación Minero Energética de  Colombia (UPME), es de 124.9 millones de toneladas, de la cuales casi el 90%  corresponde a extracción a cielo abierto (UPME, 2006). La minería de carbón a  cielo abierto genera mayores impactos al medio ambiente que la minería  subterránea. En particular, causa deterioro a la calidad del aire debido al  material particulado y a los contaminantes gaseosos emitidos a la atmósfera (Ghose  &amp; Majee, 2007). Todas las operaciones que impliquen movimientos de tierra o  carbón o la exposición de las superficies erosionables, generan polvo fugitivo (USEPA,  1998). El material transportado ha sido identificado como la principal fuente de  contaminación del aire, especialmente las partículas suspendidas totales (PST) y  las partículas menores de 10 micras (PM<sub>10</sub>) (USEPA, 1988; Ghose &amp;  Majee, 2000). Las fuentes de contaminación del aire en áreas de extracción de  carbón generalmente incluyen actividades como perforación, voladura, carga y  descarga de material estéril, carga y descarga del carbón, apilamiento de  carbón, vías de acarreo, vías de transporte, botaderos de escombros, planta de  manejo de carbón, pilas de almacenaje de carbón y estéril y mantenimientos de  vías (CMRI, 1999). Entre los distintos contaminantes del aire, el material  particulado muestra fuerte evidencia de efectos adversos en la salud como la  disminución de la función pulmonar, dificultad respiratoria e hipoxemia, cambios  adversos en la función autonómica cardíaca (Dostal <i>et al</i>., 2013;  Muránszky <i>et al</i>., 2011; Pope &amp; Dockery, 2006). Otros estudios lo han  asociado con excesos en la morbilidad y mortalidad (Hoek <i>et al</i>., 2013;  Brunekreef &amp; Holgate, 2002). Una disminución de 10 &#956;g/m<sup>3</sup> en la  concentración de las partículas finas se asoció con un aumento estimado en la  media de esperanza de vida de 0,61 a 0,81 años (Pope <i>et al</i>., 2009). Van-Steenis  (2008) confirmó que el material particulado fino y ultra fino (PM<sub>10</sub>,  PM<sub>2.5</sub> y PM1) causó un aumento en el asma al 33% de niños que viven a  una milla de una mina de carbón a cielo abierto, con un aumento acumulado de 21%  a dos millas e incluso hasta un 12% a menos tres millas. De igual manera, se ha  registrado que cuando la producción de carbón se incrementa, la tasa de la  enfermedad cardiopulmonar, la enfermedad pulmonar, la enfermedad cardiovascular,  la diabetes y la enfermedad renal aumentan (Hendryx &amp; Zullig, 2009). En  Colombia, la Resolución 650 de 2010, por la cual se adopta el Protocolo para el  Monitoreo y Seguimiento de la Calidad del Aire, establece Sistemas Especiales de  Vigilancia de Calidad de Aire (SEVCA) a cualquier población con problemáticas  específicas de calidad del aire como minería y alto nivel de industrialización (MAVDT,  2010). Estas minas de explotación a cielo abierto deben tener su sistema de  vigilancia de la calidad de aire especialmente para partículas PST, PM<sub>10</sub>  y PM<sub>2.5</sub>. La mina del Cerrejón cuenta con una red de trece estaciones  administrada por la autoridad ambiental de la región. Estas estaciones registran  mediciones de partícula sedimentable, TSP, PM<sub>10</sub> y PM<sub>2.5</sub>.  Para este estudio se tomaron las estaciones con muestreadores de PST, PM<sub>10</sub>  y PM<sub>2.5</sub> ubicadas en centros urbanos. El comportamientos de las  relación PST, PM<sub>10</sub> y PM<sub>2.5</sub> se usa para valorar la  composición de las partículas por tamaño y su presencia en la atmósfera (Liu <i> et al</i>., 2004) al igual que indicar la presencia en proporción de masa de un  contaminante en el otro (Zhang <i>et al</i>., 2013). La linealidad de la  relación PM<sub>2.5</sub>/PM<sub>10</sub> permite utilizar datos de PM<sub>10</sub>  para predecir con confianza la concentración de PM<sub>2.5</sub> (Echeverri &amp;  Maya, 2008; Mugica <i>et al</i>., 2002). El conocimiento de esta relación brinda  información necesaria para tomar acciones y estrategias de control más adecuadas  sobre las fuentes (Galvis &amp; Rojas, 2006). Varios autores han mostrado resultados  de la relación de estos contaminantes en zonas urbanas de ciudades con un grado  significativo de industrialización y en ciudades intermedias sin  industrialización (Galvis &amp; Rojas, 2006; Rojano <i>et al</i>., 2013). Sin  embargo, no hay evidencia en Colombia de esta relación en centros urbanos  aledaños a zonas de explotación de carbón en minería a cielo abierto. El  objetivo de este trabajo es estudiar la calidad del aire en el área de estudio y  determinar la relación entre PST, PM<sub>10</sub> y PM<sub>2.5</sub> en centros  urbanos aledaños a zonas de explotación de carbón en minería a cielo abierto,  específicamente, en la mina del Cerrejón al norte de Colombia.</font></p>     <p align="justify"><font face="Verdana" size="2"><b>MATERIALES Y MÉTODOS</b></font></p>     <p align="justify"><font face="Verdana" size="2"><b>Área de estudio</b></font></p>     <p align="justify"><font face="Verdana" size="2">El Cerrejón es una mina de  explotación de carbón a cielo abierto localizada al norte de Colombia, en el  departamento de La Guajira, frontera con Venezuela. Es una de las minas a cielo  abierto más grandes del mundo. Está ubicada en las coordenadas 11°5’2’’ Norte y  72°40’31’’ Oeste (<a href="#fig1">figura 1</a>).</font></p>     <p align="center"><a name="fig1"> <img border="0" src="/img/fbpe/rfiucv/v30n3/art05fig1.gif" width="351" height="221"></a></p>     
<p align="justify"><font face="Verdana" size="2">Los depósitos de carbón se  encuentran en una extensión de 69.000 hectáreas, dentro de la cual hay cinco  áreas de explotación denominadas tajo Patilla, tajo 100, tajo Oreganal, tajo  Tabaco y tajo La Puente (Cerrejón, 2013). La topografía del terreno es  representada por una llanura aluvial entre los sistemas montañosos de la  Serranía del Perijá por el oriente y la Sierra Nevada de Santa Marta por el  occidente. Se consideraron los receptores que forman parte de la Red de Calidad  de Aire de la Corporación Ambiental de La Guajira (Corpoguajira). Estos  receptores corresponden a poblaciones y municipios seleccionados teniendo en  cuenta la cercanía con las áreas de explotación minera.</font></p>     <p align="justify"><font face="Verdana" size="2"><b>Método de medición de PST,  PM<sub>10</sub> y PM<sub>2.5</sub>.</b></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="Verdana" size="2">Las mediciones de material  particulado PST, PM<sub>10</sub> y PM<sub>2.5</sub> se realizaron entre el 2 de  enero y el 26 de junio de 2012 en el área de influencia de la mina el Cerrejón.  Las partículas PST y PM<sub>10</sub> se determinaron por el método gravimétrico,  utilizando muestreadores de alto de volumen (Hi-Vol) con cabezal de separación  inercial para las PM<sub>10</sub>, según lo establecido en el método de  referencia para PST y PM<sub>10</sub> de la Agencia Ambiental de los Estados  Unidos (EPA, 1980; EPA, 1997). La concentración de las partículas PM<sub>2.5</sub>  se determinó utilizando un muestreador de bajo volumen (Partisol), regulado como  método equivalente de la CFR (40 CFR Part 58). El equipo cuenta con separador de  partículas finas de diámetro aerodinámico de 2.5 &#956;m, localizado en la entrada  del aire. Los filtros se mantuvieron a ± 5 °C de la temperatura ambiente. Los  equipos Hi-Vol y el Partisol operaron cada seis días con tiempo de muestreo de  24 horas, desde las 12:00 h hasta las 12:00 h del día siguiente. Se tomaron 30  muestras de material particulado PST, PM<sub>10</sub>, PM<sub>2.5</sub> en cada  estación. Se utilizaron filtros de fibra de vidrio para las PST, filtros de  fibra de cuarzo para las PM<sub>10</sub> y filtro de fibra de teflón de 47 mm  para los PM<sub>2.5</sub>. La <a href="#tab1">tabla 1</a> presenta la ubicación de las estaciones,  los equipos utilizados en el monitoreo y los parámetros medidos en cada  estación.</font></p>     <p align="center"><a name="tab1"> <img border="0" src="/img/fbpe/rfiucv/v30n3/art05tab1.gif" width="573" height="164"></a></p>     
