<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1315-2556</journal-id>
<journal-title><![CDATA[Revista de la Sociedad Venezolana de Microbiología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Soc. Ven. Microbiol.]]></abbrev-journal-title>
<issn>1315-2556</issn>
<publisher>
<publisher-name><![CDATA[Organo Oficial de la Sociedad Venezolana de Microbiología.]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1315-25562010000100008</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Asas metálicas calibradas para microbiólogos: Una alternativa de fabricación nacional]]></article-title>
<article-title xml:lang="en"><![CDATA[Calibrated metallic loops for microbiologists: A nationally manufactured alternative]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Herrera]]></surname>
<given-names><![CDATA[Dubraska]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[López]]></surname>
<given-names><![CDATA[Patricia]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Duque Rivera]]></surname>
<given-names><![CDATA[José Luis]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pérez Ybarra]]></surname>
<given-names><![CDATA[Luis]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Golding]]></surname>
<given-names><![CDATA[Rafael]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[Clara]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de Carabobo Facultad de Ciencias de la Salud Departamento de Ciencia Básicas]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Venezuela</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad Central de Venezuela Facultad de Ciencias Escuela de Química]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Venezuela</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2010</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2010</year>
</pub-date>
<volume>30</volume>
<numero>1</numero>
<fpage>37</fpage>
<lpage>42</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_arttext&amp;pid=S1315-25562010000100008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_abstract&amp;pid=S1315-25562010000100008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://ve.scielo.org/scielo.php?script=sci_pdf&amp;pid=S1315-25562010000100008&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Las asas calibradas para la cuantificación de unidades formadoras de colonias bacterianas transfieren un volumen de muestra “exactamente conocido” y han sido herramientas de gran importancia para laboratorios de control de calidad, investigación y clínico. Las asas que se comercializan en el país son importadas y mayoritariamente de aleaciones de níquel-cromo. Es por ello que surge la necesidad de buscar internamente alternativas de bajo costo. En este trabajo se propuso la fabricación de asas con alambres comerciales de níquel-cromo equivalentes a las asas de platino y níquel-cromo comerciales, a un costo inferior. Las asas fueron comparadas según su desempeño y apariencia. Todas las asas fueron calibradas empleando dos métodos (gravimétrico y colorimétrico) con ángulos de carga de 45º y 90°. Se empleó un diseño experimental con arreglo factorial de tratamiento 2³ (método de calibración-tipo de asa-ángulo de carga, con 4 repeticiones). Se realizaron análisis de varianza de 672 datos, comparación de medias (prueba de Tukey) y se calcularon los intervalos de confianza de Bonferroni de las desviaciones estándar. Se demostró que las asas artesanales emulan a las comerciales, representando una alternativa nacional de bajo costo para la obtención de estos instrumentos.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Calibrated metallic loops for the quantification of bacterial colony forming units transfer an “exactly known” sample volume and have been extremely important tools for quality control, research and clinical laboratories. The loops marketed in our country are imported and mostly made of nickel-chrome alloy. This has created the need for searching for low cost national alternatives. In this work we propose the manufacture of these loops with commercial nickel-chrome wire equivalent to the commercial platinum and nickel-chrome loops, at lower costs. The loops were comparable in performance and appearance. All the loops were calibrated using two methods (gravimetric and colorimetric) with 45º and 90º charge angles. An experimental design with factorial treatment arrangement 2³ (calibration method-loop type-charge angle with 4 repetitions) was used. A 672 data variance analysis and comparison of means (Tukey’s test) were carried out, and Bonferroni’s confidence intervals of the standard deviations were calculated. It was demonstrated that the artisan loops emulated the commercial ones, representing a low cost national alternative for obtaining these instruments.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[asas calibradas]]></kwd>
<kwd lng="es"><![CDATA[asas de níquel-cromo]]></kwd>
<kwd lng="en"><![CDATA[calibrated loops]]></kwd>
<kwd lng="en"><![CDATA[nickel-chrome loops]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="center" style="text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span lang="ES-TRAD" style="line-height: 120%; color: black; font-weight: 700"> Asas metálicas calibradas para microbiólogos: </span> <span style="line-height: 120%; color: black; font-weight: 700">U</span><span lang="ES-TRAD" style="line-height: 120%; color: black; font-weight: 700">na  alternativa de fabricación nacional</span></font></p>     <p align="center" style="text-autospace: none; vertical-align: middle"> <font face="Verdana" size="2"> <span lang="ES-TRAD" style="line-height: 200%; color: black; font-weight: 700"> Dubraska Herrera<sup>a</sup>, Patricia López<sup>a</sup>, José Luis Duque Rivera<sup>a</sup>,  Luis Pérez Ybarra<sup>a</sup>, Rafael Golding<sup>b</sup>, Clara Hernández<sup>a,</sup>*</span></font></p>     <p align="center" style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><sup> <span lang="ES-TRAD" style="line-height: 120%; color: black"><font size="2">a</font></span></sup><font size="2"><span style="line-height: 120%; color: black"> </span><span lang="ES-TRAD" style="line-height: 120%; color: black">Departamento  de Ciencia Básicas, Escuela de Bioanálisis, Facultad de Ciencias de la Salud,  Universidad de </span></font></font><font face="Verdana" size="2"> <span lang="ES-TRAD" style="line-height: 120%; color: black">Carabobo, Sede  Aragua.</span><span style="line-height: 120%; color: black"> Venezuela</span></font></p>     <p align="center" style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana" size="2"> <sup><span lang="ES-TRAD" style="line-height: 120%; color: black">b</span><span style="line-height: 120%; color: black"> </span></sup> <span lang="ES-TRAD" style="line-height: 120%; color: black">Escuela de Química, Facultad de Ciencias, Universidad  Central de Venezuela.