SciELO - Scientific Electronic Library Online

 
vol.73 suppl.1P310/S5-P55 LACTANCIA FAMILIAR - CONSEJERÍA A PERSONAS TRANSGÉNERO Y NO BINARIAS LACTANTESP312/S5-P57 INDICADORES SOCIODEMOGRÁFICOS, CLÍNICOS Y DIETA EN UN GRUPO DE ADULTOS MAYORES CUBANOS SEGÚN DETERIORO COGNITIVO índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Archivos Latinoamericanos de Nutrición

versão impressa ISSN 0004-0622versão On-line ISSN 2309-5806

Arch Latinoam Nutr vol.73  supl.1 Caracas out. 2023  Epub 29-Jan-2025

 

Comunicaciones - Pósters

P311/S5-P56 EXPOSURE TO ULTRA-PROCESSED FOODS DURING PREGNANCY AND ULTRASOUND FETAL GROWTH PARAMETERS

Dra. Bárbara H. Lourenço1 

Prof. Marcia C. Castro2 

Dra. Priscila M. Sato3 

Dr. Paulo A. R. Neves4 

Dr. Edwin Vivanco5 

Dr. Daniel L. Lima5 

Prof. Marly A. Cardoso1 

1Universidade de São Paulo, São Paulo, Brazil.

2Harvard T.H. Chan School of Public Health, Boston, MA, USA.

3Universidade Federal da Bahia, Salvador, Brazil.

4University of Toronto, Toronto, ON, Canada.

5Hospital da Mulher e da Criança do Juruá, Cruzeiro do Sul, Brazil.


Abstract:

Introduction:

Periconceptional maternal ultra-processed food (UPF) consumption impairs embryonic growth. Impacts of exposure to UPF on distinct components of fetal growth in late pregnancy are unknown.

Objective:

To investigate the influence of frequency of UPF consumption during pregnancy on fetal head circumference (HC), abdominal circumference (AC), and femur length (FL).

Methods:

This study included 417 live-born singleton pregnancies prospectively followed-up since the antenatal period in the MINA-Brazil Study (Maternal and Child Health and Nutrition in Acre, Brazil), with an available ultrasound scan at >24 gestational weeks. Frequency of food groups consumption in the previous month was categorized as no/monthly, weekly, or daily. Ultrasound scans were conducted at 27.8 (SD: 1.7) gestational weeks. HC, AC, and FL z-scores were calculated for gestational age using the INTERGROWTH-21st Project standards. Simultaneous-quantile regression models were fitted at the 10th, 50th, and 90th percentiles of the distribution of each ultrasound parameter according to UPF consumption, with adjustment for potential confounders.

Results:

Participants were aged on average 24.7 (SD: 6.5) years, 44.8% were primiparous, and 26.9% and 24.9%, respectively, had weekly and daily UPF consumption. Compared to no/ monthly intake, daily UPF consumption impaired HC across its distribution, with significant effect sizes varying from -0.24 to -0.40 z-score. Weekly UPF consumption decreased HC at the 90th percentile by -0.39 z-score (95% CI: -0.78, -0.01) and FL at the 50th percentile by -0.32 z-score (95% CI: -0.60, -0.04). No association was noted with AC.

Conclusion:

Frequency of UPF consumption was negatively associated with skeletal components of fetal growth in late pregnancy. Infant body composition may benefit from healthy food practices since pregnancy.

Keywords: fetal growth; pregnancy; ultra-processed foods; ultrasound

Creative Commons License This is an open-access article distributed under the terms of the Creative Commons Attribution License