<p align="justify"><font face="Verdana" size="2">Para la caracterización del  comportamiento meteorológico de la zona de estudio, específicamente los  parámetros que influyen en la dispersión atmosférica, se utilizaron los datos  registrados en la estación del Centro de Desarrollo Ambiental (CDA), ubicada en  el área del complejo carbonífero de Cerrejón en las coordenadas 10.09° Norte y  72.35° Oeste.</font></p>     <p align="justify"><font face="Verdana" size="2"><b>RESULTADOS Y DISCUSIÓN</b></font></p>     <p align="justify"><font face="Verdana" size="2"><b>Concentración de PST, PM<sub>10</sub>  y PM<sub>2.5</sub></b></font></p>     <p align="justify"><font face="Verdana" size="2">La <a href="#tab2">tabla 2</a> presenta el promedio  y la desviación estándar de las concentraciones de PST, PM<sub>10</sub> y PM<sub>2.5</sub>  en los cinco puntos de muestreo. El rango de las concentraciones de PST en el  muestreo varió entre 18,20 y 198,2 &#956;g/m<sup>3</sup>. El promedio geométrico  diario más alto en las concentraciones de PST fue de 106,48 &#956;g/m<sup>3</sup>  registrado en la estación Las Casitas, ubicada viento abajo de los tajos  Oreganal y 100. El promedio geométrico diario más bajo fue de 45,98 &#956;g/m<sup>3</sup>,  observado en la estación Cuestecita ubicada viento arriba de la zona de  explotación minera.</font></p>     <p align="center"><a name="tab2"> <img border="0" src="/img/fbpe/rfiucv/v30n3/art05tab2.gif" width="570" height="156"></a></p>     
<p align="justify"><font face="Verdana" size="2">Los resultados (<a href="#fig2">figura 2</a>)  muestran una diferencia estadísticas entre los promedios de las estaciones. Las  estaciones Barrancas, Patilla y Provincial presentan un comportamiento parecido;  se observa mayor dispersión en la estación Provincial, siendo esta estación la  que presenta el máximo y el mínimo nivel de PST entre todas las estaciones. El  nivel de concentración de PST encontrado en las cinco estaciones no excedieron  el nivel máximo permisibles diario para PST del Estado colombiano, que es de 300 &#956;g/ m<sup>3</sup> (MAVDT, 2010). El rango de las concentraciones de PM<sub>10</sub>  para el periodo de muestreo varió entre 11,96 &#956;g/m<sup>3</sup> y 100,05 &#956;g/m<sup>3</sup>.  La estación Barrancas reportó el mayor promedio en las concentraciones de PM<sub>10</sub>  con un nivel de 60,66 &#956;g/m<sup>3</sup> seguido de la estación Las Casitas con un  promedio de 45,50 &#956;g/m<sup>3</sup>.</font></p>     <p align="center"><a name="fig2"> <img border="0" src="/img/fbpe/rfiucv/v30n3/art05fig2.gif" width="580" height="294"></a></p>     
<p align="justify"><font face="Verdana" size="2">Los niveles más bajos se  presentaron en las estaciones Cuestecita, Patilla y Provincial con promedios de  30,20, 32,65 y 32,90 &#956;g/m<sup>3</sup>, respectivamente. Como fue mencionado, la  estación Barrancas presentó las mayores concentraciones. Esta estación no está  directamente viento abajo de los tajos Patilla y la Puente; sin embargo, está  influenciada por las emisiones del transporte interno de la ciudad. Las  estaciones Las Casitas, Cuestecitas, Patilla y Provincial presentaron  comportamiento parecido en las concentraciones de PM<sub>10</sub> con mayor  dispersión en la estación Cuestecitas. Solo una muestra en la campaña excedió el  nivel legal diario para partículas PM<sub>10</sub> del Estado colombiano, que es  de 100 &#956;g/m<sup>3</sup>, y se presentó en la estación Barrancas.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="Verdana" size="2">Los promedios diarios de PM<sub>2.5</sub>  no excedieron los niveles establecidos en la Resolución 610 de 2010. La estación  Las Casitas presentó el mayor promedio de concentración de PM<sub>2.5</sub> con  valor de 18,76 &#956;g/m<sup>3</sup>, con concentración máxima de 54,50 &#956;g/m<sup>3</sup>  y mínima de 3,37 &#956;g/m<sup>3</sup> (<a href="#fig3">figura 3</a>). En esta estación una muestra  superó el nivel legal diario en un porcentaje del 9%. La estación Barrancas  alcanzó un promedio de 17,52 &#956;g/m<sup>3</sup> con concentración máxima de 38,86  &#956;g/m<sup>3</sup> y mínima de 3,80 &#956;g/m<sup>3</sup>.</font></p>     <p align="center"><a name="fig3"> <img border="0" src="/img/fbpe/rfiucv/v30n3/art05fig3.gif" width="444" height="262"></a></p>     
<p align="justify"><font face="Verdana" size="2">Los niveles de concentración de  PST, PM<sub>10</sub> y PM<sub>2.5</sub> obtenidos en esta zona industrial fueron  superiores a los reportados en zonas urbanas ubicadas a menos de 100 km viento  arriba de la mina (Rojano <i>et al</i>., 2013; Rojano <i>et al</i>., 2012;  Corpoguajira, 2008); sin embargo, fueron inferiores a los reportados en minas de  carbón a cielo abierto cercanas al Cerrejón (Huertas <i>et al</i>., 2012a;  Angulo <i>et al</i>., 2011) y a los reportados por minas a cielo abierto en  otros lugares del mundo (Song <i>et al</i>., 2014; Aneja <i>et al</i>., 2012;  Chaulya, 2004). Los resultados revelan exposición segura al material particulado  proveniente de las operaciones de explotación de carbón de la comunidad que  habita en esta zona, debido a que presenta niveles inferiores a los estándares  nacionales y de la EPA. Un reciente proyecto de la EPA sugiere nuevo estándar de  24 horas para PM<sub>10</sub> en el rango de 65-85 &#956;g/ m<sup>3</sup> (USEPA,  2010). Aun para los niveles proyectados se estarían cumpliendo estos preceptos.</font></p>     <p align="justify"><font face="Verdana" size="2"><b>Relación y distribución de  masas</b></font></p>     <p align="justify"><font face="Verdana" size="2">La <a href="#tab3">tabla 3</a> presenta la relación  de PM<sub>10</sub>/PST y PM<sub>2.5</sub>/PM<sub>10</sub> en los puntos de  muestreo. La relación PM<sub>10</sub>/PST osciló entre los valores 0,12 a 0,93,  presentando los mayores niveles (0,93 y 0,90) en las estaciones Barrancas y  Patilla. La relación de masa de PM<sub>2.5</sub>/PM<sub>10</sub> estuvo entre  0,06 a 0,78. El promedio de la relación de la masa del material particulado  varió entre 0,41 y 0,71 para PM<sub>10</sub>/PST y entre 0,33 y 0,51 para PM<sub>2.5</sub>/PM<sub>10</sub>.</font></p>     <p align="center"><a name="tab3"> <img border="0" src="/img/fbpe/rfiucv/v30n3/art05tab3.gif" width="560" height="131"></a></p>     
<p align="justify"><font face="Verdana" size="2">Las estaciones Barrancas y  Cuestecita muestran que el 80% y el 67% de sus relaciones de masa PM<sub>10</sub>/PST  están entre 0,50 y 0,90, respectivamente; lo que indica un aporte de fuentes  diferentes a la actividad minera. Este aporte pudiera deberse a emisiones  comunes de centros urbanos tales como el suelo, el pavimento, la manipulación de  materiales, los materiales de construcción y el tráfico vehicular (Pérez- Vidal <i>et al</i>., 2010). Se observa una contribución significativa de las  partículas inhalables en los diferentes sitios de muestreo; esta contribución,  según los promedios, alcanza un porcentaje entre 41% y el 66% del total de PST.  De igual manera, el material fino contribuye entre el 33% al 51% en las  partículas respirables. Estos resultados preocupan debido a que este tamaño de  material particulado ocasiona mayor riesgo sobre la salud. Estas relaciones de  partículas PM<sub>10</sub>/ PST y PM<sub>2.5</sub>/PM<sub>10</sub> son similares  a los reportados por Angulo <i>et al</i>. (2011) y Huertas <i>et al</i>. (2012b)  en zonas de explotación minera similares a las del área de estudio; observándose  menor nivel de concentración en La Mina el Cerrejón que en esos lugares. Esto  puede llevar a la conclusión de que la relación de masas de material particulado  no dependa del nivel de concentración del contaminante, al contrario, puede  deberse a las características de las fuentes que los emiten. La <a href="#fig4">figura 4</a>  presenta las concentraciones y correlaciones de PST y PM<sub>10</sub>, en los  cinco puntos de muestreo. El análisis de los resultados muestra correlación  estadísticamente significativa entre PM<sub>10</sub> y PST, en las estaciones  Barrancas y Provincial (0,66 y 0,73, p &lt; 0,05) y correlación aceptable para las  estaciones Patilla, Cuestecita y Las Casitas (0,59, 0,50 y 0,47, p &lt; 0,05).  Estas relaciones de material particulado son menores comparadas con resultados  de estudios en zonas urbanas de ciudades industrializadas en Colombia (Echaverry  &amp; Maya, 2008; Dongarrá <i>et al</i>., 2010). Puede deberse a la mayor proporción  de material fino (PM<sub>2.5</sub>) proveniente del transporte en estas  ciudades. El de 40% de R2 en la relación PM<sub>10</sub>/PST (<a href="#tab3">tabla 3</a> y <a href="#fig4">figura  4</a>) fue mayor que 0,6. Por lo tanto, los niveles de partículas en la zona minera  del Cerrejón tienen regular correlación.</font></p>     <p align="center"><a name="fig4"> <img border="0" src="/img/fbpe/rfiucv/v30n3/art05fig4.gif" width="562" height="343"></a></p>     