</span><span style="line-height: 120%; color: black">  Venezuela</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana" size="2"> <span lang="ES-TRAD" style="line-height: 120%; color: black">* Correspondencia:</span></font><font face="Verdana"><i><font size="2"><span style="line-height: 120%; color: black"> </span><span lang="ES-TRAD" style="line-height: 120%; color: black">E-mail</span></font></i><font size="2"><span lang="ES-TRAD" style="line-height: 120%; color: black">: <a href="mailto:cmhm3105@yahoo.com">cmhm3105@yahoo.com</a></span><span style="line-height: 120%; color: black"> </span></font></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><b><span lang="ES-TRAD" style="color: black"> <font size="2">Resumen:</font></span></b></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><span style="color: black"><font size="2">Las asas  calibradas para la cuantificación de unidades formadoras de colonias bacterianas  transfieren un volumen de muestra “exactamente conocido” y han sido herramientas  de gran importancia para laboratorios de control de calidad, investigación y  clínico. Las asas que se comercializan en el país son importadas y  mayoritariamente de aleaciones de níquel-cromo. Es por ello que surge la  necesidad de buscar internamente alternativas de bajo costo. En este trabajo se  propuso la fabricación de asas con alambres comerciales de níquel-cromo  equivalentes a las asas de platino y níquel-cromo comerciales, a un costo  inferior. Las asas fueron comparadas según su desempeño y apariencia. Todas las  asas fueron calibradas empleando dos métodos (gravimétrico y colorimétrico) con  ángulos de carga de 45º y 90°. Se empleó un diseño experimental con arreglo  factorial de tratamiento 2<sup>3</sup> (método de calibración-tipo de asa-ángulo  de carga, con 4 repeticiones). Se realizaron análisis de varianza de 672 datos,  comparación de medias (prueba de Tukey) y se calcularon los intervalos de  confianza de Bonferroni de las desviaciones estándar. Se demostró que las asas  artesanales emulan a las comerciales, representando una alternativa nacional de  bajo costo para la obtención de estos instrumentos.</font></span></font></p>     <p style="text-autospace: none; vertical-align: middle" align="justify"> <font face="Verdana"><b><span lang="ES-TRAD" style="color: black"> <font size="2">Palabras clave</font></span></b><span lang="ES-TRAD" style="color: black"><font size="2"><b>:</b> </font></span><span style="color: black"><font size="2">asas calibradas, asas de  níquel-cromo</font></span></font></p>     <p align="center" style="text-autospace: none; vertical-align: middle"> <font face="Verdana" size="2"> <span lang="EN-US" style="line-height: 120%; color: black; font-weight: 700"> Calibrated metallic loops for microbiologists: A nationally manufactured  alternative</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><b><span lang="EN-US" style="color: black"><font size="2"> Abstract:</font></span></b></font></p>     ]]></body>
<body><![CDATA[<p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><span lang="EN-US" style="color: black"><font size="2"> Calibrated metallic loops for the quantification of bacterial colony forming  units transfer an “exactly known” sample volume and have been extremely  important tools for quality control, research and clinical laboratories. The  loops marketed in our country are imported and mostly made of nickel-chrome  alloy. This has created the need for searching for low cost national  alternatives. In this work we propose the manufacture of these loops with  commercial nickel-chrome wire equivalent to the commercial platinum and  nickel-chrome loops, at lower costs. The loops were comparable in performance  and appearance. All the loops were calibrated using two methods (gravimetric and  colorimetric) with 45<sup>o</sup> and 90<sup>o</sup> charge angles. An  experimental design with factorial treatment arrangement 2<sup>3</sup>  (calibration method-loop type-charge angle with 4 repetitions) was used. A 672  data variance analysis and comparison of means (Tukey’s test) were carried out,  and Bonferroni’s confidence intervals of the standard deviations were  calculated. It was demonstrated that the artisan loops emulated the commercial  ones, representing a low cost national alternative for obtaining these  instruments.</font></span></font></p>     <p style="text-autospace: none; vertical-align: middle" align="justify"> <font face="Verdana"><b><span lang="EN-US" style="color: black"><font size="2"> Keywords: </font></span></b><span lang="EN-US" style="color: black"> <font size="2">calibrated loops, nickel-chrome loops</font></span></font></p>     <p align="center" style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana" size="2"> <span lang="ES-TRAD" style="line-height: 120%; color: black">Recibido 23 de  noviembre de 2009; aceptado 7 de junio de 2010</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><b> <span lang="ES-TRAD" style="font-size: 10.0pt; line-height: 150%; color: black"> Introducción</span></b></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Para la  cuantificación de bacterias en suspensiones de fluidos biológicos, las asas  calibradas, tanto metálicas como plásticas, han sido herramientas  imprescindibles en el laboratorio clínico. Entre las ventajas de las asas  calibradas de metal con respecto a las plásticas desechables, se tiene que son  más eficientes en la siembra de cultivos, son de fácil manipulación, y además  permiten realizar contajes semi-cuantitativos de distintas bacterias con mayor  certeza. La principal desventaja radica en su alto costo, ya que las asas son  importadas y fabricadas con metales nobles, lo que dificulta que muchos  laboratorios de bajo presupuesto puedan adquirirlas.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">La primera asa  metálica calibrada de las que se tiene conocimiento fue descrita en 1928 [1].  Son ideales para el contaje cuantitativo de colonias porque permiten la  reexaminación bacteriológica [2-5]. Específicamente, las asas de platino de 1 y  10 µL son ampliamente utilizadas en la determinación de unidades formadoras de  colonias (UFC) en distintos fluidos biológicos, tanto en laboratorios clínicos y  docentes como de investigación. También se emplean para cuantificar micoplasmas  y permiten realizar la siembra de diversos microorganismos [1].</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Las asas están  diseñadas para transferir un volumen de muestra “exactamente conocido” y sigue  siendo el método más recomendado por muchos laboratorios de microbiología [6].  La precisión y exactitud de estos instrumentos debe ser garantizada por el  proveedor, puesto que en el caso de una transferencia inadecuada de la muestra,  el resultado de un análisis reportado por el especialista podría conducir a  interpretaciones erróneas por parte del médico tratante, generando un  diagnóstico inapropiado.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Existen dos  métodos convencionales de estandarización de asas para la transferencia de  fluidos: el colorimétrico, método indirecto basado en la ley de Lambert-Beer  para asas de volúmenes pequeños, y el gravimétrico, método directo basado en  medidas de masa y recomendado para asas de volúmenes de 10 µL en adelante [7].  El método colorimétrico consiste en hacer pasar una radiación electromagnética  de la región visible por una solución de concentración conocida. La absorbancia,  una medida de la absorción de luz que experimenta una solución coloreada es  directamente proporcional a la concentración de la solución (Ley de  Lambert-Beer) [8]. Un volumen conocido de agua, contenido en una cubeta  fotométrica, es teñido con la solución que muestrea el asa en estudio. Mediante  una curva de calibración preparada con el mismo colorante se puede determinar la  cantidad de colorante inoculada por el asa en la cubeta, la cual depende del  volumen real muestreado por el asa.