SciELO - Scientific Electronic Library Online

 
vol.63 número3Calcinosis escrotal idiopática: Reporte de un caso.Evaluación de actividad física como coadyuvante terapéutico para pacientes con enfermedad inflamatoria intestinal: una revisión. índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Investigación Clínica

versión impresa ISSN 0535-5133versión On-line ISSN 2477-9393

Resumen

CHEN, Sheng; JIA, Jieshuang; GUO, Huimin  y  ZHU, Nan. The benefits of peritoneal dialysis (PD) solution with low-glucose degradation product in residual renal function and dialysis adequacy in PD patients: A meta-analysis. Invest. clín [online]. 2022, vol.63, n.3, pp.283-303.  Epub 18-Abr-2023. ISSN 0535-5133.  https://doi.org/10.54817/ic.v63n3a07.

The peritoneal effects of low-glucose degradation product (GDP)-containing peritoneal dialysis (PD) solutions have been extensively described. To systematically evaluate the efficacy and safety of low GDP solution for PD patients, specifically the effect on residual renal function (RRF) and dialysis adequacy, we conducted a meta-analysis of the published randomized controlled trials (RCTs). Different databases were searched for RCTs that compared low GDP-PD solutions with conventional PD solutions in the treatment of PD patients with continuous ambulatory peritoneal dialysis (CAPD) and automated peritoneal dialysis (APD). The outcomes of RCTs should include RRF and may include small solute clearance, peritoneal transport status, nutritional status, and all-cause mortality. Seven studies (632 patients) were included. Compared with the conventional solution, low-GDP solution preserved RRF in PD patients over time (MD 0.66 mL/min, 95% CI 0.34 to 0.99; p<0.0001), particularly in one year of treatment (p<0.01), and improved weekly Kt/V (MD 0.11, 95% CI 0.05 to 0.17; p=0.0007) without an increased 4-hour D/Pcr (MD 0.00, 95% CI -0.02 to 0.02; p=1.00). Notably, the MD of RRF and urine volume between the two groups tended to decrease as time on PD progressed up to 24 months. Patients using low GDP PD solutions did not have an increased risk of all-cause mortality (MD 0.97, 95% CI 0.50 to 1.88; p=0.93). Our meta-analysis confirms that the low GDP PD solution preserves RRF, improves the dialysis adequacy without increasing the peritoneal solute transport rate and all-cause mortality. Further trials are needed to determine whether this beneficial effect can affect long-term clinical outcomes.

Palabras clave : glucose degradation products; peritoneal dialysis solution; residual renal function; dialysis adequacy; meta-analysis.

        · resumen en Español     · texto en Inglés     · Inglés ( pdf )