<p align="justify"><font face="Verdana" size="2"><b>Dirección de viento y  concentraciones</b></font></p>     <p align="justify"><font face="Verdana" size="2">La <a href="#tab4">tabla 4</a> presenta el resumen  de los datos meteorológicos en el periodo de muestreo. La velocidad del viento  registró promedio de 3,31 m/s, alcanzando valores máximos cercanos a los 8,20  m/s y periodos de calma (velocidad del viento de 0 m/s) solo un 3,18%. La  dirección predominante fue noreste (NE) con una frecuencia del 86%.</font></p>     ]]></body>
<body><![CDATA[<p align="center"><a name="tab4"> <img border="0" src="/img/fbpe/rfiucv/v30n3/art05tab4.gif" width="554" height="166"></a></p>     
<p align="justify"><font face="Verdana" size="2">La <a href="#fig5">figura 5</a> presenta el  análisis de la dirección del viento y las concentraciones de PM<sub>10</sub> y  PST. Se observa que las estaciones de Barrancas, Provincial y Patilla están  directamente influenciadas por el tajo Patilla (el tajo de mayor dimensión y  actividad en la mina) y el botadero Patilla (zona de almacenaje de material  estéril). La estación Provincial es la más cercana al tajo Patilla (&lt; 5 km) y  está ubicada directamente en la dirección predominante del viento, coincidiendo  con los mayores registros y promedios de estas tres estaciones. La estación Las  Casitas está influenciada por los tajos Oreganal, 100, Comunero, Patilla y Caypa.  Esta estación está a menos de 3 km de los tajos Comunero y 100 y está  directamente en el vector de dirección resultante del viento de 241° (SOO). Esta  estación es la que presenta las mayores concentraciones en este estudio. Entre  esta estación y los tajos mencionados no hay fuentes significativas de emisión  de PM<sub>10</sub> y PST, por lo que se concluye que el aporte potencial de  material particulado en esta estación es producido por las actividades de  extracción de los tajos Comunero y 100. La estación Cuestecita, ubicada viento  arriba de los tajos, mostró los menores niveles de concentraciones de PST, no  así con los niveles de PM<sub>10</sub>. Esto indica que no hay aporte  significativo de operaciones mineras pero sí aporte de actividades cotidianas y  de transporte, por ser una zona urbana de flujo de tráfico liviano y pesado.  Este análisis no describe un fenómeno físico de causa y efecto; por lo tanto, no  se puede utilizar para identificar las fuentes de contaminación influyentes en  las estaciones Barrancas, Provincial, Patilla y Las Casitas; sin embargo, las  principales fuentes de emisión son las de área, que están asociadas con las  actividades de extracción de carbón; luego, se puede inferir una influencia de  los tajos en el aporte de PM<sub>10</sub> y PST.</font></p>     <p align="center"><a name="fig5"> <img border="0" src="/img/fbpe/rfiucv/v30n3/art05fig5.gif" width="565" height="388"></a></p>     
<p align="justify"><font face="Verdana" size="2"><b>CONCLUSIONES</b></font></p>     <p align="justify"><font face="Verdana" size="2">En los cinco sitios de muestreo  los resultados de las concentraciones de PST, PM<sub>10</sub> y PM<sub>2.5</sub>  no excedieron los estándares diarios de la Norma Colombiana y la National  Ambient Air Quality Standards (NAAQS) de los Estados Unidos. El comportamiento  lineal de las relaciones PM<sub>10</sub>/ PST y PM<sub>2.5</sub>/PM<sub>10</sub>  en las estaciones estudiadas en la mina el Cerrejón permite utilizar los valores  de PST para predecir la concentración de PM<sub>10</sub>. Los datos de PM<sub>10</sub>  de áreas de extracción mineras no pueden ser utilizados para predecir con  confianza la concentración de PM<sub>2.5</sub>. Según la dirección predominante  del viento, el aporte de PM<sub>10</sub> y PST en los sitios de monitoreo está  influenciado en forma significativa por las actividades mineras. La contribución  significativa de polvo suspendido proviene de las fuentes de operación mineras.</font></p>     <p align="justify"><font face="Verdana" size="2"><b>AGRADECIMIENTOS</b></font></p>     <p align="justify"><font face="Verdana" size="2">Los autores expresan sus  agradecimientos a la Corporación Autónoma Regional de La Guajira por el  suministro de datos de la zona de estudio; a la Universidad de La Guajira y al  programa “Estrategia de Sostenibilidad 2013- 2014 de la Universidad de Antioquia  (Colombia)” por el financiamiento y apoyo para el desarrollo de este proyecto; a  Carbones del Cerrejón Limited y Colciencias por la financiación del proyecto  “Aplicación de los modelos de receptor en el aporte de fuentes a la  contaminación del aire por material particulado” Código 111552430465l.</font></p>     <p align="justify"><font face="Verdana" size="2"><b>REFERENCIAS</b></font></p>     <!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 1. A</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">neja</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  V., I</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">sherwood</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  A., M</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">organ</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  P. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2012). Characterization of particulate matter (PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span></sub><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">)  related to surface coal mining operations in Appalachia. Atmos Environ. </span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">54; pp. 496-501.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902574&pid=S0798-4065201500030000500001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">2. A</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ngulo, </font></span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">L., H</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">uertas, </font></span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">J., R</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">estrepo, </font></span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">G. </span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">(2011).  Caracterización de partículas suspendidas (PST) y partículas respirables (</span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span></sub><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">)  producidas en áreas de explotación carbonífera a cielo abierto. Información  Tecnológica. 22(4); pp. 23-34.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902575&pid=S0798-4065201500030000500002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 3. B</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">runekreef</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  B. &amp; H</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">olgate</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  S. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2002). Air pollution and health. The Lancet. 360; pp. 1233-1242.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902576&pid=S0798-4065201500030000500003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">4. CARBONES DEL  CERREJÓN LIMITED. Cerrejón. Departamento Gestión Ambiental. (2013). Modelación  de Calidad del Aire. Plan Minero. Albania. 35 p.