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Por otra parte,  el método gravimétrico consiste en la transferencia de un número de alícuotas de  una muestra (agua destilada por ejemplo) a un papel de filtro colocado en el  platillo de una balanza de alta precisión [1, 3, 5]. Conocidas la densidad del  líquido transportado, la temperatura y la presión atmosférica, es posible  calcular el volumen cargado por el asa.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">La  Administración de Alimentos y Drogas de los Estados Unidos (Food and Drug  Administration, FDA) ha certificado un método de control de calidad para asas de  metal un tanto diferente a los anteriormente discutidos. Se ha empleado este  método para estudio de productos lácteos utilizando asas calibradas de  níquel-cromo (diámetro del alambre 0,20±0,06 mm) de 0,001 mL. El método requiere  una barra de metal de dos calibres. En un extremo 3,988 mm y en el otro 4,039 mm.  Simplemente se intenta desplazar el aro a calibrar por ambos extremos de la  barra. Si el asa está calibrada (forma y volumen correctos) debe solamente  entrar por el extremo de menor calibre, si el asa pasa a través del extremo de  mayor calibre, ésta requerirá ajustes. El procedimiento es rápido con un alto  grado de exactitud, el error del método no es mayor al 1% [9], superando  ostensiblemente a los métodos colorimétricos cuyo errores pueden ser de hasta  20%. </span></font></p>     ]]></body>
<body><![CDATA[<p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Las asas para  la transferencia de fluidos, en cualquiera de sus presentaciones, deben ser  calibradas dada la necesidad de conocer con precisión y exactitud los volúmenes  de muestra que inoculan, y deben conseguirse en estado estéril, o ser  esterilizables por métodos convencionales sin que se comprometa su desempeño.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">El platino,  aleado con otros metales como el rodio, ha sido por excelencia el metal más  empleado en la fabricación de asas. El metal puede ser esterilizado a la llama,  pero por ser muy blando y deformable, suele perderse la calibración con  facilidad por cambios en la forma del aro.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">En los  laboratorios de docencia el uso de asas de platino muchas veces es de alcance  limitado debido a los altos costos. Esto ha hecho popular el empleo de alambres  de níquel-cromo (Ni-Cr), los cuales son aceptablemente buenos para la tarea. En  consecuencia, una alternativa sencilla, económica e igualmente eficaz es la  fabricación de asas con alambres comerciales de Ni-Cr de menor costo, mayor  dureza y menos deformables; tales asas pueden ser manipuladas fácilmente,  esterilizadas a la llama y empleadas en las mismas tareas en las que se utilizan  las asas de platino de soporte duro. Por todo lo expuesto, el presente trabajo  propone la fabricación de asas de metal, para la siembra de cultivos biológicos,  con alambres de Ni-Cr empleando una metodología propia y un método de  calibración rápido.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><b> <span lang="ES-TRAD" style="font-size: 10.0pt; line-height: 150%; color: black"> Materiales y métodos</span></b></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><i> <span style="font-size: 10.0pt; line-height: 150%; color: black">Fabricación de  asas:</span></i><span style="font-size: 10.0pt; line-height: 150%; color: black">  Se emplearon segmentos de 20 cm de alambre de níquel-cromo 80:20 Nikrothal 80 (Kanthal)  para construir asas con la misma apariencia de un asa comercial de 10 µL. Para  formar el aro se entorchó el alambre sobre una barra de acero cilíndrica de  diámetro adecuado (mecha de taladro milimétrica). El aro se ajustó a un mango y  de esta manera el asa quedó lista para ser calibrada. </span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><i> <span style="font-size: 10.0pt; line-height: 150%; color: black">Calibración:</span></i><span style="font-size: 10.0pt; line-height: 150%; color: black">  Se utilizaron 4 asas metálicas calibradas comerciales (Copan, California, USA,  Lote 2288, 10 µL, NICROM) y 4 artesanales fabricadas a semejanza de las  comerciales. Para recolectar los inóculos se usó un recipiente de vidrio de 4 cm  de diámetro de boca y 5 cm de altura. La solución empleada para inocular se  colocó en el recipiente. Las asas fueron introducidas en el centro del  recipiente manteniendo el ángulo requerido en cada caso (45º ó 90º), según el  procedimiento reportado [3]. Todas las asas se calibraron por los métodos  gravimétrico y colorimétrico. </span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><i> <span style="font-size: 10.0pt; line-height: 150%; color: black">Método  gravimétrico:</span></i><span style="font-size: 10.0pt; line-height: 150%; color: black">  consistió en transferir con el asa a calibrar inóculos de agua desionizada (Milli  Q plus system, Millipore) tomadas a 45º y 90º de inclinación desde el recipiente  hacia un papel de filtro. Con cada asa y ángulo, fueron tomados 30 inóculos. En  cada ocasión que se transfirió un inóculo se pesó el papel de filtro en una  balanza analítica (Ohaus Adventurer, 0,1 mg)</span><b><span style="font-size: 10.0pt; line-height: 150%; color: red"> </span></b><span style="font-size: 10.0pt; line-height: 150%; color: black">y se  registró la masa en miligramos. Todas las mediciones se realizaron a 25ºC, y se  consideró 1 g/mL la densidad del agua desionizada.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><i> <span style="font-size: 10.0pt; line-height: 150%; color: black">Método  colorimétrico: </span></i> <span style="font-size: 10.0pt; line-height: 150%; color: black">A partir de una  solución comercial de violeta de genciana al 2% en agua (Química Farmacéutica  ALBA-LOF S.A. Caracas - Venezuela) se prepararon 5 patrones diluidos del  colorante con agua desionizada. Se elaboró la curva de calibración de  absorbancia a 588 nm (UV.Vis Espectronic Genesys 2, USA) <i>versus</i>  concentración del colorante. Posteriormente, se colocó 1 mL de agua desionizada  en una cubeta de cuarzo y se colectaron inóculos de solución coloreada con el  asa a ser calibrada a 45 y 90º de inclinación respecto a la superficie del  líquido y se determinó la absorbancia. Se tomaron 12 inóculos para cada asa y  ángulo. Con la curva de calibración se obtuvo la concentración de colorante de  la solución contenida en la cubeta y con este valor se calculó el volumen  inoculado por el aro.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><i> <span style="font-size: 10.0pt; line-height: 150%; color: black">Autocalibración: </span></i><span style="font-size: 10.0pt; line-height: 150%; color: black">Se  construyó una herramienta metálica de doble calibre con dos mechas de taladro de  diferentes diámetros. El diámetro de la mecha más delgada es el mismo de la  barra de acero cilíndrica usada en la fabricación de las asas artesanales. El  asa no calibrada se deslizó por la mecha de menor diámetro y se apretó con un  alicate la base del aro contra la mecha (reformado) y luego se trató de deslizar  el asa por la mecha de mayor diámetro.</span></font><span style="font-size: 10.0pt; line-height: 150%; font-family: Verdana; color: black"> </span><font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Cuando el asa  se deslizó por la mecha más gruesa se repitió el reformado hasta que el aro  adoptó el diámetro de la mecha más delgada.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><i> <span style="font-size: 10.0pt; line-height: 150%; color: black">Análisis  estadístico:</span></i><span style="font-size: 10.0pt; line-height: 150%; color: black">  Una vez finalizada la metodología experimental se organizaron los 672 datos  recabados. El diseño de experimentos utilizado fue completamente aleatorizado  con arreglo factorial de tratamientos 2<sup>3</sup>. Los factores fueron los  siguientes: el método de medida (gravimétrico y colorimétrico), el tipo de asa  utilizada (comercial y artesanal) y el ángulo de carga (45º y 90º), con 4  repeticiones y tomando 30 y 12 inóculos (submuestras) para los métodos  gravimétrico y colorimétrico, respectivamente. Para realizar el análisis  estadístico se emplearon los programas en ambiente Windows SAS® (versión 9.0) y  Minitab (versión 14.3). Se realizaron análisis de varianza, comparación de  medias mediante la prueba de la diferencia honestamente significativa de Tukey,  y finalmente, se determinaron los intervalos de confianza de Bonferroni de las  desviaciones estándar.</span></font></p>     ]]></body>
<body><![CDATA[<p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><b> <span lang="ES-TRAD" style="font-size: 10.0pt; line-height: 150%; color: black"> Resultados</span></b></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">En la <a href="#fig1">figura 1 </a>se puede apreciar el aspecto de las asas fabricadas  artesanalmente. El calibre del alambre de Ni-Cr de las asas artesanales fue  (0,45 ± 0,05) mm y el retorcido sobre la barra de acero cilíndrica generó un aro  con un volumen de 6,14 µL calculado geométricamente. Las asas comerciales poseen  un volumen nominal de 10 µL, no obstante, el volumen de aro calculado  geométricamente es el mismo que el de las asas artesanales.</span></font></p>     <p style="text-align: center; text-autospace: none; vertical-align: middle"> <a name="fig1"><img border="0" src="/img/fbpe/rsvm/v30n1/art08fig1.gif" width="547" height="441"></a></p>     
<p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">En la <a href="#Tabla_1">tabla 1</a> se resumen las significancias estadísticas de las  pruebas de comparación de medias de Tukey realizadas para evaluar el desempeño  de las asas Ni-Cr artesanales y comerciales de acuerdo a varias fuentes de  variación. El análisis estadístico realizado con 672 datos permitió evaluar tres  tipos de efectos: (1) los efectos simples, que consisten en la influencia que  ejerce de forma independiente el método de calibración, el tipo de asa y el  volumen de carga; (2) las interacciones dobles, relativas a las variaciones que  producen las combinaciones: método de calibración–tipo de asa, método de  calibración–ángulo de carga y tipo de asa–ángulo de carga; y (3) la interacción  triple, que permite detectar variaciones debidas a la conjugación de las tres  fuentes de variación. </span></font></p>     <p style="text-align: center"><font face="Verdana" size="2"> <span style="color: black"><b><a name="Tabla_1">Tabla 1</a>.</b> Comparación de  los volúmenes de carga de las asas mediante la prueba de medias de Tukey.</span></font></p>     <div align="center">   <table class="MsoNormalTable" border="1" cellspacing="0" cellpadding="0" style="border-collapse: collapse; border: medium none; margin-left: 5.4pt" id="table1" width="500">     <tr style="height: 21.0pt">       <td width="205" style="width: 153.75pt; height: 21.0pt; border: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           <p align="center" style="text-align: center; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span lang="EN-US" style="color: black">       Fuente de variación</span></font></td>       <td width="109" style="width: 81.85pt; height: 21.0pt; border-left: medium none; border-right: 1.0pt solid black; border-top: 1.0pt solid black; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           <p align="center" style="text-align: center; text-autospace: none; vertical-align: middle">       <font face="Verdana"><i><span lang="EN-US" style="color: black">       <font size="2">p</font></span></i><span lang="EN-US" style="color: black"><font size="2">-valor</font><sup><font size="2">a</font></sup></span></font></td>     </tr>     <tr style="height: 16.6pt">       <td width="205" style="width: 153.75pt; height: 16.6pt; border-left: 1.0pt solid black; border-right: 1.0pt solid black; border-top: medium none; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           <p style="text-align: center; text-indent: 14.15pt; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span lang="EN-US" style="color: black">       Ángulo de carga</span></font></td>       <td width="109" style="width: 81.85pt; height: 16.6pt; border-left: medium none; border-right: 1.0pt solid black; border-top: medium none; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           <p align="center" style="text-align: center; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span lang="EN-US" style="color: black">       &lt;0,0001</span></font></td>     </tr>     <tr style="height: 16.6pt">       <td width="205" style="width: 153.75pt; height: 16.6pt; border-left: 1.0pt solid black; border-right: 1.0pt solid black; border-top: medium none; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           ]]></body>
<body><![CDATA[<p style="text-align: center; text-indent: 14.15pt; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span lang="EN-US" style="color: black">       Método de calibración</span></font></td>       <td width="109" style="width: 81.85pt; height: 16.6pt; border-left: medium none; border-right: 1.0pt solid black; border-top: medium none; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           <p align="center" style="text-align: center; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span lang="EN-US" style="color: black">       &lt;0,0001</span></font></td>     </tr>     <tr style="height: 16.6pt">       <td width="205" style="width: 153.75pt; height: 16.6pt; border-left: 1.0pt solid black; border-right: 1.0pt solid black; border-top: medium none; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           <p style="text-align: center; text-indent: 14.15pt; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span lang="EN-US" style="color: black">Tipo        de asa</span></font></td>       <td width="109" style="width: 81.85pt; height: 16.6pt; border-left: medium none; border-right: 1.0pt solid black; border-top: medium none; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           <p align="center" style="text-align: center; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span lang="EN-US" style="color: black">       0,0003</span></font></td>     </tr>     <tr style="height: 16.6pt">       <td width="205" style="width: 153.75pt; height: 16.6pt; border-left: 1.0pt solid black; border-right: 1.0pt solid black; border-top: medium none; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           <p style="text-align: center; text-indent: 14.15pt; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span lang="EN-US" style="color: black">       Método – tipo de asa<sup>b</sup></span></font></td>       <td width="109" style="width: 81.85pt; height: 16.6pt; border-left: medium none; border-right: 1.0pt solid black; border-top: medium none; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           <p align="center" style="text-align: center; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span lang="EN-US" style="color: black">       0,5793</span></font></td>     </tr>     <tr style="height: 16.6pt">       <td width="205" style="width: 153.75pt; height: 16.6pt; border-left: 1.0pt solid black; border-right: 1.0pt solid black; border-top: medium none; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           <p style="text-align: center; text-indent: 14.15pt; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span lang="EN-US" style="color: black">       Método – ángulo<sup>b</sup></span></font></td>       <td width="109" style="width: 81.85pt; height: 16.6pt; border-left: medium none; border-right: 1.0pt solid black; border-top: medium none; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           <p align="center" style="text-align: center; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span lang="EN-US" style="color: black">       0,8394</span></font></td>     </tr>     <tr style="height: 16.6pt">       <td width="205" style="width: 153.75pt; height: 16.6pt; border-left: 1.0pt solid black; border-right: 1.0pt solid black; border-top: medium none; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           <p style="text-align: center; text-indent: 14.15pt; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span lang="EN-US" style="color: black">Tipo        de asa – ángulo<sup>b</sup> </span></font></td>       <td width="109" style="width: 81.85pt; height: 16.6pt; border-left: medium none; border-right: 1.0pt solid black; border-top: medium none; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           <p align="center" style="text-align: center; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span lang="EN-US" style="color: black">       0,3060</span></font></td>     </tr>     <tr style="height: 16.6pt">       <td width="205" style="width: 153.75pt; height: 16.6pt; border-left: 1.0pt solid black; border-right: 1.0pt solid black; border-top: medium none; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           ]]></body>
<body><![CDATA[<p style="text-align: center; text-indent: 14.15pt; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span style="color: black">Método – tipo de        asa – ángulo<sup>b</sup></span></font></td>       <td width="109" style="width: 81.85pt; height: 16.6pt; border-left: medium none; border-right: 1.0pt solid black; border-top: medium none; border-bottom: 1.0pt solid black; padding-left: 5.4pt; padding-right: 5.4pt; padding-top: 0cm; padding-bottom: 0cm">           <p align="center" style="text-align: center; text-autospace: none; vertical-align: middle">       <font face="Verdana" size="2"><span lang="EN-US" style="color: black">       0,1164</span></font></td>     </tr>   </table> </div>     <p align="justify"><font face="Verdana"><sup><span style="color: black"> <font size="2">a </font></span></sup><span style="color: black"><font size="2"> Se considera significativo un <i>p</i>-valor &#8804; 0,05.</font></span></font></p>     <p style="margin-right:280.3pt"><font face="Verdana"><sup> <span style="color: black"><font size="2">b </font></span></sup> <span style="color: black"><font size="2">Estos casos constituyen interacciones  de las dos o tres fuentes de variación.</font></span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">La prueba de  comparación de medias de Tukey establece que hay diferencias altamente  significativas en cuanto al ángulo de carga (p&lt;0,0001), el método de calibración  (p&lt;0,0001) y el tipo de asa (p&lt;0,0003). En la <a href="#fig2">figura 2 </a>se  pueden observar en forma comparativa los volúmenes inoculados de las asas de  acuerdo a diferentes fuentes de variación y sus respectivas desviaciones  estándar, en función de las fuentes de variación mencionadas anteriormente. </span></font></p>     <p style="text-align: center; text-autospace: none; vertical-align: middle"> <a name="fig2"><img border="0" src="/img/fbpe/rsvm/v30n1/art08fig2.gif" width="576" height="323"></a></p>     
<p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Con respecto al  ángulo de carga, se observa (<a href="#fig2">Figura 2A</a>) claramente que al  realizar el muestreo a 45º de inclinación respecto a la superficie del líquido,  el volumen promedio global de las asas casi duplica al correspondiente tomado a  90º. Esto refleja una fuerte dependencia del ángulo de carga con respecto al  volumen que las asas en general retienen. Los volúmenes a 45º tienden a  aproximarse al volumen calculado geométricamente (6,14 </span></font> <span lang="EN-US" style="font-size: 10.0pt; line-height: 150%; font-family: Verdana; color: black"> m</span><font face="Verdana"><span style="font-size: 10.0pt; line-height: 150%; color: black">L),  en consecuencia son significativamente menores a 10 </span></font> <span lang="EN-US" style="font-size: 10.0pt; line-height: 150%; font-family: Verdana; color: black"> m</span><font face="Verdana"><span style="font-size: 10.0pt; line-height: 150%; color: black">L;  este último es el volumen que el fabricante atribuye a sus asas comerciales.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">En cuanto al  método de calibración, se observa (<a href="#fig2">Figura 2B</a>) que el método  colorimétrico tiende a indicar un volumen ligeramente superior al que es medido  por el método gravimétrico (la diferencia es alrededor de 0,63 </span></font> <span lang="EN-US" style="font-size: 10.0pt; line-height: 150%; font-family: Verdana; color: black"> m</span><font face="Verdana"><span style="font-size: 10.0pt; line-height: 150%; color: black">L).  Si bien la prueba de Tukey arroja que la diferencia es muy significativa, con  fines prácticos, el comportamiento de los dos métodos de calibración es bastante  homogéneo. Por otra parte, es natural que las medias en este caso se ubiquen  alrededor de 5 </span></font> <span lang="EN-US" style="font-size: 10.0pt; line-height: 150%; font-family: Verdana; color: black"> m</span><font face="Verdana"><span style="font-size: 10.0pt; line-height: 150%; color: black">L  dado que cada media incluye a datos de los dos ángulos de carga.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">En lo que se  refiere al tipo de asa (<a href="#fig2">Figura 2C</a>), se establece que las  asas artesanales toman un volumen ligeramente superior al correspondiente de las  asas comerciales, la diferencia entre ambas asas es apenas 0,56 </span></font> <span lang="EN-US" style="font-size: 10.0pt; line-height: 150%; font-family: Verdana; color: black"> m</span><font face="Verdana"><span style="font-size: 10.0pt; line-height: 150%; color: black">L,  nuevamente para propósitos prácticos, el comportamiento de ambos tipos de asas  es bastante homogéneo.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Las  interacciones de dos y tres fuentes de variación no generaron diferencias  significativas a través de la prueba de medias de Tukey (<a href="#Tabla_1">Tabla  1</a>).</span></font></p>     ]]></body>