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902577&pid=S0798-4065201500030000500004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">5. CENTRAL  MINING RESEARCH </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> INSTITUTE. (CMRI). (1999). Annual environmental monitoring report for Lakhanpur  area. GC/EMG/94/98-99. Report. Dhanbad. 280 p.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902578&pid=S0798-4065201500030000500005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 6. C</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">haulya</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  S. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2004). Assessment and management of air quality for an opencast coal mining  area. J Environ Manage. </span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">70; pp. 1-14.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902579&pid=S0798-4065201500030000500006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">7. CORPORACIÓN  AUTÓNOMA REGIONAL DE LA GUAJIRA (CORPOGUAJIRA). (2008). Oficina de Monitoreo y  Control. Estudio de emisiones atmosféricas para el municipio Riohacha en los  contaminantes partículas suspendidas totales (PST) y menores de 10 micras </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span></sub><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">.  Informe. Riohacha, 120 p.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902580&pid=S0798-4065201500030000500007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 8. D</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ongarrá</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  G.; M</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">anno</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  E., V</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">arrica</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  D., L</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ombardo</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  M. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2010). Study on ambient concentrations of PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span></sub><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">,  PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">-</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">2.5</font></span></sub><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">,  PM</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2"><sub>2.5</sub> </font></span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">and  gaseous pollutants. Trace elements and chemical speciation of atmospheric  particulates. Atmos Environ. 44; pp. 5244-5257.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902581&pid=S0798-4065201500030000500008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 9. D</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ostal</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  M., P</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">astorkova</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  A., R</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ychlik</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  S., R</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ychlikova</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  E., S</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">vecova</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  V., S</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">challerova</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  E., S</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ram</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  R. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2013). Comparison of child morbidity in regions of Ostrava, Czech Republic,  with different degrees of pollution: a retrospective cohort study. Environmental  Health. </span> <span lang="FR" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">12;  pp. 2-11.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902582&pid=S0798-4065201500030000500009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">10. E</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">cheverri</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  C., M</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">aya</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  G. </span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2008). Relación entre las partículas finas (</span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">PM</span><font size="2"><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><sub>2.5</sub></span></font><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">)  y respirables (</span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span></sub><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">)  en la ciudad de Medellín. Revista Ingenierías (Universidad de Medellín) 7; pp.  23-42.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902583&pid=S0798-4065201500030000500010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">11. G</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">alvis, </font></span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">B., R</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ojas, </font></span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">N. </span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">(2006). Relación  entre </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">PM</span><font size="2"><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><sub>2.5</sub></span></font><span style="font-family: TimesNewRomanPSMT"><font size="2"> </font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">y </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span></sub><span style="font-family: TimesNewRomanPSMT"><font size="2"> </font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">en  la ciudad de Bogotá. ACTA NOVA. 3(2); pp. 336-353.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902584&pid=S0798-4065201500030000500011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 12. G</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">hose</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  M., M</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ajee</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  J. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2000). Assessment of dust generation due to opencast coal mining-an Indian case  study. Environ Monit Assess. 61; pp. 257-263.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902585&pid=S0798-4065201500030000500012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 13. G</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">hose</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  M., M</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ajee</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  J. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2007). Characteristics of hazardous airborne dust around an Indian surface coal  mining area. Environ Monit Assess. </span> <span lang="FR" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">130;  pp. 17-25.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902586&pid=S0798-4065201500030000500013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 14. H</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">endryx</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  M., Z</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ullig</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  K. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2009). Higher coronary heart disease and heart attack morbidity in Appalachian  coal mining regions. Prev Med. 49; pp. 355-359.