<body><![CDATA[<p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">En la <a href="#fig3">figura 3</a> se pueden apreciar las medias de los volúmenes de  las asas de Ni-Cr desglosados de acuerdo al método de calibración, ángulo de  carga, tipo de asa y las respectivas desviaciones estándar. En todos los casos  las asas artesanales toman un volumen mayor; sin embargo, tales volúmenes no son  significativamente diferentes. La <a href="#fig3">figura 3</a> muestra  nuevamente que sin importar el método de calibración y el tipo de asa, los  volúmenes muestreados a 45º son bastantes mayores que los respectivos valores a  90º, pero más próximos a 6,14 </span></font> <span lang="EN-US" style="font-size: 10.0pt; line-height: 150%; font-family: Verdana; color: black"> m</span><font face="Verdana"><span style="font-size: 10.0pt; line-height: 150%; color: black">L  (el volumen geométrico de todas las asas) que a 10 </span></font> <span lang="EN-US" style="font-size: 10.0pt; line-height: 150%; font-family: Verdana; color: black"> m</span><font face="Verdana"><span style="font-size: 10.0pt; line-height: 150%; color: black">L  (el volumen nominal indicado por el fabricante de las asas comerciales).</span></font></p>     <p style="text-align: center; text-autospace: none; vertical-align: middle"> <a name="fig3"><img border="0" src="/img/fbpe/rsvm/v30n1/art08fig3.gif" width="579" height="323"></a></p>     
<p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">La precisión de  las asas se valoró mediante los intervalos de confianza de Bonferroni (<a href="#fig4">Figura  4</a>). Las desviaciones estándar son bajas y no superan la unidad; esto es  concordante con el coeficiente de variación (%CV) global del experimento,  ubicado en 11%, lo que significa que las asas tienden a medir el mismo volumen  de forma reproducible. Los intervalos de confianza de Bonferroni, los cuales son  indicados por las barras de error de la <a href="#fig4">figura 4 </a>se muestran  bastante homogéneos entre sí. Sin embargo, en general los intervalos de  confianza de las asas calibradas por el método colorimétrico son mayores que los  correspondientes al método gravimétrico, evidenciando que la calibración  gravimétrica tiende a ser más precisa.</span></font></p>     <p style="text-align: center; text-autospace: none; vertical-align: middle"> <a name="fig4"><img border="0" src="/img/fbpe/rsvm/v30n1/art08fig4.gif" width="567" height="321"></a></p>     
<p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><b> <span lang="ES-TRAD" style="font-size: 10.0pt; line-height: 150%; color: black"> Discusión</span></b></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Los resultados  reseñados en este estudio muestran que las asas de Ni-Cr, fabricadas  artesanalmente, tienen similar apariencia y se desempeñan de igual forma que las  asas de procedencia comercial, fabricadas con la misma aleación.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Con respecto al  ángulo de carga, Sarvin <i>et al</i> [10] afirman que la carga de un asa a 90º  produce un valor menor que a ángulos inferiores. Esto es consistente con los  datos observados en este estudio. Otro trabajo justifica que la masa de líquido  recolectada en el aro de un asa cuando éste se encuentra en posición vertical es  menor debido al efecto de la gravedad y a la menor interacción del  líquido-superficie del aro [11].</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Los volúmenes  de las asas, incluso las comerciales, son definitivamente menores a 10 </span> </font> <span lang="EN-US" style="font-size: 10.0pt; line-height: 150%; font-family: Verdana; color: black"> m</span><font face="Verdana"><span style="font-size: 10.0pt; line-height: 150%; color: black">L  si se usan ángulos de carga de 45º ó 90º. Dado que es muy poca la información  disponible sobre los métodos o protocolos de fabricación y calibración de las  asas comerciales, no está clara cuál es la justificación de asignar volúmenes de  10 µL a asas fabricadas comercialmente cuya geometría indica que el volumen  teórico de carga es 6,14 µL.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Basados en los  resultados expuestos en este trabajo y conforme a la literatura [1], no es  prudente aceptar las especificaciones de asas que dan por sentado que el volumen  de muestra tomado es igual al volumen nominal del asa que indica el fabricante,  dado que existen varios factores que afectan la carga que toma un asa  determinada. Entre</span><span style="font-size: 10.0pt; line-height: 150%; color: white"> </span><span style="font-size: 10.0pt; line-height: 150%; color: black">ellos  están el tipo de material del asa (la tensión interfacial muestra líquida-asa),  la viscosidad de la solución empleada para inocular, densidad del inóculo,  tamaño del recipiente de la muestra y ángulo de carga, entre otras variables  [1,10,11].</span><span style="font-size: 10.0pt; line-height: 150%; color: white"> </span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Se ha reportado  que la toma horizontal de muestra (ángulo de 0º) con asas de 1 </span> <span lang="EN-US" style="font-size: 10.0pt; line-height: 150%; color: black">&#956;</span><span style="font-size: 10.0pt; line-height: 150%; color: black">L  resulta en un volumen inoculado que es el doble de aquel cuando la muestra es  recolectada a un ángulo de 90º [12]. En este trabajo, la tendencia de los  volúmenes tomados a 45º y 90º permite inferir que a 0º los volúmenes de carga de  las asas artesanales y comerciales podría superar el doble de los valores que se  consiguen a 90º. Por lo tanto, el ángulo con el que se carga el asa, es  claramente un factor determinante en el volumen que ésta cargará. Es interesante  destacar que el personal del laboratorio clínico, de investigación y de docencia  muestrea con las asas a 90º como práctica común, sin que exista una razón  sustentada. Las conclusiones que se desprenden de este estudio apuntan a un  cambio en la forma en que se toma la muestra con estos instrumentos o a un  ajuste en el volumen de asa que se considera para los cálculos posteriores.</span></font></p>     ]]></body>
<body><![CDATA[<p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Es evidente el  efecto que el ángulo de carga tiene sobre el volumen inoculado y la toma de  inóculos a 90º implica muestreo por defecto, y en muchos casos podría llegar a  obtenerse un contaje de microorganismos por debajo de la cantidad real,  pudiéndose llegar a la conclusión errónea de asegurar la ausencia significante  de patógenos en la muestra.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">El método  colorimétrico ha sido recomendado para aquellos casos en los cuales una medida  directa de masa no pueda efectuarse [1, 3, 5, 12] como en el caso de asas de 1  µL. Aunque se ha demostrado que la calibración colorimétrica conduce a volúmenes  ligeramente superiores a los de la calibración gravimétrica, con fines prácticos  los métodos pueden ser considerados intercambiables; no obstante se sugiere para  asas de volúmenes superiores a 1 </span></font> <span lang="EN-US" style="font-size: 10.0pt; line-height: 150%; font-family: Verdana; color: black"> m</span><font face="Verdana"><span style="font-size: 10.0pt; line-height: 150%; color: black">L  optar por el método gravimétrico, el cual es un método directo menos laborioso  (el método colorimétrico requiere más pasos para su ejecución) y además los  intervalos de Bonferroni sugieren que la calibración gravimétrica conlleva mayor  precisión.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">La  autocalibración se refiere a la calibración intrínseca que el método de  fabricación lleva consigo. Con base en los resultados de estos experimentos, es  evidente que todas las asas fabricadas de manera artesanal inoculan el volumen  de muestra de manera bastante exacta y precisa respecto a las asas comerciales.  Por lo antes expuesto queda en evidencia que un asa artesanal, fabricada con una  herramienta apropiada y bajo los controles de fabricación establecidos en el  protocolo, puede considerarse “calibrada” en función del volumen geométrico.  Este volumen tendrá un error de ±1 </span> <span lang="EN-US" style="font-size: 10.0pt; line-height: 150%; color: black">&#956;</span><span style="font-size: 10.0pt; line-height: 150%; color: black">L  para un asa considerada nominalmente de 10 µL. Por otra parte, con el uso de la  herramienta metálica de doble calibre se pueden recalibrar las asas cada vez que  éstas lo ameriten, de forma rápida y sencilla.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Finalmente, la  fabricación artesanal de las asas por nuestro método ofrece ventajas económicas  frente a la importación. El costo de las asas sería aproximadamente la mitad del  precio de catálogo de las asas de un fabricante internacional conocido [13], sin  tomar en cuenta que la adquisición del producto importado además debe incluir  los costos de envío y nacionalización, en cuyo caso el valor de las asas  artesanales podría representar cerca de un tercio del costo de sus equivalentes  comerciales.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">De este estudio  entonces se desprende que (1) todas las asas se ven afectadas por el ángulo de  carga, (2) ambos grupos de asas (comerciales y artesanales) se desempeñan de  forma idéntica, (3)</span><b><span style="font-size: 10.0pt; line-height: 150%; color: red"> </span></b><span style="font-size: 10.0pt; line-height: 150%; color: black">los  métodos de calibración gravimétrico y colorimétrico prácticamente se comportan  de la misma forma y (4) la fabricación de asas de metal por el método aquí  descrito, es una tarea de fácil ejecución y de bajo costo.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><b> <span lang="ES-TRAD" style="font-size: 10.0pt; line-height: 150%; color: black"> Agradecimientos</span></b></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"> <span style="font-size: 10.0pt; line-height: 150%; color: black">Los autores  agradecen a Fundacite Aragua y a la Empresa Techomat C.A. por el financiamiento  de este trabajo.</span></font></p>     <p style="text-align: justify; text-autospace: none; vertical-align: middle"> <font face="Verdana"><b> <span lang="EN-US" style="font-size: 10.0pt; line-height: 150%; color: black"> Referencias</span></b></font></p>     <!-- ref --><p style="line-height: 100%"><font face="Verdana" size="2"> <span lang="EN-US" style="line-height: 150%">1. Albers AC, Fletcher RD. Simple  method for quantitation of viable micoplasma. Appl Environ Microbiol.<i> </i> 1982;<i> </i>43(4):958-60. </span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2006927&pid=S1315-2556201000010000800001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%"><font face="Verdana" size="2"> <span lang="EN-US" style="line-height: 150%">2. Burri P. The quantitative  smear-culture: a simple means for bacteriological examination of milk World  Dairy Congress<i>.</i> 1928.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2006928&pid=S1315-2556201000010000800002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%"><font face="Verdana"> <span lang="EN-US" style="line-height: 150%"><font size="2">3. Jacobs JA, De  Brauwer E, Cornelissen E, Drent M. Accuracy and precision of quantitative  calibrated loops in transfer of bronchoalveolar lavage fluid. J Med Microbiol.  2000; 38: 2117-21.</font></span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2006929&pid=S1315-2556201000010000800003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%"><font face="Verdana"> <span lang="EN-US" style="line-height: 150%"><font size="2">4. Barry AL, Smith  P, Turck M. Cumitech 2. Laboratory diagnosis of urinary tract infections.  American Society for Microbiology</font><i><font size="2">.</font></i></span><span lang="EN-US" style="line-height: 150%; color: #333333"><font size="2">  Washington, D.C.</font></span></font><span lang="EN-US" style="line-height: 150%; font-family: Verdana; color: #333333"><font size="2"> </font></span><font face="Verdana" size="2"> <span lang="EN-US" style="line-height: 150%">1975; 28:150-90.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2006930&pid=S1315-2556201000010000800004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%"><font face="Verdana" size="2"> <span lang="EN-US" style="line-height: 150%">5. Frimodt-Moller N, Espersen F.  Evaluation of calibrated 1 and 10 microl loops and dipslide as compared to  pipettes for detection of low count bacteriuria in vitro. APMIS. 2000;  30:525-30. </span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2006931&pid=S1315-2556201000010000800005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%"><font face="Verdana"> <span lang="EN-US" style="line-height: 150%"><font size="2">6. Jacobs JA,  Stobberingh EE, Drent M, Cornelissen E. Detection of <i>Streptococcus pneumoniae</i>  antigen in bronchoalveolar lavage fluid samples by a rapid inmunochromatographic  membrane assay. J Med Microbiol. 2005; 43:4037-40.</font></span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2006932&pid=S1315-2556201000010000800006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%"><font face="Verdana" size="2"> <span lang="EN-US" style="line-height: 150%">7. Deldari M. Designing a new  programme for calibration of bacteriological loops. Clin Microbiol Infect. 2000;  26:903-16.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2006933&pid=S1315-2556201000010000800007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%"><font face="Verdana" size="2"> <span lang="EN-US" style="line-height: 150%">8. Skoog DA. Principles of  Instrumental Analysis.<i> </i>New York: Holt, Rinehart and Winston; 1971.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2006934&pid=S1315-2556201000010000800008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%"><font face="Verdana"> <span lang="EN-US" style="line-height: 150%"><font size="2">9. Wong J. Gauge for  validating the calibration of a loop. </font></span> <span lang="ES-TRAD" style="line-height: 150%"><font size="2">En: <a href="http://www.sciloops.com/cilg.html">http://www.sciloops.com/cilg.html</a>.</span><span style="line-height: 150%"> </span><span lang="ES-TRAD" style="line-height: 150%">Acceso 26 de septiembre de  2007.</span></font></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2006935&pid=S1315-2556201000010000800009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%"><font face="Verdana" size="2"> <span lang="EN-US" style="line-height: 150%">10. Sarvin P, Kamal K, Dinesh S,  Joseph D. Effect of surfactant concentration and film area on the stability of  films of surfactant solutions. J Colloid Interface Sci<i>. </i>1996; 32:564-78.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2006936&pid=S1315-2556201000010000800010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%"><font face="Verdana" size="2"> <span lang="EN-US" style="line-height: 150%">11. Shaw DJ. Colloid and Surface  Chemistry. 