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902587&pid=S0798-4065201500030000500014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 15. H</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">oek</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  G., K</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">rishnan</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  R., B</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">eelen</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  R., P</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">eters</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  A., O</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">stro</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  B., B</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">runekreef</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  B., K</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">aufman</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  J. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2013). Long-term air pollution exposure and cardio- respiratory mortality: a  review. Environmental Health. 12; pp. 2-15.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902588&pid=S0798-4065201500030000500015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">16. H</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">uertas</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  J., C</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">amacho</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  D., H</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">uertas</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  M. </span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2012a). </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> Standardized emissions inventory methodology for open pit mining areas. </span> <span lang="FR" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> Environ Sci Pollut R. 19; pp. 784-2794.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902589&pid=S0798-4065201500030000500016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">17. H</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">uertas</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  J., H</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">uertas</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  M., S</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">olís</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  D. </span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2012b). </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> Characterization of airborne particles in an open pit mining region. Sci Total  Environ. </span> <span lang="FR" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">423;  pp. 39-46.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902590&pid=S0798-4065201500030000500017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 18. L</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">iu</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  Y., C</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">hen</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  R., S</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">hen</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  X., M</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ao</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  X. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2004). Wintertime indoor air levels of PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span></sub><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">,  PM</span><font size="2"><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><sub>2.5</sub></span></font><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2"> </font></span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">and  PM1 at public places and their contributions to TSP. Environment International.  30(2): pp. 189-197.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902591&pid=S0798-4065201500030000500018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">19. MINISTERIO  DE AMBIENTE Y DESARROLLO SOSTENIBLE. MAVDT. (2010). Por la cual se establece la  Norma de Calidad del Aire o Nivel de Inmisión, para todo el territorio nacional  en condiciones de referencia. Diario Oficial 47.672. Resolución 0610 de 2010.  Colombia. 17 p.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902592&pid=S0798-4065201500030000500019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">20. MINISTERIO  DE MINAS Y ENERGÍAS. Colombia. Unidad de Planeación Minero Energética. UPME  (2006). Plan Nacional para el desarrollo minero. Visión año 2019. Plan Nacional.  Bogotá. </span> <span lang="PT-BR" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">125  p.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902593&pid=S0798-4065201500030000500020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="PT-BR" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 21. M</span><span lang="PT-BR" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ugica</font></span><span lang="PT-BR" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  V., M</span><span lang="PT-BR" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">aubert</font></span><span lang="PT-BR" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  M., T</span><span lang="PT-BR" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">orres</font></span><span lang="PT-BR" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  M., M</span><span lang="PT-BR" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">uñoz</font></span><span lang="PT-BR" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  J., R</span><span lang="PT-BR" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ico</font></span><span lang="PT-BR" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  E. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2002). Temporal and spatial variations of metal content in TSP and PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span></sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2"> </font></span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">in  Mexico City during 1996-1998. J Aerosol Sci. 33; pp. 91-102.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902594&pid=S0798-4065201500030000500021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 22. M</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">uránszky</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  G., Ó</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">vári</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  M., V</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">irág</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  I., C</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">siba</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  P., D</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">obai</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  R., G</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">yula</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  Z. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2011). Chemical characterization of PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span></sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2"> </font></span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> fractions of urban aerosol. Microchem J. 98; pp. 1-10.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902595&pid=S0798-4065201500030000500022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">23. P</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">érez</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">-V</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">idal</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  H., L</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">unagómez</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">-R</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ocha</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  M., A</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">costa</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">-P</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">érez, </font></span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">L. </span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">(2010). Análisis  de partículas suspendidas totales (PST) y partículas fracción respirable (</span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span></sub><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">),  en Cunduacán, Tabasco. Universidad y Ciencia, 26(2): 151-162.