4<sup>a</sup> ed. Gran Bretaña: Butterworth-Heinemann Ltd; 1992.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2006937&pid=S1315-2556201000010000800011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p style="line-height: 100%"><font face="Verdana"> <span lang="EN-US" style="line-height: 150%"><font size="2">12. Jaugen J., Strom  O, Ostervold A. Bacterial counts in urine: The reliability of the loop  technique. </font></span><span lang="ES-TRAD" style="line-height: 150%"> <font size="2">Acta Pathol Microbiol Scand<i>.</i> 1968;<i> </i>74:391-6.</font></span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2006938&pid=S1315-2556201000010000800012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify" style="line-height: 100%"><font face="Verdana" size="2"> <span style="line-height: 150%; color: black">13. </span> <span lang="ES-TRAD" style="line-height: 150%; color: black">Costo de una asa  calibrada de niquel-cromo de 10 </span></font> <span lang="ES-TRAD" style="line-height: 150%; font-family: Verdana; color: black"> <font size="2">m</font></span><font face="Verdana" size="2"><span lang="ES-TRAD" style="line-height: 150%; color: black">L  de un conocido fabricante internacional. <a href="https://www.vwrsp.com/catalog/product/index.cgi?catalog_number=30002-142&inE=1&highlight=30002-142"> https://www.vwrsp.com/catalog/product/index.cgi?catalog_number=30002-142</a></span><a href="https://www.vwrsp.com/catalog/product/index.cgi?catalog_number=30002-142&inE=1&highlight=30002-142"><span style="line-height: 150%"> </span><span lang="ES-TRAD" style="line-height: 150%">&amp;</span><span style="line-height: 150%"> </span><span lang="ES-TRAD" style="line-height: 150%">inE=1</span><span style="line-height: 150%"> </span><span lang="ES-TRAD" style="line-height: 150%">&amp;</span><span style="line-height: 150%"> </span><span lang="ES-TRAD" style="line-height: 150%">highlight=30002-142</span></a><span lang="ES-TRAD" style="line-height: 150%; color: black">.</span><span style="line-height: 150%; color: black"> </span><span lang="ES-TRAD" style="line-height: 150%; color: black">Acceso 14 de  mayo 2010.</span></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2006939&pid=S1315-2556201000010000800013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body>
<back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Albers]]></surname>
<given-names><![CDATA[AC]]></given-names>
</name>
<name>
<surname><![CDATA[Fletcher]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Simple method for quantitation of viable micoplasma]]></article-title>
<source><![CDATA[Appl Environ Microbiol.]]></source>
<year>1982</year>
<volume>43</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>958-60</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Burri]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<source><![CDATA[The quantitative smear-culture: a simple means for bacteriological examination of milk World Dairy Congress]]></source>
<year>1928</year>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jacobs]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[De Brauwer]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Cornelissen]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Drent]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Accuracy and precision of quantitative calibrated loops in transfer of bronchoalveolar lavage fluid]]></article-title>
<source><![CDATA[J Med Microbiol.]]></source>
<year>2000</year>
<volume>38</volume>
<page-range>2117-21</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barry]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Turck]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Cumitech 2. Laboratory diagnosis of urinary tract infections]]></source>
<year>1975</year>
<volume>28</volume>
<page-range>150-90</page-range><publisher-loc><![CDATA[Washington^eD.C D.C]]></publisher-loc>
<publisher-name><![CDATA[American Society for Microbiology]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Frimodt-Moller]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Espersen]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of calibrated 1 and 10 microl loops and dipslide as compared to pipettes for detection of low count bacteriuria in vitro]]></article-title>
<source><![CDATA[APMIS.]]></source>
<year>2000</year>
<volume>30</volume>
<page-range>525-30</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jacobs]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Stobberingh]]></surname>
<given-names><![CDATA[EE]]></given-names>
</name>
<name>
<surname><![CDATA[Drent]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Cornelissen]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Detection of Streptococcus pneumoniae antigen in bronchoalveolar lavage fluid samples by a rapid inmunochromatographic membrane assay]]></article-title>
<source><![CDATA[J Med Microbiol.]]></source>
<year>2005</year>
<volume>43</volume>
<page-range>4037-40</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Deldari]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Designing a new programme for calibration of bacteriological loops]]></article-title>
<source><![CDATA[Clin Microbiol Infect.]]></source>
<year>2000</year>
<volume>26</volume>
<page-range>903-16</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Skoog]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
</person-group>
<source><![CDATA[Principles of Instrumental Analysis]]></source>
<year>1971</year>
<publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[Holt, Rinehart and Winston]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wong]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Gauge for validating the calibration of a loop]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sarvin]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Kamal]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Dinesh]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Joseph]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of surfactant concentration and film area on the stability of films of surfactant solutions]]></article-title>
<source><![CDATA[J Colloid Interface Sci.]]></source>
<year>1996</year>
<volume>32</volume>
<page-range>564-78</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shaw]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
</person-group>
<source><![CDATA[Colloid and Surface Chemistry]]></source>
<year>1992</year>
<edition>4ª</edition>
<publisher-loc><![CDATA[Gran Bretaña ]]></publisher-loc>
<publisher-name><![CDATA[Butterworth-Heinemann Ltd]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jaugen]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Strom]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Ostervold]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bacterial counts in urine: The reliability of the loop technique]]></article-title>
<source><![CDATA[Acta Pathol Microbiol Scand.]]></source>
<year>1968</year>
<volume>74</volume>
<page-range>391-6</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="">
<source><![CDATA[Costo de una asa calibrada de niquel-cromo de 10 mL de un conocido fabricante internacional]]></source>
<year></year>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>