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902596&pid=S0798-4065201500030000500023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 24. P</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ope</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  C., D</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ockery</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  D. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2006). Health effects of fine particulate air pollution: lines that connect. J  Air Waste Manage. 56; pp. 1368-1380.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902597&pid=S0798-4065201500030000500024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 25. P</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ope</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  C., E</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">zzati</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  M., D</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ockery</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  D. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2009). Fine-Particulate Air Pollution and Life Expectancy in the United States.  New Engl J Med. 360; pp. 376-386.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902598&pid=S0798-4065201500030000500025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">26. R</span><font size="2"><span style="font-family: TimesNewRomanPSMT-SC700">ojano, </span></font> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">R., P</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">érez, </font></span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">J., F</span><font size="2"><span style="font-family: TimesNewRomanPSMT-SC700">reyle, </span></font> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">E. </span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">(2012). </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> Effect of relative humidity in determining PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span></sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2"> </font></span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> using a DataRam 4 in coastal region of Colombia. Rev. Téc. Ing. </span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">Univ. Zulia. 35  (2); pp. 1- 9.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902599&pid=S0798-4065201500030000500026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">27. R</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ojano</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  R., A</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ngulo</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  L., R</span><span style="font-family: TimesNewRomanPSMT-SC700"><font size="2">estrepo</font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  G. </span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2013). Niveles de partículas suspendidas totales (PST), </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span></sub><span style="font-family: TimesNewRomanPSMT"><font size="2"> </font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">y </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">PM</span><font size="2"><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><sub>2.5</sub></span></font><span style="font-family: TimesNewRomanPSMT"><font size="2"> </font></span><span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">y  su relación en lugares públicos de la ciudad Riohacha, Caribe Colombiano.  Información Tecnológica. 24; pp. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> 37-46.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902600&pid=S0798-4065201500030000500027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 28. S</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ong</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  X., S</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">hao</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  L., Z</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">heng</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  Q., Y</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ang, </font></span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> S. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2014). Mineralogical and geochemical composition of particulate matter (PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span></sub><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">)  in coal and non-coal industrial cities of Henan Province, North China. Atmos  Res. 143; pp. 462-472.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902601&pid=S0798-4065201500030000500028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">29.  UNITED STATE ENVIRONMENTAL PROTECTION AGENCY. USEPA. (2010). Policy Assessment  for the Review of the Particulate Matter National Ambient Air Quality Standards,  Second External Review Draft. </span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">Recuperado el 29  de noviembre de 2013, de <a href="http://www.epa.gov/ttn/naaqs/standards/pm/data/20100630seconddraftpmpa.pdf"> http://www.epa.gov/ttn/naaqs/standards/pm/data/20100630seconddraftpmpa.pdf</a></span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902602&pid=S0798-4065201500030000500029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">30.  UNITED STATES ENVIRONMENTAL PROTECTION AGENCY. EPA. (1980). Reference method for  the determination of suspended particulate matter in the atmosphere (high-volume  method). Appendix B to part 50. Quality Assurance Division. Research Triangle  Park, NC 27711, pp. 33-45.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902603&pid=S0798-4065201500030000500030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">31.  UNITED STATES ENVIRONMENTAL PROTECTION AGENCY. EPA. (1997). Reference method for  the determination of particulate matter as PM</span><sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2">10</font></span></sub><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2"> </font></span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">in  the atmosphere. Appendix J to part 50. Quality Assurance Division. Research  Triangle Park, NC 27711, pp. 73-78.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902604&pid=S0798-4065201500030000500031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">32.  UNITED STATES ENVIRONMENTAL PROTECTION AGENCY. USEPA. (1988). Control of open  fugitive dust sources. Office of Air Quality Planning and Standards,  EPA-450/3-88-008. Report. North Carolina. 349 p.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902605&pid=S0798-4065201500030000500032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">33.  UNITED STATES ENVIRONMENTAL PROTECTION AGENCY. USEPA. (1998). Emission Factors  for AP-42. Compilation of Air Pollutant Emission Factors. Section 11.9, Western  Surface Coal Mining Fifth Edition, Project N°4604-02. Research Triangle Park,  North Carolina, 350p.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902606&pid=S0798-4065201500030000500033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> 34. V</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">an</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">-S</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">teenis</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  D. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2008). Coal open casting and health. </span> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">Recuperado el 12  de enero de 2014, de <a style="color: blue; text-decoration: underline; text-underline: single" href="http://www.countrydoctor.co.uk/precis/precis%20-%20Opencasting%20coal%20and%20health.htm"> http://www.countrydoctor.co.uk/precis/precis%20-%20Opencasting%20coal%20and%20health.htm</a></span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902607&pid=S0798-4065201500030000500034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="text-autospace: none" align="justify"><font face="Verdana"> <span style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">35. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> Z</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">hang</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  N., C</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">ao</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  J., X</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">u</font></span><span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700">,  H., Z</span><span lang="EN-US" style="font-family: TimesNewRomanPSMT-SC700"><font size="2">hu, </font></span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT-SC700"> C. </span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT"> (2013). Elemental compositions of PM</span><font size="2"><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><sub>2.5</sub></span></font><span lang="EN-US" style="font-family: TimesNewRomanPSMT"><font size="2"> </font></span> <span lang="EN-US" style="font-size: 10.0pt; font-family: TimesNewRomanPSMT">and  TSP in Lijiang, southeastern edge of Tibetan Plateau during pre-monsoon period.  Particuology. 11; pp. 63-69.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1902608&pid=S0798-4065201500030000500035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body>
<back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aneja]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Isherwood]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Morgan]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Characterization of particulate matter (PM10) related to surface coal mining operations in Appalachia]]></article-title>
<source><![CDATA[Atmos Environ]]></source>
<year>2012</year>
<volume>54</volume>
<page-range>496-501</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Angulo]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Huertas]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Restrepo]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Caracterización de partículas suspendidas (PST) y partículas respirables (PM10) producidas en áreas de explotación carbonífera a cielo abierto]]></article-title>
<source><![CDATA[Información Tecnológica.]]></source>
<year>2011</year>
<volume>22</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>23-34</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brunekreef]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Holgate]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Air pollution and health]]></article-title>
<source><![CDATA[The Lancet]]></source>
<year>2002</year>
<volume>360</volume>
<page-range>1233-1242</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="">
<collab>CARBONES DEL CERREJÓN LIMITED^dDepartamento Gestión Ambiental</collab>
<source><![CDATA[Modelación de Calidad del Aire: Plan Minero]]></source>
<year>2013</year>
<page-range>35</page-range><publisher-loc><![CDATA[Albania ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="">
<collab>CENTRAL MINING RESEARCH INSTITUTE. (CMRI)</collab>
<source><![CDATA[Annual environmental monitoring report for Lakhanpur area]]></source>
<year>1999</year>
<page-range>280</page-range><publisher-loc><![CDATA[Dhanbad ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chaulya]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Assessment and management of air quality for an opencast coal mining area]]></article-title>
<source><![CDATA[J Environ Manage.]]></source>
<year>2004</year>
<volume>70</volume>
<page-range>1-14</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="">
<collab>CORPORACIÓN AUTÓNOMA REGIONAL DE LA GUAJIRA (CORPOGUAJIRA)</collab>
<source><![CDATA[Oficina de Monitoreo y Control. Estudio de emisiones atmosféricas para el municipio Riohacha en los contaminantes partículas suspendidas totales (PST) y menores de 10 micras PM10: Informe]]></source>
<year>2008</year>
<page-range>120</page-range><publisher-loc><![CDATA[Riohacha ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dongarrá]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Manno]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Varrica]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Lombardo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Study on ambient concentrations of PM10, PM10-2.5, PM2.5 and gaseous pollutants: Trace elements and chemical speciation of atmospheric particulates]]></article-title>
<source><![CDATA[Atmos Environ.]]></source>
<year>2010</year>
<volume>44</volume>
<page-range>5244-5257</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dostal]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Pastorkova]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Rychlik]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Rychlikova]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Svecova]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Schallerova]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Sram]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of child morbidity in regions of Ostrava, Czech Republic, with different degrees of pollution: a retrospective cohort study]]></article-title>
<source><![CDATA[Environmental Health]]></source>
<year>2013</year>
<volume>12</volume>
<page-range>2-11</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Echeverri]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Maya]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Relación entre las partículas finas (PM2.5) y respirables (PM10) en la ciudad de Medellín]]></article-title>
<source><![CDATA[Revista Ingenierías (Universidad de Medellín)]]></source>
<year>2008</year>
<volume>7</volume>
<page-range>23-42</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Galvis]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Rojas]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Relación entre PM2.5 y PM10 en la ciudad de Bogotá]]></article-title>
<source><![CDATA[ACTA NOVA.]]></source>
<year>2006</year>
<volume>3</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>336-353</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ghose]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Majee]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Assessment of dust generation due to opencast coal mining-an Indian case study]]></article-title>
<source><![CDATA[Environ Monit Assess.]]></source>
<year>2000</year>
<volume>61</volume>
<page-range>257-263</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ghose]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Majee]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Characteristics of hazardous airborne dust around an Indian surface coal mining area]]></article-title>
<source><![CDATA[Environ Monit Assess.]]></source>
<year>2007</year>
<volume>130</volume>
<page-range>17-25</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hendryx]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Zullig]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Higher coronary heart disease and heart attack morbidity in Appalachian coal mining regions]]></article-title>
<source><![CDATA[Prev Med.]]></source>
<year>2009</year>
<volume>49</volume>
<page-range>355-359</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hoek]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Krishnan]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Beelen]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Peters]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Ostro]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Brunekreef]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Kaufman]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Long-term air pollution exposure and cardio- respiratory mortality: a review]]></article-title>
<source><![CDATA[Environmental Health.]]></source>
<year>2013</year>
<volume>12</volume>
<page-range>2-15</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Huertas]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Camacho]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Huertas]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Standardized emissions inventory methodology for open pit mining areas]]></article-title>
<source><![CDATA[Environ Sci Pollut R.]]></source>
<year>2012</year>
<month>a</month>
<volume>19</volume>
<page-range>784-2794</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Huertas]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Huertas]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Solís]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Characterization of airborne particles in an open pit mining region]]></article-title>
<source><![CDATA[Sci Total Environ.]]></source>
<year>2012</year>
<month>b</month>
<volume>423</volume>
<page-range>39-46</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Shen]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Mao]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Wintertime indoor air levels of PM10, PM2.5 and PM1 at public places and their contributions to TSP]]></article-title>
<source><![CDATA[Environment International.]]></source>
<year>2004</year>
<volume>30</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>189-197</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="">
<collab>MINISTERIO DE AMBIENTE Y DESARROLLO SOSTENIBLE. MAVDT</collab>
<source><![CDATA[Por la cual se establece la Norma de Calidad del Aire o Nivel de Inmisión, para todo el territorio nacional en condiciones de referencia]]></source>
<year>2010</year>
<page-range>17</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="">
<collab>MINISTERIO DE MINAS Y ENERGÍAS^dUnidad de Planeación Minero Energética. UPME</collab>
<source><![CDATA[Plan Nacional para el desarrollo minero: Visión año 2019. Plan Nacional]]></source>
<year>2006</year>
<page-range>125</page-range><publisher-loc><![CDATA[Bogotá ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mugica]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Maubert]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Torres]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Muñoz]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Rico]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Temporal and spatial variations of metal content in TSP and PM10 in Mexico City during 1996-1998]]></article-title>
<source><![CDATA[J Aerosol Sci.]]></source>
<year>2002</year>
<volume>33</volume>
<page-range>91-102</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Muránszky]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Óvári]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Virág]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Csiba]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Dobai]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Gyula]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Chemical characterization of PM10 fractions of urban aerosol]]></article-title>
<source><![CDATA[Microchem J.]]></source>
<year>2011</year>
<volume>98</volume>
<page-range>1-10</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pérez-Vidal]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Lunagómez-Rocha]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Acosta-Pérez]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Análisis de partículas suspendidas totales (PST) y partículas fracción respirable (PM10), en Cunduacán, Tabasco]]></article-title>
<source><![CDATA[Universidad y Ciencia]]></source>
<year>2010</year>
<volume>26</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>151-162</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pope]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Dockery]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Health effects of fine particulate air pollution: lines that connect]]></article-title>
<source><![CDATA[J Air Waste Manage.]]></source>
<year>2006</year>
<volume>56</volume>
<page-range>1368-1380</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pope]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Ezzati]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Dockery]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fine-Particulate Air Pollution and Life Expectancy in the United States]]></article-title>
<source><![CDATA[New Engl J Med.]]></source>
<year>2009</year>
<volume>360</volume>
<page-range>376-386</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rojano]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Freyle]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of relative humidity in determining PM10 using a DataRam 4 in coastal region of Colombia]]></article-title>
<source><![CDATA[Rev. Téc. Ing. Univ. Zulia. 35]]></source>
<year>2012</year>
<volume>(2)</volume>
<page-range>1- 9</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rojano]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Angulo]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Restrepo]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Niveles de partículas suspendidas totales (PST), PM10 y PM2.5 y su relación en lugares públicos de la ciudad Riohacha, Caribe Colombiano]]></article-title>
<source><![CDATA[Información Tecnológica.]]></source>
<year>2013</year>
<volume>24</volume>
<page-range>37-46</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Song]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Shao]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Zheng]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mineralogical and geochemical composition of particulate matter (PM10) in coal and non-coal industrial cities of Henan Province, North China]]></article-title>
<source><![CDATA[Atmos Res.]]></source>
<year>2014</year>
<volume>143</volume>
<page-range>462-472</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="">
<collab>UNITED STATE ENVIRONMENTAL PROTECTION AGENCY. USEPA</collab>
<source><![CDATA[Policy Assessment for the Review of the Particulate Matter National Ambient Air Quality Standards, Second External Review Draft]]></source>
<year>2010</year>
</nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="">
<collab>UNITED STATES ENVIRONMENTAL PROTECTION AGENCY. EPA</collab>
<source><![CDATA[Reference method for the determination of suspended particulate matter in the atmosphere (high-volume method)]]></source>
<year>1980</year>
<page-range>33-45</page-range><publisher-loc><![CDATA[Research Triangle Park^eNC NC]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="">
<collab>UNITED STATES ENVIRONMENTAL PROTECTION AGENCY. EPA</collab>
<source><![CDATA[Reference method for the determination of particulate matter as PM10 in the atmosphere]]></source>
<year>1997</year>
<page-range>73-78</page-range><publisher-loc><![CDATA[Research Triangle Park^eNC NC]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="">
<collab>UNITED STATES ENVIRONMENTAL PROTECTION AGENCY. USEPA</collab>
<source><![CDATA[Control of open fugitive dust sources]]></source>
<year>1988</year>
<page-range>349</page-range><publisher-loc><![CDATA[^eNorth Carolina North Carolina]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="">
<collab>UNITED STATES ENVIRONMENTAL PROTECTION AGENCY. USEPA</collab>
<source><![CDATA[Emission Factors for AP-42. Compilation of Air Pollutant Emission Factors]]></source>
<year>1998</year>
<edition>Fifth</edition>
<page-range>350</page-range><publisher-loc><![CDATA[Research Triangle Park^eNorth Carolina North Carolina]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Van-Steenis]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<source><![CDATA[Coal open casting and health]]></source>
<year>2008</year>
</nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Cao]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Xu]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Zhu]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Elemental compositions of PM2.5 and TSP in Lijiang, southeastern edge of Tibetan Plateau during pre-monsoon period]]></article-title>
<source><![CDATA[Particuology.]]></source>
<year>2013</year>
<volume>11</volume>
<page-range>63-69</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
